SMA America: SC 4200 UP-US 630V 3850A {630V} — CEC Inverter Specifications

Manufacturer: SMA America Registry: CEC Verified Engineering Specification

SMA America: SC 4200 UP-US 630V 3850A {630V} outputs 3,832,828 W AC at 630 V, 3-phase (3512.6 A continuous, 4,400 A OCPD), ranking #282 of 2,343 CEC inverters at 98.13% efficiency with a 921-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
3,832,828 W
AC Voltage
630 V, 3-phase
Min PV Breaker
4,400 A (parallel Cu feeders)
CEC Efficiency
98.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SMA America: SC 4200 UP-US 630V 3850A {630V} Compare Against Peer CEC Listings?

CEC efficiency rank (#282), 921-1,200 V MPPT tracking, and panel fit for SMA America: SC 4200 UP-US 630V 3850A {630V}.

Operating at 630 V, 3-phase, SMA America: SC 4200 UP-US 630V 3850A {630V} converts DC array energy at 98.13% CEC weighted efficiency (top 12.2%; higher than 87.8% of peers) with a 1,200 V max DC input and 3901.8 A max input current for NEC 690.7 string safety. Compare this 3,832,828 W hybrid battery-capable inverter directly with Power Electronics: FS4010K {630V} (4,058,537 W). Commercial 630 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (630V) or NEC 705.11 supply-side tap.

Where Does SMA America: SC 4200 UP-US 630V 3850A {630V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting SMA America: SC 4200 UP-US 630V 3850A {630V} at 3,832,828 W continuous AC output.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where SMA America: SC 4200 UP-US 630V 3850A {630V} (3,832,828 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSMA America: SC 42: 3,832,828 W

What Dataset Percentiles Define SMA America: SC 4200 UP-US 630V 3850A {630V}?

Dataset percentiles comparing SMA America: SC 4200 UP-US 630V 3850A {630V} against 2,343 certified grid-support inverters nationwide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

SMA America: SC 4200 UP-US 630V 3850A {630V} Technical ThresholdsPercentile comparison for SMA America: SC 4200 UP-US 630V 3850A {630V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output3,832,828 WCEC Efficiency98.13%Backfeed Breaker4,400 A

What Do the Dataset Ranks Show for SMA America: SC 4200 UP-US 630V 3850A {630V}?

Engineering highlights for SMA America: SC 4200 UP-US 630V 3850A {630V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.

Eff #282 / 2,343

98.13% CEC Weighted Efficiency

+0.19 pts vs the 97.94% 630 V median; overall power rank #15 (3,832,828 W, top 0.6%; higher than 99.4% of peers).

NEC 705.12 Check

4,400 A Required Backfeed OCPD

125% x 3512.6 A = 4390.8 A -> 4,400 A standard OCPD using parallel Cu feeders (75 C).

MPPT Window

921 V - 1,200 V (Max 1,200 V DC)

Tracking span of 279.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 630 V, 3-phase switchgear (200A Bus / 200A Main (630V) to 1,200A Bus / 1,200A Main (630V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 3832828.0W / 630 V 3-phase -> 3512.6 A | Breaker >= 1.25 * 3512.6 = 4390.8 A -> 4,400 A

CEC Inverters.csv for SMA America: SC 4200 UP-US 630V 3850A {630V}: Paco=3832828.0 W, Vac=630 V, Vdcmax=1200.0 V, Eff=98.13%.

Result: Min 4,400 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (630V): Supply-Side Tap (705.11) / Dedicated Switchboard.

What Are the Published CEC Specifications for SMA America: SC 4200 UP-US 630V 3850A {630V}?

California Energy Commission Solar Equipment List parameters for SMA America: SC 4200 UP-US 630V 3850A {630V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for SMA America: SC 4200 UP-US 630V 3850A {630V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 3,832,828 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 630 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 921 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 3901.8 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.13% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to SMA America: SC 4200 UP-US 630V 3850A {630V} (630 V, 3-phase)?

Panelboard and switchgear backfeed allowances for SMA America: SC 4200 UP-US 630V 3850A {630V} (4,400 A OCPD). Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Evaluates SMA America: SC 4200 UP-US 630V 3850A {630V} (4400 A required OCPD at 630 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (630V) 40 A 4,400 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (630V) 80 A 4,400 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (630V) 120 A 4,400 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (630V) 160 A 4,400 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (630V) 240 A 4,400 A Supply-Side Tap (705.11) / Dedicated Switchboard

Which CEC PV Module Strings Pair With SMA America: SC 4200 UP-US 630V 3850A {630V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for SMA America: SC 4200 UP-US 630V 3850A {630V}.

Sampled CEC PV modules aligned within 921.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 28 panels (fixed) 12.32 kW

Which Competing Grid-Support Inverters Compare to SMA America: SC 4200 UP-US 630V 3850A {630V}?

Four alternative CEC inverters matched to SMA America: SC 4200 UP-US 630V 3850A {630V} (3,832,828 W AC), led by Power Electronics: FS4010K {630V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Power Electronics: FS4010K {630V}
Power Electronics
4,058,537 W +225709 W 630.0 V 1200.0 V 97.83%
Sungrow Power Supply Co Ltd: SG3600UD {630V}
Sungrow Power Supply Co Ltd
3,606,980 W -225848 W 630.0 V 1300.0 V 97.27%
Gamesa Electric: PV4000 {630V}
Gamesa Electric
3,597,332 W -235496 W 630.0 V 1300.0 V 97.62%
Gamesa Electric: PV4300 {630V}
Gamesa Electric
4,260,428 W +427600 W 630.0 V 1300.0 V 97.6%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for SMA America: SC 4200 UP-US 630V 3850A {630V}?

Check SMA America: SC 4200 UP-US 630V 3850A {630V} (3,832,828 W AC, 4,400 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 630 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (630V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on SMA America: SC 4200 UP-US 630V 3850A {630V}.

SMA America: SC 4200 UP-US 630V 3850A {630V} Panel & Wire Spec

Size 75 C copper conductors at parallel Cu feeders on a 4,400 A OCPD breaker (3512.6 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.13%) and MPPT window (921-1,200 V) directly against Power Electronics: FS4010K {630V} (4,058,537 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for SMA America: SC 4200 UP-US 630V 3850A {630V} by SMA America covering breaker sizing, MPPT limits, and 630 V, 3-phase interconnection.

What breaker and wire size does SMA America: SC 4200 UP-US 630V 3850A {630V} require?

At 3,832,828 W continuous AC (630 V, 3-phase), continuous current is 3512.6 A; 125% NEC 690.8/705.12 sizing requires a 4,400 A breaker and parallel Cu feeders (75 C) wire.

What commercial switchgear or feeder sizing does SMA America: SC 4200 UP-US 630V 3850A {630V} require?

At 3,832,828 W AC and 630 V, 3-phase, continuous line current is 3512.6 A, requiring a 4,400 A OCPD and 1,200A Bus / 1,200A Main (630V) or NEC 705.11 interconnection.

How does SMA America: SC 4200 UP-US 630V 3850A {630V} compare to Power Electronics: FS4010K {630V}?

SMA America: SC 4200 UP-US 630V 3850A {630V} delivers 3,832,828 W AC at 98.13% CEC efficiency with a 1,200 V DC ceiling, while Power Electronics: FS4010K {630V} outputs 4,058,537 W at 630 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.