SMA America: SC 4400 UP-US 660V 3850A {660V} outputs 4,017,113 W AC at 660 V, 3-phase (3514.2 A continuous, 4,400 A OCPD), ranking #238 of 2,343 CEC inverters at 98.21% efficiency with a 962-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 4,017,113 W
- AC Voltage
- 660 V, 3-phase
- Min PV Breaker
- 4,400 A (parallel Cu feeders)
- CEC Efficiency
- 98.21%
How Does SMA America: SC 4400 UP-US 660V 3850A {660V} Compare Against Peer CEC Listings?
CEC efficiency rank (#238), 962-1,200 V MPPT tracking, and panel fit for SMA America: SC 4400 UP-US 660V 3850A {660V}.
Operating at 660 V, 3-phase, SMA America: SC 4400 UP-US 660V 3850A {660V} converts DC array energy at 98.21% CEC weighted efficiency (top 10.5%; higher than 89.5% of peers) with a 1,200 V max DC input and 3963.52 A max input current for NEC 690.7 string safety. Compare this 4,017,113 W hybrid battery-capable inverter directly with Gamesa Electric: PV4200 {660V} (3,767,352 W). Commercial 660 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (660V) or NEC 705.11 supply-side tap.
Where Does SMA America: SC 4400 UP-US 660V 3850A {660V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting SMA America: SC 4400 UP-US 660V 3850A {660V} at 4,017,113 W continuous AC output.
What Dataset Percentiles Define SMA America: SC 4400 UP-US 660V 3850A {660V}?
Dataset percentiles comparing SMA America: SC 4400 UP-US 660V 3850A {660V} against 2,343 certified grid-support inverters nationwide. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for SMA America: SC 4400 UP-US 660V 3850A {660V}?
Engineering highlights for SMA America: SC 4400 UP-US 660V 3850A {660V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.
98.21% CEC Weighted Efficiency
equal to the 98.21% 660 V median; overall power rank #12 (4,017,113 W, top 0.5%; higher than 99.5% of peers).
4,400 A Required Backfeed OCPD
125% x 3514.2 A = 4392.8 A -> 4,400 A standard OCPD using parallel Cu feeders (75 C).
962 V - 1,200 V (Max 1,200 V DC)
Tracking span of 238.0 V; active in CEC directory (hybrid battery-capable inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 660 V, 3-phase switchgear (200A Bus / 200A Main (660V) to 1,200A Bus / 1,200A Main (660V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 4017113.0W / 660 V 3-phase -> 3514.2 A | Breaker >= 1.25 * 3514.2 = 4392.8 A -> 4,400 A
CEC Inverters.csv for SMA America: SC 4400 UP-US 660V 3850A {660V}: Paco=4017113.0 W, Vac=660 V, Vdcmax=1200.0 V, Eff=98.21%.
Result: Min 4,400 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (660V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for SMA America: SC 4400 UP-US 660V 3850A {660V}?
California Energy Commission Solar Equipment List parameters for SMA America: SC 4400 UP-US 660V 3850A {660V} (hybrid battery-capable inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 4,017,113 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 660 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,200 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 962 V - 1,200 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 3963.52 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.21% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to SMA America: SC 4400 UP-US 660V 3850A {660V} (660 V, 3-phase)?
Panelboard and switchgear backfeed allowances for SMA America: SC 4400 UP-US 660V 3850A {660V} (4,400 A OCPD). Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (660V) | 40 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (660V) | 80 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (660V) | 120 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (660V) | 160 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (660V) | 240 A | 4,400 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which Competing Grid-Support Inverters Compare to SMA America: SC 4400 UP-US 660V 3850A {660V}?
Four alternative CEC inverters matched to SMA America: SC 4400 UP-US 660V 3850A {660V} (4,017,113 W AC), led by Gamesa Electric: PV4200 {660V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Gamesa Electric: PV4200 {660V} Gamesa Electric |
3,767,352 W | -249761 W | 660.0 V | 1300.0 V | 97.78% |
| Gamesa Electric: PV4500 {660V} Gamesa Electric |
4,405,964 W | +388851 W | 660.0 V | 1300.0 V | 97.72% |
| INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C660 {660V} INGETEAM POWER TECHNOLOGY SA |
3,377,600 W | -639513 W | 660.0 V | 1300.0 V | 97.8% |
| INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C660 {660V} INGETEAM POWER TECHNOLOGY SA |
3,377,600 W | -639513 W | 660.0 V | 1300.0 V | 97.8% |
What Are the Interconnection Limits and Best-Fit Uses for SMA America: SC 4400 UP-US 660V 3850A {660V}?
Check SMA America: SC 4400 UP-US 660V 3850A {660V} (4,017,113 W AC, 4,400 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 660 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (660V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SC 4400 UP-US 660V 3850A {660V}.
SMA America: SC 4400 UP-US 660V 3850A {660V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 4,400 A OCPD breaker (3514.2 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.21%) and MPPT window (962-1,200 V) directly against Gamesa Electric: PV4200 {660V} (3,767,352 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for SMA America: SC 4400 UP-US 660V 3850A {660V} by SMA America covering breaker sizing, MPPT limits, and 660 V, 3-phase interconnection.
What breaker and wire size does SMA America: SC 4400 UP-US 660V 3850A {660V} require?
At 4,017,113 W continuous AC (660 V, 3-phase), continuous current is 3514.2 A; 125% NEC 690.8/705.12 sizing requires a 4,400 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does SMA America: SC 4400 UP-US 660V 3850A {660V} require?
At 4,017,113 W AC and 660 V, 3-phase, continuous line current is 3514.2 A, requiring a 4,400 A OCPD and 1,200A Bus / 1,200A Main (660V) or NEC 705.11 interconnection.
How does SMA America: SC 4400 UP-US 660V 3850A {660V} compare to Gamesa Electric: PV4200 {660V}?
SMA America: SC 4400 UP-US 660V 3850A {660V} delivers 4,017,113 W AC at 98.21% CEC efficiency with a 1,200 V DC ceiling, while Gamesa Electric: PV4200 {660V} outputs 3,767,352 W at 660 V, 3-phase.