SMA America: SC 4600 UP-US 690V 3850A {690V} outputs 4,198,235 W AC at 690 V, 3-phase (3512.9 A continuous, 4,400 A OCPD), ranking #205 of 2,343 CEC inverters at 98.27% efficiency with a 1,003-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 4,198,235 W
- AC Voltage
- 690 V, 3-phase
- Min PV Breaker
- 4,400 A (parallel Cu feeders)
- CEC Efficiency
- 98.27%
How Does SMA America: SC 4600 UP-US 690V 3850A {690V} Compare Against Peer CEC Listings?
CEC efficiency rank (#205), 1,003-1,200 V MPPT tracking, and panel fit for SMA America: SC 4600 UP-US 690V 3850A {690V}.
Operating at 690 V, 3-phase, SMA America: SC 4600 UP-US 690V 3850A {690V} converts DC array energy at 98.27% CEC weighted efficiency (top 8.9%; higher than 91.1% of peers) with a 1,200 V max DC input and 4022.63 A max input current for NEC 690.7 string safety. Compare this 4,198,235 W hybrid battery-capable inverter directly with Delta Electronics: PCS4300X-X00-US {690V} (4,308,400 W). Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap.
Where Does SMA America: SC 4600 UP-US 690V 3850A {690V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting SMA America: SC 4600 UP-US 690V 3850A {690V} at 4,198,235 W continuous AC output.
What Dataset Percentiles Define SMA America: SC 4600 UP-US 690V 3850A {690V}?
Dataset percentiles comparing SMA America: SC 4600 UP-US 690V 3850A {690V} against 2,343 certified grid-support inverters nationwide. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Do the Dataset Ranks Show for SMA America: SC 4600 UP-US 690V 3850A {690V}?
Engineering highlights for SMA America: SC 4600 UP-US 690V 3850A {690V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.
98.27% CEC Weighted Efficiency
+0.10 pts vs the 98.17% 690 V median; overall power rank #8 (4,198,235 W, top 0.3%; higher than 99.7% of peers).
4,400 A Required Backfeed OCPD
125% x 3512.9 A = 4391.1 A -> 4,400 A standard OCPD using parallel Cu feeders (75 C).
1,003 V - 1,200 V (Max 1,200 V DC)
Tracking span of 197.0 V; active in CEC directory (hybrid battery-capable inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 690 V, 3-phase switchgear (200A Bus / 200A Main (690V) to 1,200A Bus / 1,200A Main (690V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 4198235.0W / 690 V 3-phase -> 3512.9 A | Breaker >= 1.25 * 3512.9 = 4391.1 A -> 4,400 A
CEC Inverters.csv for SMA America: SC 4600 UP-US 690V 3850A {690V}: Paco=4198235.0 W, Vac=690 V, Vdcmax=1200.0 V, Eff=98.27%.
Result: Min 4,400 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (690V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for SMA America: SC 4600 UP-US 690V 3850A {690V}?
California Energy Commission Solar Equipment List parameters for SMA America: SC 4600 UP-US 690V 3850A {690V} (hybrid battery-capable inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 4,198,235 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 690 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,200 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 1,003 V - 1,200 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 4022.63 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.27% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to SMA America: SC 4600 UP-US 690V 3850A {690V} (690 V, 3-phase)?
Panelboard and switchgear backfeed allowances for SMA America: SC 4600 UP-US 690V 3850A {690V} (4,400 A OCPD). Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (690V) | 40 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (690V) | 80 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (690V) | 120 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (690V) | 160 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (690V) | 240 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which Competing Grid-Support Inverters Compare to SMA America: SC 4600 UP-US 690V 3850A {690V}?
Four alternative CEC inverters matched to SMA America: SC 4600 UP-US 690V 3850A {690V} (4,198,235 W AC), led by Delta Electronics: PCS4300X-X00-US {690V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: PCS4300X-X00-US {690V} Delta Electronics |
4,308,400 W | +110165 W | 690.0 V | 1500.0 V | 98.27% |
| Delta Electronics: PCS4300X-X01-US {690V} Delta Electronics |
4,009,000 W | -189235 W | 690.0 V | 1500.0 V | 98.35% |
| Gamesa Electric: PV4400 {690V} Gamesa Electric |
3,939,574 W | -258661 W | 690.0 V | 1300.0 V | 97.75% |
| Gamesa Electric: PV4700 {690V} Gamesa Electric |
4,654,418 W | +456183 W | 690.0 V | 1300.0 V | 97.8% |
What Are the Interconnection Limits and Best-Fit Uses for SMA America: SC 4600 UP-US 690V 3850A {690V}?
Check SMA America: SC 4600 UP-US 690V 3850A {690V} (4,198,235 W AC, 4,400 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 690 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (690V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SC 4600 UP-US 690V 3850A {690V}.
SMA America: SC 4600 UP-US 690V 3850A {690V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 4,400 A OCPD breaker (3512.9 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.27%) and MPPT window (1,003-1,200 V) directly against Delta Electronics: PCS4300X-X00-US {690V} (4,308,400 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for SMA America: SC 4600 UP-US 690V 3850A {690V} by SMA America covering breaker sizing, MPPT limits, and 690 V, 3-phase interconnection.
What breaker and wire size does SMA America: SC 4600 UP-US 690V 3850A {690V} require?
At 4,198,235 W continuous AC (690 V, 3-phase), continuous current is 3512.9 A; 125% NEC 690.8/705.12 sizing requires a 4,400 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does SMA America: SC 4600 UP-US 690V 3850A {690V} require?
At 4,198,235 W AC and 690 V, 3-phase, continuous line current is 3512.9 A, requiring a 4,400 A OCPD and 1,200A Bus / 1,200A Main (690V) or NEC 705.11 interconnection.
How does SMA America: SC 4600 UP-US 690V 3850A {690V} compare to Delta Electronics: PCS4300X-X00-US {690V}?
SMA America: SC 4600 UP-US 690V 3850A {690V} delivers 4,198,235 W AC at 98.27% CEC efficiency with a 1,200 V DC ceiling, while Delta Electronics: PCS4300X-X00-US {690V} outputs 4,308,400 W at 690 V, 3-phase.