INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} outputs 2,582,000 W AC at 600 V, 3-phase (2484.6 A continuous, 3,150 A OCPD), ranking #488 of 2,343 CEC inverters at 97.65% efficiency with a 938-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 2,582,000 W
- AC Voltage
- 600 V, 3-phase
- Min PV Breaker
- 3,150 A (parallel Cu feeders)
- CEC Efficiency
- 97.65%
How Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} Compare Against Peer CEC Listings?
CEC efficiency rank (#488), 938-1,500 V MPPT tracking, and panel fit for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V}.
Operating at 600 V, 3-phase, INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} converts DC array energy at 97.65% CEC weighted efficiency (top 21.1%; higher than 78.9% of peers) with a 1,500 V max DC input and 2203.38 A max input current for NEC 690.7 string safety. Compare this 2,582,000 W grid-tied PV inverter directly with SMA America: SC 2750-EV-US {600V} (2,600,000 W). Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
Where Does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} at 2,582,000 W continuous AC output.
What Dataset Percentiles Define INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V}?
Dataset percentiles comparing INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} against 2,343 certified grid-support inverters nationwide.
What Do the Dataset Ranks Show for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V}?
Engineering highlights for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.
97.65% CEC Weighted Efficiency
-0.63 pts vs the 98.28% 600 V median; overall power rank #75 (2,582,000 W, top 3.2%; higher than 96.8% of peers).
3,150 A Required Backfeed OCPD
125% x 2484.6 A = 3105.8 A -> 3,150 A standard OCPD using parallel Cu feeders (75 C).
938 V - 1,500 V (Max 1,500 V DC)
Tracking span of 562.0 V; active in CEC directory (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 600 V, 3-phase switchgear (200A Bus / 200A Main (600V) to 1,200A Bus / 1,200A Main (600V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 2582000.0W / 600 V 3-phase -> 2484.6 A | Breaker >= 1.25 * 2484.6 = 3105.8 A -> 3,150 A
CEC Inverters.csv for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V}: Paco=2582000.0 W, Vac=600 V, Vdcmax=1500.0 V, Eff=97.65%.
Result: Min 3,150 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (600V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V}?
California Energy Commission Solar Equipment List parameters for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} (grid-tied PV inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 2,582,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 600 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,500 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 938 V - 1,500 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 2203.38 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.65% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} (600 V, 3-phase)?
Panelboard and switchgear backfeed allowances for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} (3,150 A OCPD).
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (600V) | 40 A | 3,150 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (600V) | 80 A | 3,150 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (600V) | 120 A | 3,150 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (600V) | 160 A | 3,150 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (600V) | 240 A | 3,150 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which CEC PV Module Strings Pair With INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V}.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 22 to 26 panels | 15.34 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 28 to 35 panels | 15.4 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 28 to 33 panels | 14.03 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 33 to 36 panels | 7.2 kW |
Which Competing Grid-Support Inverters Compare to INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V}?
Four alternative CEC inverters matched to INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} (2,582,000 W AC), led by SMA America: SC 2750-EV-US {600V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| SMA America: SC 2750-EV-US {600V} SMA America |
2,600,000 W | +18000 W | 600.0 V | 1200.0 V | 97.12% |
| SMA America: SC 2660 UP-US 600V 2566A {600V} SMA America |
2,616,157 W | +34157 W | 600.0 V | 1200.0 V | 96.52% |
| Power Electronics: FS2250CU15O3 {600V} Power Electronics |
2,420,370 W | -161630 W | 600.0 V | 1200.0 V | 97.82% |
| Power Electronics: FS2225CU15 {600V} Power Electronics |
2,417,080 W | -164920 W | 600.0 V | 1200.0 V | 97.76% |
What Are the Interconnection Limits and Best-Fit Uses for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V}?
Check INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} (2,582,000 W AC, 3,150 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 600 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (600V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V}.
INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 3,150 A OCPD breaker (2484.6 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.65%) and MPPT window (938-1,500 V) directly against SMA America: SC 2750-EV-US {600V} (2,600,000 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} by INGETEAM POWER TECHNOLOGY SA covering breaker sizing, MPPT limits, and 600 V, 3-phase interconnection.
What breaker and wire size does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} require?
At 2,582,000 W continuous AC (600 V, 3-phase), continuous current is 2484.6 A; 125% NEC 690.8/705.12 sizing requires a 3,150 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} require?
At 2,582,000 W AC and 600 V, 3-phase, continuous line current is 2484.6 A, requiring a 3,150 A OCPD and 1,200A Bus / 1,200A Main (600V) or NEC 705.11 interconnection.
How does INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} compare to SMA America: SC 2750-EV-US {600V}?
INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3930TL U HV C600 {600V} delivers 2,582,000 W AC at 97.65% CEC efficiency with a 1,500 V DC ceiling, while SMA America: SC 2750-EV-US {600V} outputs 2,600,000 W at 600 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)