Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Power Electronics: FS3000K {600V} — CEC Inverter Specifications

Manufacturer: Power Electronics Registry: CEC Verified Engineering Specification

Power Electronics: FS3000K {600V} outputs 3,121,310 W AC at 600 V, 3-phase (3003.6 A continuous, 3,800 A OCPD), ranking #386 of 2,343 CEC inverters at 97.89% efficiency with a 849-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
3,121,310 W
AC Voltage
600 V, 3-phase
Min PV Breaker
3,800 A (parallel Cu feeders)
CEC Efficiency
97.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Power Electronics: FS3000K {600V} Compare Against Peer CEC Listings?

Breaker sizing (3,800 A), parallel Cu feeders wire rules, and DC input limits for Power Electronics: FS3000K {600V}.

For NEC 705.12 solar interconnection, Power Electronics: FS3000K {600V} outputs 3003.6 A continuous AC at 600 V, 3-phase and needs a 3,800 A backfeed breaker on parallel Cu feeders (75 C). Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap. Conversion efficiency scores 97.89% (#386 of 2,343, +1.07 pts vs overall CEC median).

Where Does Power Electronics: FS3000K {600V} Fall Across Listed CEC Models?

Output power comparison showing where Power Electronics: FS3000K {600V} sits among all 2,343 CEC-listed grid-support inverters. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Power Electronics: FS3000K {600V} (3,121,310 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACPower Electronics:: 3,121,310 W

What Dataset Percentiles Define Power Electronics: FS3000K {600V}?

Relative ranking of Power Electronics: FS3000K {600V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Power Electronics: FS3000K {600V} Technical ThresholdsPercentile comparison for Power Electronics: FS3000K {600V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output3,121,310 WCEC Efficiency97.89%Backfeed Breaker3,800 A

What Do the Dataset Ranks Show for Power Electronics: FS3000K {600V}?

Snapshot of Power Electronics: FS3000K {600V} efficiency rank (#386), OCPD breaker size, MPPT span, and busbar verdict. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Eff #386 / 2,343

97.89% CEC Weighted Efficiency

-0.39 pts vs the 98.28% 600 V median; overall power rank #48 (3,121,310 W, top 2.0%; higher than 98.0% of peers).

NEC 705.12 Check

3,800 A Required Backfeed OCPD

125% x 3003.6 A = 3754.5 A -> 3,800 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

849 V - 1,200 V (Max 1,200 V DC)

Tracking span of 351.0 V; active in CEC directory (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3121310.0W / 600 V 3-phase -> 3003.6 A | Breaker >= 1.25 * 3003.6 = 3754.5 A -> 3,800 A

CEC Inverters.csv for Power Electronics: FS3000K {600V}: Paco=3121310.0 W, Vac=600 V, Vdcmax=1200.0 V, Eff=97.89%.

Result: Min 3,800 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (600V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Power Electronics: FS3000K {600V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Power Electronics: FS3000K {600V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Power Electronics: FS3000K {600V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 3,121,310 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 600 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 849 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 3392.14 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.89% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Power Electronics: FS3000K {600V} (600 V, 3-phase)?

NEC 705.12(B)(3)(2) backfeed compliance table for Power Electronics: FS3000K {600V} at 600 V, 3-phase. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Evaluates Power Electronics: FS3000K {600V} (3800 A required OCPD at 600 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (600V) 40 A 3,800 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (600V) 80 A 3,800 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (600V) 120 A 3,800 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (600V) 160 A 3,800 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (600V) 240 A 3,800 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With Power Electronics: FS3000K {600V}?

Minimum and maximum series solar module strings fitting Power Electronics: FS3000K {600V} MPPT and 1,200 V limits. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sampled CEC PV modules aligned within 849.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 20 to 21 panels 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 26 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 25 to 26 panels 11.05 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 21 to 22 panels 11.33 kW

Which Competing Grid-Support Inverters Compare to Power Electronics: FS3000K {600V}?

Peer 600 V, 3-phase CEC inverters near 3,121,310 W AC output such as INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}
INGETEAM POWER TECHNOLOGY SA
3,095,300 W -26010 W 600.0 V 1300.0 V 97.54%
INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C600 {600V}
INGETEAM POWER TECHNOLOGY SA
3,095,300 W -26010 W 600.0 V 1300.0 V 97.54%
Gamesa Electric: PV3800 {600V}
Gamesa Electric
3,418,394 W +297084 W 600.0 V 1300.0 V 97.53%
Sungrow Power Supply Co Ltd: SG3425UD {600V}
Sungrow Power Supply Co Ltd
3,434,560 W +313250 W 600.0 V 1300.0 V 97.26%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Power Electronics: FS3000K {600V}?

Check Power Electronics: FS3000K {600V} (3,121,310 W AC, 3,800 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on Power Electronics: FS3000K {600V}.

Power Electronics: FS3000K {600V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 3,800 A OCPD breaker (3003.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.89%) and MPPT window (849-1,200 V) directly against INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} (3,095,300 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Power Electronics: FS3000K {600V} by Power Electronics covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.

What breaker and wire size does Power Electronics: FS3000K {600V} require?

At 3,121,310 W continuous AC (600 V, 3-phase), continuous current is 3003.6 A; 125% NEC 690.8/705.12 sizing requires a 3,800 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Power Electronics: FS3000K {600V} require?

At 3,121,310 W AC and 600 V, 3-phase, continuous line current is 3003.6 A, requiring a 3,800 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.

How does Power Electronics: FS3000K {600V} compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V}?

Power Electronics: FS3000K {600V} delivers 3,121,310 W AC at 97.89% CEC efficiency with a 1,200 V DC ceiling, while INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C600 {600V} outputs 3,095,300 W at 600 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.