ABB: PVS-166-TL-POWER-MODULE-1-US {800V} — CEC Inverter Specifications

Manufacturer: ABB Registry: CEC Verified Engineering Specification

ABB: PVS-166-TL-POWER-MODULE-1-US {800V} outputs 165,954 W AC at 800 V, 3-phase (119.8 A continuous, 150 A OCPD), ranking #210 of 2,343 CEC inverters at 98.26% efficiency with a 850-1,200 V MPPT window and 1,200 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
165,954 W
AC Voltage
800 V, 3-phase
Min PV Breaker
150 A (1/0 AWG Cu)
CEC Efficiency
98.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does ABB: PVS-166-TL-POWER-MODULE-1-US {800V} Compare Against Peer CEC Listings?

How ABB ABB: PVS-166-TL-POWER-MODULE-1-US {800V} compares on 98.26% efficiency, MPPT span, and 120% busbar interconnection. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

With a 850-1,200 V MPPT tracking band and 1,200 V DC ceiling, ABB: PVS-166-TL-POWER-MODULE-1-US {800V} handles 165,954 W continuous AC (154,046 W below the 320,000 W 800 V median). Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap. Installers comparing ABB against Chint Power Systems America: CPS ECB200KTL/US-800 {800V} (200,000 W) should verify whether listed since 2020-09-01 grid-support firmware meets local IEEE 1547 utility rules.

Where Does ABB: PVS-166-TL-POWER-MODULE-1-US {800V} Fall Across Listed CEC Models?

Position of ABB: PVS-166-TL-POWER-MODULE-1-US {800V} (165,954 W AC) relative to the 7,680 W CEC median inverter. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where ABB: PVS-166-TL-POWER-MODULE-1-US {800V} (165,954 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACABB: PVS-166-TL-PO: 165,954 W

What Dataset Percentiles Define ABB: PVS-166-TL-POWER-MODULE-1-US {800V}?

Percentile placement of ABB: PVS-166-TL-POWER-MODULE-1-US {800V} across AC power class, conversion efficiency, and backfeed breaker size. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

ABB: PVS-166-TL-POWER-MODULE-1-US {800V} Technical ThresholdsPercentile comparison for ABB: PVS-166-TL-POWER-MODULE-1-US {800V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output165,954 WCEC Efficiency98.26%Backfeed Breaker150 A

What Do the Dataset Ranks Show for ABB: PVS-166-TL-POWER-MODULE-1-US {800V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for ABB: PVS-166-TL-POWER-MODULE-1-US {800V}. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Eff #210 / 2,343

98.26% CEC Weighted Efficiency

-0.04 pts vs the 98.3% 800 V median; overall power rank #265 (165,954 W, top 11.4%; higher than 88.6% of peers).

NEC 705.12 Check

150 A Required Backfeed OCPD

125% x 119.8 A = 149.8 A -> 150 A standard OCPD using 1/0 AWG Cu (75 C).

MPPT Window

850 V - 1,200 V (Max 1,200 V DC)

Tracking span of 350.0 V; listed since 2020-09-01 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 800 V, 3-phase switchgear (200A Bus / 200A Main (800V) to 1,200A Bus / 1,200A Main (800V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 165954.0W / 800 V 3-phase -> 119.8 A | Breaker >= 1.25 * 119.8 = 149.8 A -> 150 A

CEC Inverters.csv for ABB: PVS-166-TL-POWER-MODULE-1-US {800V}: Paco=165954.0 W, Vac=800 V, Vdcmax=1200.0 V, Eff=98.26%.

Result: Min 150 A breaker & 1/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (800V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for ABB: PVS-166-TL-POWER-MODULE-1-US {800V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for ABB: PVS-166-TL-POWER-MODULE-1-US {800V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for ABB: PVS-166-TL-POWER-MODULE-1-US {800V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 165,954 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 800 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,200 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 850 V - 1,200 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 153.534 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 98.26% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2020-09-01 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to ABB: PVS-166-TL-POWER-MODULE-1-US {800V} (800 V, 3-phase)?

Check whether ABB: PVS-166-TL-POWER-MODULE-1-US {800V} (150 A breaker) fits without main breaker derate or supply-side taps. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Evaluates ABB: PVS-166-TL-POWER-MODULE-1-US {800V} (150 A required OCPD at 800 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (800V) 40 A 150 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (800V) 80 A 150 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (800V) 120 A 150 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (800V) 160 A 150 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (800V) 240 A 150 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With ABB: PVS-166-TL-POWER-MODULE-1-US {800V}?

Verified cold-weather (-10 C) series module counts matched to ABB: PVS-166-TL-POWER-MODULE-1-US {800V}'s 1,200 V DC ceiling. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sampled CEC PV modules aligned within 850.0-1200.0 V MPPT and 1200.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 20 to 21 panels 12.39 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 26 to 28 panels 12.32 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 25 to 26 panels 11.05 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 21 to 22 panels 11.33 kW

Which Competing Grid-Support Inverters Compare to ABB: PVS-166-TL-POWER-MODULE-1-US {800V}?

Alternative CEC inverters comparable to ABB: PVS-166-TL-POWER-MODULE-1-US {800V}, including Chint Power Systems America: CPS ECB200KTL/US-800 {800V} (200,000 W) at 800 V, 3-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Chint Power Systems America: CPS ECB200KTL/US-800 {800V}
Chint Power Systems America
200,000 W +34046 W 800.0 V 1500.0 V 97.55%
Sungrow Power Supply Co Ltd: SG250HX-US {800V}
Sungrow Power Supply Co Ltd
226,997 W +61043 W 800.0 V 1300.0 V 98.52%
Huawei Technologies Co Ltd: SUN2000-100KTL-USH0 {800V}
Huawei Technologies Co Ltd
100,000 W -65954 W 800.0 V 1200.0 V 98.57%
Ginlong Technologies Co Ltd: Solis-255K-EHV-5G-US-PLUS {800V}
Ginlong Technologies Co Ltd
238,706 W +72752 W 800.0 V 1300.0 V 98.26%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for ABB: PVS-166-TL-POWER-MODULE-1-US {800V}?

Check ABB: PVS-166-TL-POWER-MODULE-1-US {800V} (165,954 W AC, 150 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,200 V DC on ABB: PVS-166-TL-POWER-MODULE-1-US {800V}.

ABB: PVS-166-TL-POWER-MODULE-1-US {800V} Panel & Wire Spec

Size 75 C copper conductors at 1/0 AWG Cu on a 150 A OCPD breaker (119.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (98.26%) and MPPT window (850-1,200 V) directly against Chint Power Systems America: CPS ECB200KTL/US-800 {800V} (200,000 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for ABB: PVS-166-TL-POWER-MODULE-1-US {800V} by ABB covering breaker sizing, MPPT limits, and 800 V, 3-phase interconnection. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

What breaker and wire size does ABB: PVS-166-TL-POWER-MODULE-1-US {800V} require?

At 165,954 W continuous AC (800 V, 3-phase), continuous current is 119.8 A; 125% NEC 690.8/705.12 sizing requires a 150 A breaker and 1/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does ABB: PVS-166-TL-POWER-MODULE-1-US {800V} require?

At 165,954 W AC and 800 V, 3-phase, continuous line current is 119.8 A, requiring a 150 A OCPD and 1,200A Bus / 1,200A Main (800V) or NEC 705.11 interconnection.

How does ABB: PVS-166-TL-POWER-MODULE-1-US {800V} compare to Chint Power Systems America: CPS ECB200KTL/US-800 {800V}?

ABB: PVS-166-TL-POWER-MODULE-1-US {800V} delivers 165,954 W AC at 98.26% CEC efficiency with a 1,200 V DC ceiling, while Chint Power Systems America: CPS ECB200KTL/US-800 {800V} outputs 200,000 W at 800 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.