Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

OutBack Power: SBX5048-120/240 {240V} — CEC Inverter Specifications

Manufacturer: OutBack Power Registry: CEC Verified Engineering Specification

OutBack Power: SBX5048-120/240 {240V} outputs 4,985 W AC at 240 V (20.8 A continuous, 30 A OCPD), ranking #2,289 of 2,343 CEC inverters at 94.45% efficiency with a 250-550 V MPPT window and 550 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
4,985 W
AC Voltage
240 V
Min PV Breaker
30 A (10 AWG Cu)
CEC Efficiency
94.45%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does OutBack Power: SBX5048-120/240 {240V} Compare Against Peer CEC Listings?

Breaker sizing (30 A), 10 AWG Cu wire rules, and DC input limits for OutBack Power: SBX5048-120/240 {240V}.

For NEC 705.12 solar interconnection, OutBack Power: SBX5048-120/240 {240V} outputs 20.8 A continuous AC at 240 V and needs a 30 A backfeed breaker on 10 AWG Cu (75 C). Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Conversion efficiency scores 94.45% (#2,289 of 2,343, -2.37 pts vs overall CEC median).

Where Does OutBack Power: SBX5048-120/240 {240V} Fall Across Listed CEC Models?

Output power comparison showing where OutBack Power: SBX5048-120/240 {240V} sits among all 2,343 CEC-listed grid-support inverters. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where OutBack Power: SBX5048-120/240 {240V} (4,985 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACOutBack Power: SBX: 4,985 W

What Dataset Percentiles Define OutBack Power: SBX5048-120/240 {240V}?

Relative ranking of OutBack Power: SBX5048-120/240 {240V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

OutBack Power: SBX5048-120/240 {240V} Technical ThresholdsPercentile comparison for OutBack Power: SBX5048-120/240 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output4,985 WCEC Efficiency94.45%Backfeed Breaker30 A

What Do the Dataset Ranks Show for OutBack Power: SBX5048-120/240 {240V}?

Snapshot of OutBack Power: SBX5048-120/240 {240V} efficiency rank (#2,289), OCPD breaker size, MPPT span, and busbar verdict.

Eff #2,289 / 2,343

94.45% CEC Weighted Efficiency

-2.23 pts vs the 96.68% 240 V median; overall power rank #1,558 (4,985 W, below CEC median; higher than 33.5% of peers).

NEC 705.12 Check

30 A Required Backfeed OCPD

125% x 20.8 A = 26.0 A -> 30 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

250 V - 550 V (Max 550 V DC)

Tracking span of 300.0 V; listed since 2021-03-11 (hybrid battery-capable inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 4985.0W / 240 V -> 20.8 A | Breaker >= 1.25 * 20.8 = 26.0 A -> 30 A

CEC Inverters.csv for OutBack Power: SBX5048-120/240 {240V}: Paco=4985.0 W, Vac=240 V, Vdcmax=550.0 V, Eff=94.45%.

Result: Min 30 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for OutBack Power: SBX5048-120/240 {240V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for OutBack Power: SBX5048-120/240 {240V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for OutBack Power: SBX5048-120/240 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 4,985 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 550 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 250 V - 550 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 12.567 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 94.45% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2021-03-11 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for OutBack Power: SBX5048-120/240 {240V}?

NEC 705.12(B)(3)(2) backfeed compliance table for OutBack Power: SBX5048-120/240 {240V} at 240 V. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Evaluates OutBack Power: SBX5048-120/240 {240V} (30 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 30 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 30 A PASS (120% Rule)
200A Bus / 200A Main 40 A 30 A PASS (120% Rule)
200A Bus / 175A Main 65 A 30 A PASS (120% Rule)
225A Bus / 200A Main 70 A 30 A PASS (120% Rule)

Which CEC PV Module Strings Pair With OutBack Power: SBX5048-120/240 {240V}?

Minimum and maximum series solar module strings fitting OutBack Power: SBX5048-120/240 {240V} MPPT and 550 V limits.

Sampled CEC PV modules aligned within 250.0-550.0 V MPPT and 550.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 6 to 9 panels 5.31 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 8 to 13 panels 5.72 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 8 to 12 panels 5.1 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 9 to 13 panels 2.6 kW

Which Competing Grid-Support Inverters Compare to OutBack Power: SBX5048-120/240 {240V}?

Peer 240 V CEC inverters near 4,985 W AC output such as Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V}
Afore New Energy Technology (Shanghai) Co Ltd
4,998 W +13 W 240.0 V 480.0 V 97.76%
ABB: PVI-5000-OUTD-US-A {240V}
ABB
5,000 W +15 W 240.0 V 480.0 V 96.33%
ABB: PVI-5000-OUTD-US-Z-A {240V}
ABB
5,000 W +15 W 240.0 V 480.0 V 96.33%
ABB: PVI-5000-OUTD-US-Z-M-A {240V}
ABB
5,000 W +15 W 240.0 V 480.0 V 96.33%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for OutBack Power: SBX5048-120/240 {240V}?

Check OutBack Power: SBX5048-120/240 {240V} (4,985 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 550 V DC on OutBack Power: SBX5048-120/240 {240V}.

OutBack Power: SBX5048-120/240 {240V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (20.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (94.45%) and MPPT window (250-550 V) directly against Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V} (4,998 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for OutBack Power: SBX5048-120/240 {240V} by OutBack Power covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does OutBack Power: SBX5048-120/240 {240V} require?

At 4,985 W continuous AC (240 V), continuous current is 20.8 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.

Does OutBack Power: SBX5048-120/240 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 30 A at 240 V means PASS (120% Rule).

How does OutBack Power: SBX5048-120/240 {240V} compare to Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V}?

OutBack Power: SBX5048-120/240 {240V} delivers 4,985 W AC at 94.45% CEC efficiency with a 550 V DC ceiling, while Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V} outputs 4,998 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.