Base Power Inc: MIN 6000TL-XH-US {240V} — CEC Inverter Specifications

Manufacturer: Base Power Inc Registry: CEC Verified Engineering Specification

Base Power Inc: MIN 6000TL-XH-US {240V} outputs 5,918 W AC at 240 V (24.7 A continuous, 35 A OCPD), ranking #711 of 2,343 CEC inverters at 97.26% efficiency with a 170-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
5,918 W
AC Voltage
240 V
Min PV Breaker
35 A (8 AWG Cu)
CEC Efficiency
97.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Base Power Inc: MIN 6000TL-XH-US {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#711), 170-480 V MPPT tracking, and panel fit for Base Power Inc: MIN 6000TL-XH-US {240V}.

Operating at 240 V, Base Power Inc: MIN 6000TL-XH-US {240V} converts DC array energy at 97.26% CEC weighted efficiency (top 30.7%; higher than 69.3% of peers) with a 480 V max DC input and 16.0121 A max input current for NEC 690.7 string safety. Compare this 5,918 W hybrid battery-capable inverter directly with Afore New Energy Technology (Shanghai) Co Ltd: AF6K-DH {240V} (5,995 W). Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).

Where Does Base Power Inc: MIN 6000TL-XH-US {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Base Power Inc: MIN 6000TL-XH-US {240V} at 5,918 W continuous AC output. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Base Power Inc: MIN 6000TL-XH-US {240V} (5,918 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACBase Power Inc: MI: 5,918 W

What Dataset Percentiles Define Base Power Inc: MIN 6000TL-XH-US {240V}?

Dataset percentiles comparing Base Power Inc: MIN 6000TL-XH-US {240V} against 2,343 certified grid-support inverters nationwide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Base Power Inc: MIN 6000TL-XH-US {240V} Technical ThresholdsPercentile comparison for Base Power Inc: MIN 6000TL-XH-US {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output5,918 WCEC Efficiency97.26%Backfeed Breaker35 A

What Do the Dataset Ranks Show for Base Power Inc: MIN 6000TL-XH-US {240V}?

Engineering highlights for Base Power Inc: MIN 6000TL-XH-US {240V} covering efficiency, 8 AWG Cu feeder, and panel compatibility.

Eff #711 / 2,343

97.26% CEC Weighted Efficiency

+0.58 pts vs the 96.68% 240 V median; overall power rank #1,427 (5,918 W, below CEC median; higher than 39.0% of peers).

NEC 705.12 Check

35 A Required Backfeed OCPD

125% x 24.7 A = 30.9 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

170 V - 480 V (Max 480 V DC)

Tracking span of 310.0 V; active in CEC directory (hybrid battery-capable inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 5918.0W / 240 V -> 24.7 A | Breaker >= 1.25 * 24.7 = 30.9 A -> 35 A

CEC Inverters.csv for Base Power Inc: MIN 6000TL-XH-US {240V}: Paco=5918.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.26%.

Result: Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Base Power Inc: MIN 6000TL-XH-US {240V}?

California Energy Commission Solar Equipment List parameters for Base Power Inc: MIN 6000TL-XH-US {240V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Base Power Inc: MIN 6000TL-XH-US {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 5,918 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 170 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 16.0121 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.26% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Base Power Inc: MIN 6000TL-XH-US {240V}?

Panelboard and switchgear backfeed allowances for Base Power Inc: MIN 6000TL-XH-US {240V} (35 A OCPD). Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Evaluates Base Power Inc: MIN 6000TL-XH-US {240V} (35 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 35 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 35 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 35 A PASS (120% Rule)
200A Bus / 175A Main 65 A 35 A PASS (120% Rule)
225A Bus / 200A Main 70 A 35 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Base Power Inc: MIN 6000TL-XH-US {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Base Power Inc: MIN 6000TL-XH-US {240V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sampled CEC PV modules aligned within 170.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 4 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 5 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 6 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Base Power Inc: MIN 6000TL-XH-US {240V}?

Four alternative CEC inverters matched to Base Power Inc: MIN 6000TL-XH-US {240V} (5,918 W AC), led by Afore New Energy Technology (Shanghai) Co Ltd: AF6K-DH {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Afore New Energy Technology (Shanghai) Co Ltd: AF6K-DH {240V}
Afore New Energy Technology (Shanghai) Co Ltd
5,995 W +77 W 240.0 V 480.0 V 97.6%
ABB: PVI-6000-OUTD-US-A {240V}
ABB
6,000 W +82 W 240.0 V 480.0 V 96.21%
ABB: PVI-6000-OUTD-US-Z-A {240V}
ABB
6,000 W +82 W 240.0 V 480.0 V 96.21%
ABB: PVI-6000-OUTD-US-Z-M-A {240V}
ABB
6,000 W +82 W 240.0 V 480.0 V 96.21%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Base Power Inc: MIN 6000TL-XH-US {240V}?

Check Base Power Inc: MIN 6000TL-XH-US {240V} (5,918 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Base Power Inc: MIN 6000TL-XH-US {240V}.

Base Power Inc: MIN 6000TL-XH-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (24.7 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.26%) and MPPT window (170-480 V) directly against Afore New Energy Technology (Shanghai) Co Ltd: AF6K-DH {240V} (5,995 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Base Power Inc: MIN 6000TL-XH-US {240V} by Base Power Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Base Power Inc: MIN 6000TL-XH-US {240V} require?

At 5,918 W continuous AC (240 V), continuous current is 24.7 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

Does Base Power Inc: MIN 6000TL-XH-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 240 V means PASS (120% Rule).

How does Base Power Inc: MIN 6000TL-XH-US {240V} compare to Afore New Energy Technology (Shanghai) Co Ltd: AF6K-DH {240V}?

Base Power Inc: MIN 6000TL-XH-US {240V} delivers 5,918 W AC at 97.26% CEC efficiency with a 480 V DC ceiling, while Afore New Energy Technology (Shanghai) Co Ltd: AF6K-DH {240V} outputs 5,995 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.