OutBack Power: PHXL480-10k {480V} outputs 9,975 W AC at 480 V, 3-phase (12.0 A continuous, 15 A OCPD), ranking #314 of 2,343 CEC inverters at 98.06% efficiency with a 450-850 V MPPT window and 850 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 9,975 W
- AC Voltage
- 480 V, 3-phase
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 98.06%
How Does OutBack Power: PHXL480-10k {480V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 480 V, 3-phase grid-support overview for OutBack Power: PHXL480-10k {480V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Ranking #923 of 2,343 CEC inverters (top 39.5%; higher than 60.5% of peers), OutBack Power: PHXL480-10k {480V} is a grid-tied PV inverter delivering 9,975 W continuous AC at 480 V, 3-phase (12.0 A continuous). Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 98.06% (+0.04 pts vs the 98.02% 480 V median) against peers like Fronius International GmbH: Fronius Symo 100-3 480 {480V} (9,995 W).
Where Does OutBack Power: PHXL480-10k {480V} Fall Across Listed CEC Models?
Marks OutBack Power: PHXL480-10k {480V} (9,975 W AC) across the California Energy Commission inverter AC capacity distribution. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Dataset Percentiles Define OutBack Power: PHXL480-10k {480V}?
Benchmarks OutBack Power: PHXL480-10k {480V} continuous AC output, 98.06% CEC weighted efficiency, and 15 A OCPD breaker demand.
What Do the Dataset Ranks Show for OutBack Power: PHXL480-10k {480V}?
Four key NEC 705.12 and California Energy Commission metrics defining OutBack Power: PHXL480-10k {480V} by OutBack Power. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
98.06% CEC Weighted Efficiency
+0.04 pts vs the 98.02% 480 V median; overall power rank #923 (9,975 W, top 39.5%; higher than 60.5% of peers).
15 A Required Backfeed OCPD
125% x 12.0 A = 15.0 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
450 V - 850 V (Max 850 V DC)
Tracking span of 400.0 V; active in CEC directory (grid-tied PV inverter).
PASS (120% Commercial Busbar)
Evaluated for 480 V, 3-phase switchgear (200A Bus / 200A Main (480V) to 1,200A Bus / 1,200A Main (480V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 9975.0W / 480 V 3-phase -> 12.0 A | Breaker >= 1.25 * 12.0 = 15.0 A -> 15 A
CEC Inverters.csv for OutBack Power: PHXL480-10k {480V}: Paco=9975.0 W, Vac=480 V, Vdcmax=850.0 V, Eff=98.06%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 1,200A Bus / 1,200A Main (480V): PASS (120% Commercial Busbar).
What Are the Published CEC Specifications for OutBack Power: PHXL480-10k {480V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for OutBack Power: PHXL480-10k {480V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 9,975 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 480 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 850 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 450 V - 850 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 13.5625 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.06% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: No (Grid-Tied PV) | CEC Solar Equipment List grid-support certification |
What Switchgear Limits Apply to OutBack Power: PHXL480-10k {480V} (480 V, 3-phase)?
Evaluates OutBack Power: PHXL480-10k {480V} (15 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (480V) | 40 A | 15 A | PASS (120% Commercial Busbar) |
| 400A Bus / 400A Main (480V) | 80 A | 15 A | PASS (120% Commercial Busbar) |
| 600A Bus / 600A Main (480V) | 120 A | 15 A | PASS (120% Commercial Busbar) |
| 800A Bus / 800A Main (480V) | 160 A | 15 A | PASS (120% Commercial Busbar) |
| 1,200A Bus / 1,200A Main (480V) | 240 A | 15 A | PASS (120% Commercial Busbar) |
Which CEC PV Module Strings Pair With OutBack Power: PHXL480-10k {480V}?
Sample PV string lengths aligned within 450-850 V MPPT and 850 V DC max at -10 C. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 11 to 15 panels | 8.85 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 14 to 20 panels | 8.8 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 14 to 18 panels | 7.65 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 16 to 20 panels | 4.0 kW |
Which Competing Grid-Support Inverters Compare to OutBack Power: PHXL480-10k {480V}?
Competing CEC grid-support inverters near 9,975 W AC and 480 V, 3-phase, led by Fronius International GmbH: Fronius Symo 100-3 480 {480V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Fronius International GmbH: Fronius Symo 100-3 480 {480V} Fronius International GmbH |
9,995 W | +20 W | 480.0 V | 800.0 V | 97.42% |
| Fronius International GmbH: Fronius Symo 125-3 480 {480V} Fronius International GmbH |
12,500 W | +2525 W | 480.0 V | 800.0 V | 97.57% |
| Fronius International GmbH: Fronius Symo 150-3 480 {480V} Fronius International GmbH |
15,000 W | +5025 W | 480.0 V | 800.0 V | 97.47% |
| Fronius International GmbH: Fronius Symo Advanced 150-3 480 {480V} Fronius International GmbH |
15,197 W | +5222 W | 480.0 V | 800.0 V | 97.48% |
What Are the Interconnection Limits and Best-Fit Uses for OutBack Power: PHXL480-10k {480V}?
Check OutBack Power: PHXL480-10k {480V} (9,975 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 480 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (480V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 850 V DC on OutBack Power: PHXL480-10k {480V}.
OutBack Power: PHXL480-10k {480V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (12.0 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.06%) and MPPT window (450-850 V) directly against Fronius International GmbH: Fronius Symo 100-3 480 {480V} (9,995 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for OutBack Power: PHXL480-10k {480V} by OutBack Power covering breaker sizing, MPPT limits, and 480 V, 3-phase interconnection.
What breaker and wire size does OutBack Power: PHXL480-10k {480V} require?
At 9,975 W continuous AC (480 V, 3-phase), continuous current is 12.0 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
What commercial switchgear or feeder sizing does OutBack Power: PHXL480-10k {480V} require?
At 9,975 W AC and 480 V, 3-phase, continuous line current is 12.0 A, requiring a 15 A OCPD and 1,200A Bus / 1,200A Main (480V) or NEC 705.11 interconnection.
How does OutBack Power: PHXL480-10k {480V} compare to Fronius International GmbH: Fronius Symo 100-3 480 {480V}?
OutBack Power: PHXL480-10k {480V} delivers 9,975 W AC at 98.06% CEC efficiency with a 850 V DC ceiling, while Fronius International GmbH: Fronius Symo 100-3 480 {480V} outputs 9,995 W at 480 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)