Manufacturer: OutBack Power Registry: CEC Verified Engineering Specification

OutBack Power: VFXR3524A {120V} outputs 2,960 W AC at 120 V (24.7 A continuous, 35 A OCPD), ranking #2,342 of 2,343 CEC inverters at 88.54% efficiency with a 22-28 V MPPT window and 28 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
2,960 W
AC Voltage
120 V
Min PV Breaker
35 A (8 AWG Cu)
CEC Efficiency
88.54%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does OutBack Power: VFXR3524A {120V} Compare Against Peer CEC Listings?

CEC efficiency rank (#2,342), 22-28 V MPPT tracking, and panel fit for OutBack Power: VFXR3524A {120V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Operating at 120 V, OutBack Power: VFXR3524A {120V} converts DC array energy at 88.54% CEC weighted efficiency (below overall CEC median; higher than 0.0% of peers) with a 28 V max DC input and 139.292 A max input current for NEC 690.7 string safety. Compare this 2,960 W grid-tied PV inverter directly with Northern Electric & Power Co Ltd: BDM-1600-LV {120V} (1,597 W). Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).

Where Does OutBack Power: VFXR3524A {120V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting OutBack Power: VFXR3524A {120V} at 2,960 W continuous AC output. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where OutBack Power: VFXR3524A {120V} (2,960 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACOutBack Power: VFX: 2,960 W

What Dataset Percentiles Define OutBack Power: VFXR3524A {120V}?

Dataset percentiles comparing OutBack Power: VFXR3524A {120V} against 2,343 certified grid-support inverters nationwide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

OutBack Power: VFXR3524A {120V} Technical ThresholdsPercentile comparison for OutBack Power: VFXR3524A {120V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output2,960 WCEC Efficiency88.54%Backfeed Breaker35 A

What Do the Dataset Ranks Show for OutBack Power: VFXR3524A {120V}?

Engineering highlights for OutBack Power: VFXR3524A {120V} covering efficiency, 8 AWG Cu feeder, and panel compatibility. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Eff #2,342 / 2,343

88.54% CEC Weighted Efficiency

-6.19 pts vs the 94.73% 120 V median; overall power rank #1,754 (2,960 W, below CEC median; higher than 25.1% of peers).

NEC 705.12 Check

35 A Required Backfeed OCPD

125% x 24.7 A = 30.9 A -> 35 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

22 V - 28 V (Max 28 V DC)

Tracking span of 6.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Panel Fit (240V)

120V AC Coupled / Dedicated Transformer

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 2960.0W / 120 V -> 24.7 A | Breaker >= 1.25 * 24.7 = 30.9 A -> 35 A

CEC Inverters.csv for OutBack Power: VFXR3524A {120V}: Paco=2960.0 W, Vac=120 V, Vdcmax=28.0 V, Eff=88.54%.

Result: Min 35 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: 120V AC Coupled / Dedicated Transformer.

What Are the Published CEC Specifications for OutBack Power: VFXR3524A {120V}?

California Energy Commission Solar Equipment List parameters for OutBack Power: VFXR3524A {120V} (grid-tied PV inverter) interconnection. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for OutBack Power: VFXR3524A {120V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 2,960 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 120 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 28 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 22 V - 28 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 139.292 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 88.54% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for OutBack Power: VFXR3524A {120V}?

Panelboard and switchgear backfeed allowances for OutBack Power: VFXR3524A {120V} (35 A OCPD). Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Evaluates OutBack Power: VFXR3524A {120V} (35 A required OCPD at 120 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 35 A 120V AC Coupled / Dedicated Transformer
150A Bus / 150A Main 30 A 35 A 120V AC Coupled / Dedicated Transformer
200A Bus / 200A Main 40 A 35 A 120V AC Coupled / Dedicated Transformer
200A Bus / 175A Main 65 A 35 A 120V AC Coupled / Dedicated Transformer
225A Bus / 200A Main 70 A 35 A 120V AC Coupled / Dedicated Transformer

Which Competing Grid-Support Inverters Compare to OutBack Power: VFXR3524A {120V}?

Four alternative CEC inverters matched to OutBack Power: VFXR3524A {120V} (2,960 W AC), led by Northern Electric & Power Co Ltd: BDM-1600-LV {120V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Northern Electric & Power Co Ltd: BDM-1600-LV {120V}
Northern Electric & Power Co Ltd
1,597 W -1363 W 120.0 V 55.0 V 96.31%
Northern Electric & Power Co Ltd: BDM-1200-LV {120V}
Northern Electric & Power Co Ltd
1,194 W -1766 W 120.0 V 55.0 V 96.23%
Power Center: Essential Hybrid 5 {120V}
Power Center
4,787 W +1827 W 120.0 V 425.0 V 95.59%
Sol-Ark: 5K-120V/8K-230V-1P {120V}
Sol-Ark
4,787 W +1827 W 120.0 V 425.0 V 95.59%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for OutBack Power: VFXR3524A {120V}?

Check OutBack Power: VFXR3524A {120V} (2,960 W AC, 35 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 35 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 28 V DC on OutBack Power: VFXR3524A {120V}.

OutBack Power: VFXR3524A {120V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 35 A OCPD breaker (24.7 A continuous).

Alternative Inverter Comparison

Compare efficiency (88.54%) and MPPT window (22-28 V) directly against Northern Electric & Power Co Ltd: BDM-1600-LV {120V} (1,597 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for OutBack Power: VFXR3524A {120V} by OutBack Power covering breaker sizing, MPPT limits, and 120 V interconnection.

What breaker and wire size does OutBack Power: VFXR3524A {120V} require?

At 2,960 W continuous AC (120 V), continuous current is 24.7 A; 125% NEC 690.8/705.12 sizing requires a 35 A breaker and 8 AWG Cu (75 C) wire.

Does OutBack Power: VFXR3524A {120V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 35 A at 120 V means 120V AC Coupled / Dedicated Transformer.

How does OutBack Power: VFXR3524A {120V} compare to Northern Electric & Power Co Ltd: BDM-1600-LV {120V}?

OutBack Power: VFXR3524A {120V} delivers 2,960 W AC at 88.54% CEC efficiency with a 28 V DC ceiling, while Northern Electric & Power Co Ltd: BDM-1600-LV {120V} outputs 1,597 W at 120 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.