OutBack Power: VFXR3524A {120V} outputs 2,960 W AC at 120 V (24.7 A continuous, 35 A OCPD), ranking #2,342 of 2,343 CEC inverters at 88.54% efficiency with a 22-28 V MPPT window and 28 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 2,960 W
- AC Voltage
- 120 V
- Min PV Breaker
- 35 A (8 AWG Cu)
- CEC Efficiency
- 88.54%
How Does OutBack Power: VFXR3524A {120V} Compare Against Peer CEC Listings?
CEC efficiency rank (#2,342), 22-28 V MPPT tracking, and panel fit for OutBack Power: VFXR3524A {120V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Operating at 120 V, OutBack Power: VFXR3524A {120V} converts DC array energy at 88.54% CEC weighted efficiency (below overall CEC median; higher than 0.0% of peers) with a 28 V max DC input and 139.292 A max input current for NEC 690.7 string safety. Compare this 2,960 W grid-tied PV inverter directly with Northern Electric & Power Co Ltd: BDM-1600-LV {120V} (1,597 W). Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
Where Does OutBack Power: VFXR3524A {120V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting OutBack Power: VFXR3524A {120V} at 2,960 W continuous AC output. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Dataset Percentiles Define OutBack Power: VFXR3524A {120V}?
Dataset percentiles comparing OutBack Power: VFXR3524A {120V} against 2,343 certified grid-support inverters nationwide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for OutBack Power: VFXR3524A {120V}?
Engineering highlights for OutBack Power: VFXR3524A {120V} covering efficiency, 8 AWG Cu feeder, and panel compatibility. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
88.54% CEC Weighted Efficiency
-6.19 pts vs the 94.73% 120 V median; overall power rank #1,754 (2,960 W, below CEC median; higher than 25.1% of peers).
35 A Required Backfeed OCPD
125% x 24.7 A = 30.9 A -> 35 A standard OCPD using 8 AWG Cu (75 C).
22 V - 28 V (Max 28 V DC)
Tracking span of 6.0 V; listed since 2018-10-15 (grid-tied PV inverter).
120V AC Coupled / Dedicated Transformer
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 2960.0W / 120 V -> 24.7 A | Breaker >= 1.25 * 24.7 = 30.9 A -> 35 A
CEC Inverters.csv for OutBack Power: VFXR3524A {120V}: Paco=2960.0 W, Vac=120 V, Vdcmax=28.0 V, Eff=88.54%.
Result: Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: 120V AC Coupled / Dedicated Transformer.
What Are the Published CEC Specifications for OutBack Power: VFXR3524A {120V}?
California Energy Commission Solar Equipment List parameters for OutBack Power: VFXR3524A {120V} (grid-tied PV inverter) interconnection. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 2,960 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 120 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 28 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 22 V - 28 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 139.292 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 88.54% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2018-10-15 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for OutBack Power: VFXR3524A {120V}?
Panelboard and switchgear backfeed allowances for OutBack Power: VFXR3524A {120V} (35 A OCPD). Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 35 A | 120V AC Coupled / Dedicated Transformer |
| 150A Bus / 150A Main | 30 A | 35 A | 120V AC Coupled / Dedicated Transformer |
| 200A Bus / 200A Main | 40 A | 35 A | 120V AC Coupled / Dedicated Transformer |
| 200A Bus / 175A Main | 65 A | 35 A | 120V AC Coupled / Dedicated Transformer |
| 225A Bus / 200A Main | 70 A | 35 A | 120V AC Coupled / Dedicated Transformer |
Which Competing Grid-Support Inverters Compare to OutBack Power: VFXR3524A {120V}?
Four alternative CEC inverters matched to OutBack Power: VFXR3524A {120V} (2,960 W AC), led by Northern Electric & Power Co Ltd: BDM-1600-LV {120V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Northern Electric & Power Co Ltd: BDM-1600-LV {120V} Northern Electric & Power Co Ltd |
1,597 W | -1363 W | 120.0 V | 55.0 V | 96.31% |
| Northern Electric & Power Co Ltd: BDM-1200-LV {120V} Northern Electric & Power Co Ltd |
1,194 W | -1766 W | 120.0 V | 55.0 V | 96.23% |
| Power Center: Essential Hybrid 5 {120V} Power Center |
4,787 W | +1827 W | 120.0 V | 425.0 V | 95.59% |
| Sol-Ark: 5K-120V/8K-230V-1P {120V} Sol-Ark |
4,787 W | +1827 W | 120.0 V | 425.0 V | 95.59% |
What Are the Interconnection Limits and Best-Fit Uses for OutBack Power: VFXR3524A {120V}?
Check OutBack Power: VFXR3524A {120V} (2,960 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 28 V DC on OutBack Power: VFXR3524A {120V}.
OutBack Power: VFXR3524A {120V} Panel & Wire Spec
Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (24.7 A continuous).
Alternative Inverter Comparison
Compare efficiency (88.54%) and MPPT window (22-28 V) directly against Northern Electric & Power Co Ltd: BDM-1600-LV {120V} (1,597 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for OutBack Power: VFXR3524A {120V} by OutBack Power covering breaker sizing, MPPT limits, and 120 V interconnection.
What breaker and wire size does OutBack Power: VFXR3524A {120V} require?
At 2,960 W continuous AC (120 V), continuous current is 24.7 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.
Does OutBack Power: VFXR3524A {120V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 120 V means 120V AC Coupled / Dedicated Transformer.
How does OutBack Power: VFXR3524A {120V} compare to Northern Electric & Power Co Ltd: BDM-1600-LV {120V}?
OutBack Power: VFXR3524A {120V} delivers 2,960 W AC at 88.54% CEC efficiency with a 28 V DC ceiling, while Northern Electric & Power Co Ltd: BDM-1600-LV {120V} outputs 1,597 W at 120 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)