Gamesa Electric: PV4500 {660V} — CEC Inverter Specifications

Manufacturer: Gamesa Electric Registry: CEC Verified Engineering Specification

Gamesa Electric: PV4500 {660V} outputs 4,405,964 W AC at 660 V, 3-phase (3854.3 A continuous, 4,850 A OCPD), ranking #459 of 2,343 CEC inverters at 97.72% efficiency with a 915-1,300 V MPPT window and 1,300 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
4,405,964 W
AC Voltage
660 V, 3-phase
Min PV Breaker
4,850 A (parallel Cu feeders)
CEC Efficiency
97.72%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gamesa Electric: PV4500 {660V} Compare Against Peer CEC Listings?

How Gamesa Electric Gamesa Electric: PV4500 {660V} compares on 97.72% efficiency, MPPT span, and 120% busbar interconnection. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Gamesa Electric certifies Gamesa Electric: PV4500 {660V} (grid-tied PV inverter, listed since 2021-12-01) at 4,405,964 W AC (1,564,084 W above the 2,841,880 W 660 V median). Its 1,300 V DC ceiling pairs with an MPPT window of 915-1,300 V (span 385.0 V). Under NEC 690.8/705.12, 125% sizing demands parallel Cu feeders conductors on a 4,850 A OCPD.

Where Does Gamesa Electric: PV4500 {660V} Fall Across Listed CEC Models?

Position of Gamesa Electric: PV4500 {660V} (4,405,964 W AC) relative to the 7,680 W CEC median inverter. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Gamesa Electric: PV4500 {660V} (4,405,964 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACGamesa Electric: P: 4,405,964 W

What Dataset Percentiles Define Gamesa Electric: PV4500 {660V}?

Percentile placement of Gamesa Electric: PV4500 {660V} across AC power class, conversion efficiency, and backfeed breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Gamesa Electric: PV4500 {660V} Technical ThresholdsPercentile comparison for Gamesa Electric: PV4500 {660V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output4,405,964 WCEC Efficiency97.72%Backfeed Breaker4,850 A

What Do the Dataset Ranks Show for Gamesa Electric: PV4500 {660V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Gamesa Electric: PV4500 {660V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Eff #459 / 2,343

97.72% CEC Weighted Efficiency

-0.49 pts vs the 98.21% 660 V median; overall power rank #3 (4,405,964 W, top 0.1%; higher than 99.9% of peers).

NEC 705.12 Check

4,850 A Required Backfeed OCPD

125% x 3854.3 A = 4817.9 A -> 4,850 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

915 V - 1,300 V (Max 1,300 V DC)

Tracking span of 385.0 V; listed since 2021-12-01 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 660 V, 3-phase switchgear (200A Bus / 200A Main (660V) to 1,200A Bus / 1,200A Main (660V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 4405964.0W / 660 V 3-phase -> 3854.3 A | Breaker >= 1.25 * 3854.3 = 4817.9 A -> 4,850 A

CEC Inverters.csv for Gamesa Electric: PV4500 {660V}: Paco=4405964.0 W, Vac=660 V, Vdcmax=1300.0 V, Eff=97.72%.

Result: Min 4,850 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (660V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for Gamesa Electric: PV4500 {660V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Gamesa Electric: PV4500 {660V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for Gamesa Electric: PV4500 {660V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 4,405,964 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 660 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,300 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 915 V - 1,300 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 4293.88 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.72% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2021-12-01 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Gamesa Electric: PV4500 {660V} (660 V, 3-phase)?

Check whether Gamesa Electric: PV4500 {660V} (4,850 A breaker) fits without main breaker derate or supply-side taps. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Evaluates Gamesa Electric: PV4500 {660V} (4850 A required OCPD at 660 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (660V) 40 A 4,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (660V) 80 A 4,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (660V) 120 A 4,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (660V) 160 A 4,850 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (660V) 240 A 4,850 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With Gamesa Electric: PV4500 {660V}?

Verified cold-weather (-10 C) series module counts matched to Gamesa Electric: PV4500 {660V}'s 1,300 V DC ceiling.

Sampled CEC PV modules aligned within 915.0-1300.0 V MPPT and 1300.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 22 to 23 panels 13.57 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 28 to 30 panels 13.2 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 27 to 29 panels 12.32 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 32 panels (fixed) 6.4 kW

Which Competing Grid-Support Inverters Compare to Gamesa Electric: PV4500 {660V}?

Alternative CEC inverters comparable to Gamesa Electric: PV4500 {660V}, including SMA America: SC 4400 UP-US 660V 3850A {660V} (4,017,113 W) at 660 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
SMA America: SC 4400 UP-US 660V 3850A {660V}
SMA America
4,017,113 W -388851 W 660.0 V 1200.0 V 98.21%
INGETEAM POWER TECHNOLOGY SA: INGECON SUN 3825TL U C660 {660V}
INGETEAM POWER TECHNOLOGY SA
3,377,600 W -1028364 W 660.0 V 1300.0 V 97.8%
INGETEAM POWER TECHNOLOGY SA: INGECON SUN STORAGE 3660TL U C660 {660V}
INGETEAM POWER TECHNOLOGY SA
3,377,600 W -1028364 W 660.0 V 1300.0 V 97.8%
POWER ELECTRONICS: FP3151K {660V}
POWER ELECTRONICS
3,145,170 W -1260794 W 660.0 V 1200.0 V 98.6%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Gamesa Electric: PV4500 {660V}?

Check Gamesa Electric: PV4500 {660V} (4,405,964 W AC, 4,850 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 660 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (660V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,300 V DC on Gamesa Electric: PV4500 {660V}.

Gamesa Electric: PV4500 {660V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 4,850 A OCPD breaker (3854.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.72%) and MPPT window (915-1,300 V) directly against SMA America: SC 4400 UP-US 660V 3850A {660V} (4,017,113 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Gamesa Electric: PV4500 {660V} by Gamesa Electric covering breaker sizing, MPPT limits, and 660 V, 3-phase interconnection.

What breaker and wire size does Gamesa Electric: PV4500 {660V} require?

At 4,405,964 W continuous AC (660 V, 3-phase), continuous current is 3854.3 A; 125% NEC 690.8/705.12 sizing requires a 4,850 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does Gamesa Electric: PV4500 {660V} require?

At 4,405,964 W AC and 660 V, 3-phase, continuous line current is 3854.3 A, requiring a 4,850 A OCPD and 1,200A Bus / 1,200A Main (660V) or NEC 705.11 interconnection.

How does Gamesa Electric: PV4500 {660V} compare to SMA America: SC 4400 UP-US 660V 3850A {660V}?

Gamesa Electric: PV4500 {660V} delivers 4,405,964 W AC at 97.72% CEC efficiency with a 1,300 V DC ceiling, while SMA America: SC 4400 UP-US 660V 3850A {660V} outputs 4,017,113 W at 660 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.