SMA America: SBSE58-US-50 {240V} outputs 5,776 W AC at 240 V (24.1 A continuous, 35 A OCPD), ranking #595 of 2,343 CEC inverters at 97.41% efficiency with a 136-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 5,776 W
- AC Voltage
- 240 V
- Min PV Breaker
- 35 A (8 AWG Cu)
- CEC Efficiency
- 97.41%
How Does SMA America: SBSE58-US-50 {240V} Compare Against Peer CEC Listings?
CEC efficiency rank (#595), 136-480 V MPPT tracking, and panel fit for SMA America: SBSE58-US-50 {240V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
SMA America: SBSE58-US-50 {240V} from SMA America outputs 24.1 A continuous AC at 240 V (5,776 W AC, rank #1,435). Paired with 8 AWG Cu conductors and a 35 A OCPD, its 97.41% CEC efficiency compares closely with Delta Electronics: E6-TL-US {240V} (5,760 W). Keep NEC 690.7 winter string Voc below 480 V DC.
Where Does SMA America: SBSE58-US-50 {240V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting SMA America: SBSE58-US-50 {240V} at 5,776 W continuous AC output. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Dataset Percentiles Define SMA America: SBSE58-US-50 {240V}?
Dataset percentiles comparing SMA America: SBSE58-US-50 {240V} against 2,343 certified grid-support inverters nationwide. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for SMA America: SBSE58-US-50 {240V}?
Engineering highlights for SMA America: SBSE58-US-50 {240V} covering efficiency, 8 AWG Cu feeder, and panel compatibility. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
97.41% CEC Weighted Efficiency
+0.73 pts vs the 96.68% 240 V median; overall power rank #1,435 (5,776 W, below CEC median; higher than 38.8% of peers).
35 A Required Backfeed OCPD
125% x 24.1 A = 30.1 A -> 35 A standard OCPD using 8 AWG Cu (75 C).
136 V - 480 V (Max 480 V DC)
Tracking span of 344.0 V; active in CEC directory (hybrid battery-capable inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 5775.9W / 240 V -> 24.1 A | Breaker >= 1.25 * 24.1 = 30.1 A -> 35 A
CEC Inverters.csv for SMA America: SBSE58-US-50 {240V}: Paco=5775.9 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.41%.
Result: Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for SMA America: SBSE58-US-50 {240V}?
California Energy Commission Solar Equipment List parameters for SMA America: SBSE58-US-50 {240V} (hybrid battery-capable inverter) interconnection. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 5,776 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 136 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 15.2429 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 97.41% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for SMA America: SBSE58-US-50 {240V}?
Panelboard and switchgear backfeed allowances for SMA America: SBSE58-US-50 {240V} (35 A OCPD). All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 35 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 35 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 35 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 35 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 35 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With SMA America: SBSE58-US-50 {240V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for SMA America: SBSE58-US-50 {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 4 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 5 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 4 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 5 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to SMA America: SBSE58-US-50 {240V}?
Four alternative CEC inverters matched to SMA America: SBSE58-US-50 {240V} (5,776 W AC), led by Delta Electronics: E6-TL-US {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: E6-TL-US {240V} Delta Electronics |
5,760 W | -16 W | 240.0 V | 480.0 V | 97.35% |
| Delta Electronics: M6-TL-US {240V} Delta Electronics |
5,760 W | -16 W | 240.0 V | 480.0 V | 97.37% |
| Delta Electronics: E6_BDI {240V} Delta Electronics |
5,823 W | +47 W | 240.0 V | 480.0 V | 97.63% |
| Base Power Inc: MIN 6000TL-XH-US {240V} Base Power Inc |
5,918 W | +142 W | 240.0 V | 480.0 V | 97.26% |
What Are the Interconnection Limits and Best-Fit Uses for SMA America: SBSE58-US-50 {240V}?
Check SMA America: SBSE58-US-50 {240V} (5,776 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on SMA America: SBSE58-US-50 {240V}.
SMA America: SBSE58-US-50 {240V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (24.1 A continuous).
Alternative Inverter Comparison
Compare efficiency (97.41%) and MPPT window (136-480 V) directly against Delta Electronics: E6-TL-US {240V} (5,760 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for SMA America: SBSE58-US-50 {240V} by SMA America covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does SMA America: SBSE58-US-50 {240V} require?
At 5,776 W continuous AC (240 V), continuous current is 24.1 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.
Does SMA America: SBSE58-US-50 {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 240 V means PASS (120% Rule).
How does SMA America: SBSE58-US-50 {240V} compare to Delta Electronics: E6-TL-US {240V}?
SMA America: SBSE58-US-50 {240V} delivers 5,776 W AC at 97.41% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: E6-TL-US {240V} outputs 5,760 W at 240 V.