OutBack Power: SBX5048-120/240 {240V} outputs 4,985 W AC at 240 V (20.8 A continuous, 30 A OCPD), ranking #2,289 of 2,343 CEC inverters at 94.45% efficiency with a 250-550 V MPPT window and 550 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 4,985 W
- AC Voltage
- 240 V
- Min PV Breaker
- 30 A (10 AWG Cu)
- CEC Efficiency
- 94.45%
How Does OutBack Power: SBX5048-120/240 {240V} Compare Against Peer CEC Listings?
Breaker sizing (30 A), 10 AWG Cu wire rules, and DC input limits for OutBack Power: SBX5048-120/240 {240V}.
For NEC 705.12 solar interconnection, OutBack Power: SBX5048-120/240 {240V} outputs 20.8 A continuous AC at 240 V and needs a 30 A backfeed breaker on 10 AWG Cu (75 C). Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Conversion efficiency scores 94.45% (#2,289 of 2,343, -2.37 pts vs overall CEC median).
Where Does OutBack Power: SBX5048-120/240 {240V} Fall Across Listed CEC Models?
Output power comparison showing where OutBack Power: SBX5048-120/240 {240V} sits among all 2,343 CEC-listed grid-support inverters. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define OutBack Power: SBX5048-120/240 {240V}?
Relative ranking of OutBack Power: SBX5048-120/240 {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.
What Do the Dataset Ranks Show for OutBack Power: SBX5048-120/240 {240V}?
Snapshot of OutBack Power: SBX5048-120/240 {240V} efficiency rank (#2,289), OCPD breaker size, MPPT span, and busbar verdict.
94.45% CEC Weighted Efficiency
-2.23 pts vs the 96.68% 240 V median; overall power rank #1,558 (4,985 W, below CEC median; higher than 33.5% of peers).
30 A Required Backfeed OCPD
125% x 20.8 A = 26.0 A -> 30 A standard OCPD using 10 AWG Cu (75 C).
250 V - 550 V (Max 550 V DC)
Tracking span of 300.0 V; listed since 2021-03-11 (hybrid battery-capable inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 4985.0W / 240 V -> 20.8 A | Breaker >= 1.25 * 20.8 = 26.0 A -> 30 A
CEC Inverters.csv for OutBack Power: SBX5048-120/240 {240V}: Paco=4985.0 W, Vac=240 V, Vdcmax=550.0 V, Eff=94.45%.
Result: Min 30 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for OutBack Power: SBX5048-120/240 {240V}?
Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for OutBack Power: SBX5048-120/240 {240V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 4,985 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 550 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 250 V - 550 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 12.567 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 94.45% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2021-03-11 / Hybrid: Yes (Battery Capable) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for OutBack Power: SBX5048-120/240 {240V}?
NEC 705.12(B)(3)(2) backfeed compliance table for OutBack Power: SBX5048-120/240 {240V} at 240 V. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 30 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 30 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 30 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 30 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 30 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With OutBack Power: SBX5048-120/240 {240V}?
Minimum and maximum series solar module strings fitting OutBack Power: SBX5048-120/240 {240V} MPPT and 550 V limits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 6 to 9 panels | 5.31 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 8 to 13 panels | 5.72 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 8 to 12 panels | 5.1 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 9 to 13 panels | 2.6 kW |
Which Competing Grid-Support Inverters Compare to OutBack Power: SBX5048-120/240 {240V}?
Peer 240 V CEC inverters near 4,985 W AC output such as Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V} Afore New Energy Technology (Shanghai) Co Ltd |
4,998 W | +13 W | 240.0 V | 480.0 V | 97.76% |
| ABB: PVI-5000-OUTD-US-A {240V} ABB |
5,000 W | +15 W | 240.0 V | 480.0 V | 96.33% |
| ABB: PVI-5000-OUTD-US-Z-A {240V} ABB |
5,000 W | +15 W | 240.0 V | 480.0 V | 96.33% |
| ABB: PVI-5000-OUTD-US-Z-M-A {240V} ABB |
5,000 W | +15 W | 240.0 V | 480.0 V | 96.33% |
What Are the Interconnection Limits and Best-Fit Uses for OutBack Power: SBX5048-120/240 {240V}?
Check OutBack Power: SBX5048-120/240 {240V} (4,985 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 550 V DC on OutBack Power: SBX5048-120/240 {240V}.
OutBack Power: SBX5048-120/240 {240V} Panel & Wire Spec
Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (20.8 A continuous).
Alternative Inverter Comparison
Compare efficiency (94.45%) and MPPT window (250-550 V) directly against Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V} (4,998 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for OutBack Power: SBX5048-120/240 {240V} by OutBack Power covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does OutBack Power: SBX5048-120/240 {240V} require?
At 4,985 W continuous AC (240 V), continuous current is 20.8 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.
Does OutBack Power: SBX5048-120/240 {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 30 A at 240 V means PASS (120% Rule).
How does OutBack Power: SBX5048-120/240 {240V} compare to Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V}?
OutBack Power: SBX5048-120/240 {240V} delivers 4,985 W AC at 94.45% CEC efficiency with a 550 V DC ceiling, while Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V} outputs 4,998 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)