Delta Electronics: E6-TL-US {240V} — CEC Inverter Specifications

Manufacturer: Delta Electronics Registry: CEC Verified Engineering Specification

Delta Electronics: E6-TL-US {240V} outputs 5,760 W AC at 240 V (24.0 A continuous, 30 A OCPD), ranking #654 of 2,343 CEC inverters at 97.35% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
5,760 W
AC Voltage
240 V
Min PV Breaker
30 A (10 AWG Cu)
CEC Efficiency
97.35%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Delta Electronics: E6-TL-US {240V} Compare Against Peer CEC Listings?

How Delta Electronics Delta Electronics: E6-TL-US {240V} compares on 97.35% efficiency, MPPT span, and 120% busbar interconnection. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

With a 200-480 V MPPT tracking band and 480 V DC ceiling, Delta Electronics: E6-TL-US {240V} handles 5,760 W continuous AC (16 W below the 5,776 W 240 V median). Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Installers comparing Delta Electronics against Base Power Inc: MIN 6000TL-XH-US {240V} (5,918 W) should verify whether listed since 2024-04-02 grid-support firmware meets local IEEE 1547 utility rules.

Where Does Delta Electronics: E6-TL-US {240V} Fall Across Listed CEC Models?

Position of Delta Electronics: E6-TL-US {240V} (5,760 W AC) relative to the 7,680 W CEC median inverter. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Delta Electronics: E6-TL-US {240V} (5,760 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACDelta Electronics:: 5,760 W

What Dataset Percentiles Define Delta Electronics: E6-TL-US {240V}?

Percentile placement of Delta Electronics: E6-TL-US {240V} across AC power class, conversion efficiency, and backfeed breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Delta Electronics: E6-TL-US {240V} Technical ThresholdsPercentile comparison for Delta Electronics: E6-TL-US {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output5,760 WCEC Efficiency97.35%Backfeed Breaker30 A

What Do the Dataset Ranks Show for Delta Electronics: E6-TL-US {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Delta Electronics: E6-TL-US {240V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Eff #654 / 2,343

97.35% CEC Weighted Efficiency

+0.67 pts vs the 96.68% 240 V median; overall power rank #1,436 (5,760 W, below CEC median; higher than 38.6% of peers).

NEC 705.12 Check

30 A Required Backfeed OCPD

125% x 24.0 A = 30.0 A -> 30 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; listed since 2024-04-02 (hybrid battery-capable inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 5760.0W / 240 V -> 24.0 A | Breaker >= 1.25 * 24.0 = 30.0 A -> 30 A

CEC Inverters.csv for Delta Electronics: E6-TL-US {240V}: Paco=5760.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=97.35%.

Result: Min 30 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Delta Electronics: E6-TL-US {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Delta Electronics: E6-TL-US {240V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for Delta Electronics: E6-TL-US {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 5,760 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 15.5702 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.35% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2024-04-02 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for Delta Electronics: E6-TL-US {240V}?

Check whether Delta Electronics: E6-TL-US {240V} (30 A breaker) fits without main breaker derate or supply-side taps. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Evaluates Delta Electronics: E6-TL-US {240V} (30 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 30 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 30 A PASS (120% Rule)
200A Bus / 200A Main 40 A 30 A PASS (120% Rule)
200A Bus / 175A Main 65 A 30 A PASS (120% Rule)
225A Bus / 200A Main 70 A 30 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Delta Electronics: E6-TL-US {240V}?

Verified cold-weather (-10 C) series module counts matched to Delta Electronics: E6-TL-US {240V}'s 480 V DC ceiling.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Delta Electronics: E6-TL-US {240V}?

Alternative CEC inverters comparable to Delta Electronics: E6-TL-US {240V}, including Base Power Inc: MIN 6000TL-XH-US {240V} (5,918 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Base Power Inc: MIN 6000TL-XH-US {240V}
Base Power Inc
5,918 W +158 W 240.0 V 480.0 V 97.26%
Afore New Energy Technology (Shanghai) Co Ltd: AF6K-DH {240V}
Afore New Energy Technology (Shanghai) Co Ltd
5,995 W +235 W 240.0 V 480.0 V 97.6%
ABB: PVI-6000-OUTD-US-A {240V}
ABB
6,000 W +240 W 240.0 V 480.0 V 96.21%
ABB: PVI-6000-OUTD-US-Z-A {240V}
ABB
6,000 W +240 W 240.0 V 480.0 V 96.21%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Delta Electronics: E6-TL-US {240V}?

Check Delta Electronics: E6-TL-US {240V} (5,760 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Delta Electronics: E6-TL-US {240V}.

Delta Electronics: E6-TL-US {240V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (24.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.35%) and MPPT window (200-480 V) directly against Base Power Inc: MIN 6000TL-XH-US {240V} (5,918 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Delta Electronics: E6-TL-US {240V} by Delta Electronics covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Delta Electronics: E6-TL-US {240V} require?

At 5,760 W continuous AC (240 V), continuous current is 24.0 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.

Does Delta Electronics: E6-TL-US {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 30 A at 240 V means PASS (120% Rule).

How does Delta Electronics: E6-TL-US {240V} compare to Base Power Inc: MIN 6000TL-XH-US {240V}?

Delta Electronics: E6-TL-US {240V} delivers 5,760 W AC at 97.35% CEC efficiency with a 480 V DC ceiling, while Base Power Inc: MIN 6000TL-XH-US {240V} outputs 5,918 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.