ABB: PVI-5000-OUTD-US-Z-A {240V} outputs 5,000 W AC at 240 V (20.8 A continuous, 30 A OCPD), ranking #1,732 of 2,343 CEC inverters at 96.33% efficiency with a 100-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 5,000 W
- AC Voltage
- 240 V
- Min PV Breaker
- 30 A (10 AWG Cu)
- CEC Efficiency
- 96.33%
How Does ABB: PVI-5000-OUTD-US-Z-A {240V} Compare Against Peer CEC Listings?
CEC efficiency rank (#1,732), 100-480 V MPPT tracking, and panel fit for ABB: PVI-5000-OUTD-US-Z-A {240V}. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
ABB: PVI-5000-OUTD-US-Z-A {240V} from ABB outputs 20.8 A continuous AC at 240 V (5,000 W AC, rank #1,516). Paired with 10 AWG Cu conductors and a 30 A OCPD, its 96.33% CEC efficiency compares closely with Delta Electronics: E6-TL-US(AC) {240V} (5,000 W). Keep NEC 690.7 winter string Voc below 480 V DC.
Where Does ABB: PVI-5000-OUTD-US-Z-A {240V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting ABB: PVI-5000-OUTD-US-Z-A {240V} at 5,000 W continuous AC output. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Dataset Percentiles Define ABB: PVI-5000-OUTD-US-Z-A {240V}?
Dataset percentiles comparing ABB: PVI-5000-OUTD-US-Z-A {240V} against 2,343 certified grid-support inverters nationwide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Do the Dataset Ranks Show for ABB: PVI-5000-OUTD-US-Z-A {240V}?
Engineering highlights for ABB: PVI-5000-OUTD-US-Z-A {240V} covering efficiency, 10 AWG Cu feeder, and panel compatibility. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
96.33% CEC Weighted Efficiency
-0.35 pts vs the 96.68% 240 V median; overall power rank #1,516 (5,000 W, below CEC median; higher than 33.9% of peers).
30 A Required Backfeed OCPD
125% x 20.8 A = 26.0 A -> 30 A standard OCPD using 10 AWG Cu (75 C).
100 V - 480 V (Max 480 V DC)
Tracking span of 380.0 V; listed since 2018-10-15 (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 5000.0W / 240 V -> 20.8 A | Breaker >= 1.25 * 20.8 = 26.0 A -> 30 A
CEC Inverters.csv for ABB: PVI-5000-OUTD-US-Z-A {240V}: Paco=5000.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.33%.
Result: Min 30 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for ABB: PVI-5000-OUTD-US-Z-A {240V}?
California Energy Commission Solar Equipment List parameters for ABB: PVI-5000-OUTD-US-Z-A {240V} (grid-tied PV inverter) interconnection. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 5,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 100 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 15.0443 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.33% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2018-10-15 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for ABB: PVI-5000-OUTD-US-Z-A {240V}?
Panelboard and switchgear backfeed allowances for ABB: PVI-5000-OUTD-US-Z-A {240V} (30 A OCPD). Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 30 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 30 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 30 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 30 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 30 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With ABB: PVI-5000-OUTD-US-Z-A {240V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for ABB: PVI-5000-OUTD-US-Z-A {240V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 3 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 3 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 3 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 4 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to ABB: PVI-5000-OUTD-US-Z-A {240V}?
Four alternative CEC inverters matched to ABB: PVI-5000-OUTD-US-Z-A {240V} (5,000 W AC), led by Delta Electronics: E6-TL-US(AC) {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Delta Electronics: E6-TL-US(AC) {240V} Delta Electronics |
5,000 W | Tie (0 W) | 240.0 V | 480.0 V | 98.02% |
| Afore New Energy Technology (Shanghai) Co Ltd: AF5K-DH {240V} Afore New Energy Technology (Shanghai) Co Ltd |
4,998 W | -2 W | 240.0 V | 480.0 V | 97.76% |
| Altenergy Power System Inc: ELS-5K {240V} Altenergy Power System Inc |
5,008 W | +8 W | 240.0 V | 60.0 V | 93.21% |
| Dyness Digital Energy Technology Co LTD: TX5K-HM {240V} Dyness Digital Energy Technology Co LTD |
5,020 W | +20 W | 240.0 V | 500.0 V | 97.05% |
What Are the Interconnection Limits and Best-Fit Uses for ABB: PVI-5000-OUTD-US-Z-A {240V}?
Check ABB: PVI-5000-OUTD-US-Z-A {240V} (5,000 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on ABB: PVI-5000-OUTD-US-Z-A {240V}.
ABB: PVI-5000-OUTD-US-Z-A {240V} Panel & Wire Spec
Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (20.8 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.33%) and MPPT window (100-480 V) directly against Delta Electronics: E6-TL-US(AC) {240V} (5,000 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for ABB: PVI-5000-OUTD-US-Z-A {240V} by ABB covering breaker sizing, MPPT limits, and 240 V interconnection. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What breaker and wire size does ABB: PVI-5000-OUTD-US-Z-A {240V} require?
At 5,000 W continuous AC (240 V), continuous current is 20.8 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.
Does ABB: PVI-5000-OUTD-US-Z-A {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 30 A at 240 V means PASS (120% Rule).
How does ABB: PVI-5000-OUTD-US-Z-A {240V} compare to Delta Electronics: E6-TL-US(AC) {240V}?
ABB: PVI-5000-OUTD-US-Z-A {240V} delivers 5,000 W AC at 96.33% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: E6-TL-US(AC) {240V} outputs 5,000 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)