Manufacturer: Chint Power Systems America Registry: CEC Verified Engineering Specification

Chint Power Systems America: CPS ECB200KTL/US-800 {800V} outputs 200,000 W AC at 800 V, 3-phase (144.3 A continuous, 200 A OCPD), ranking #529 of 2,343 CEC inverters at 97.55% efficiency with a 950-1,500 V MPPT window and 1,500 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
200,000 W
AC Voltage
800 V, 3-phase
Min PV Breaker
200 A (3/0 AWG Cu)
CEC Efficiency
97.55%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Chint Power Systems America: CPS ECB200KTL/US-800 {800V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 800 V, 3-phase grid-support overview for Chint Power Systems America: CPS ECB200KTL/US-800 {800V}.

Ranking #247 of 2,343 CEC inverters (top 10.7%; higher than 89.3% of peers), Chint Power Systems America: CPS ECB200KTL/US-800 {800V} is a grid-tied PV inverter delivering 200,000 W continuous AC at 800 V, 3-phase (144.3 A continuous). Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap. Weighted CEC efficiency reaches 97.55% (-0.75 pts vs the 98.3% 800 V median) against peers like ABB: PVS-175-TL-POWER-MODULE-1-US {800V} (179,574 W).

Where Does Chint Power Systems America: CPS ECB200KTL/US-800 {800V} Fall Across Listed CEC Models?

Marks Chint Power Systems America: CPS ECB200KTL/US-800 {800V} (200,000 W AC) across the California Energy Commission inverter AC capacity distribution.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Chint Power Systems America: CPS ECB200KTL/US-800 {800V} (200,000 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACChint Power System: 200,000 W

What Dataset Percentiles Define Chint Power Systems America: CPS ECB200KTL/US-800 {800V}?

Benchmarks Chint Power Systems America: CPS ECB200KTL/US-800 {800V} continuous AC output, 97.55% CEC weighted efficiency, and 200 A OCPD breaker demand.

Chint Power Systems America: CPS ECB200KTL/US-800 {800V} Technical ThresholdsPercentile comparison for Chint Power Systems America: CPS ECB200KTL/US-800 {800V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output200,000 WCEC Efficiency97.55%Backfeed Breaker200 A

What Do the Dataset Ranks Show for Chint Power Systems America: CPS ECB200KTL/US-800 {800V}?

Four key NEC 705.12 and California Energy Commission metrics defining Chint Power Systems America: CPS ECB200KTL/US-800 {800V} by Chint Power Systems America.

Eff #529 / 2,343

97.55% CEC Weighted Efficiency

-0.75 pts vs the 98.3% 800 V median; overall power rank #247 (200,000 W, top 10.7%; higher than 89.3% of peers).

NEC 705.12 Check

200 A Required Backfeed OCPD

125% x 144.3 A = 180.4 A -> 200 A standard OCPD using 3/0 AWG Cu (75 C).

MPPT Window

950 V - 1,500 V (Max 1,500 V DC)

Tracking span of 550.0 V; listed since 2025-03-03 (grid-tied PV inverter).

Commercial / 3-Phase Fit

Supply-Side Tap (705.11) / Dedicated Switchboard

Evaluated for 800 V, 3-phase switchgear (200A Bus / 200A Main (800V) to 1,200A Bus / 1,200A Main (800V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 200000.0W / 800 V 3-phase -> 144.3 A | Breaker >= 1.25 * 144.3 = 180.4 A -> 200 A

CEC Inverters.csv for Chint Power Systems America: CPS ECB200KTL/US-800 {800V}: Paco=200000.0 W, Vac=800 V, Vdcmax=1500.0 V, Eff=97.55%.

Result: Min 200 A breaker & 3/0 AWG Cu (75 C); 1,200A Bus / 1,200A Main (800V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Chint Power Systems America: CPS ECB200KTL/US-800 {800V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for Chint Power Systems America: CPS ECB200KTL/US-800 {800V}.

Official California Energy Commission (NREL SAM) test parameters for Chint Power Systems America: CPS ECB200KTL/US-800 {800V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 200,000 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 800 V, 3-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 1,500 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 950 V - 1,500 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 167.36 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 97.55% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-03-03 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

What Switchgear Limits Apply to Chint Power Systems America: CPS ECB200KTL/US-800 {800V} (800 V, 3-phase)?

Evaluates Chint Power Systems America: CPS ECB200KTL/US-800 {800V} (200 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates Chint Power Systems America: CPS ECB200KTL/US-800 {800V} (200 A required OCPD at 800 V, 3-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (800V) 40 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (800V) 80 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
600A Bus / 600A Main (800V) 120 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
800A Bus / 800A Main (800V) 160 A 200 A Supply-Side Tap (705.11) / Dedicated Switchboard
1,200A Bus / 1,200A Main (800V) 240 A 200 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Chint Power Systems America: CPS ECB200KTL/US-800 {800V}?

Sample PV string lengths aligned within 950-1,500 V MPPT and 1,500 V DC max at -10 C. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sampled CEC PV modules aligned within 950.0-1500.0 V MPPT and 1500.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 23 to 26 panels 15.34 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 29 to 35 panels 15.4 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 28 to 33 panels 14.03 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 33 to 36 panels 7.2 kW

Which Competing Grid-Support Inverters Compare to Chint Power Systems America: CPS ECB200KTL/US-800 {800V}?

Competing CEC grid-support inverters near 200,000 W AC and 800 V, 3-phase, led by ABB: PVS-175-TL-POWER-MODULE-1-US {800V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
ABB: PVS-175-TL-POWER-MODULE-1-US {800V}
ABB
179,574 W -20426 W 800.0 V 1200.0 V 97.39%
ABB: PVS-175-TL-POWER-MODULE-2-US {800V}
ABB
179,574 W -20426 W 800.0 V 1200.0 V 97.39%
Sungrow Power Supply Co Ltd: SG250HX-US {800V}
Sungrow Power Supply Co Ltd
226,997 W +26997 W 800.0 V 1300.0 V 98.52%
ABB: PVS-166-TL-POWER-MODULE-1-US {800V}
ABB
165,954 W -34046 W 800.0 V 1200.0 V 98.26%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Chint Power Systems America: CPS ECB200KTL/US-800 {800V}?

Check Chint Power Systems America: CPS ECB200KTL/US-800 {800V} (200,000 W AC, 200 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,500 V DC on Chint Power Systems America: CPS ECB200KTL/US-800 {800V}.

Chint Power Systems America: CPS ECB200KTL/US-800 {800V} Panel & Wire Spec

Size 75 C copper conductors at 3/0 AWG Cu on a 200 A OCPD breaker (144.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (97.55%) and MPPT window (950-1,500 V) directly against ABB: PVS-175-TL-POWER-MODULE-1-US {800V} (179,574 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Chint Power Systems America: CPS ECB200KTL/US-800 {800V} by Chint Power Systems America covering breaker sizing, MPPT limits, and 800 V, 3-phase interconnection.

What breaker and wire size does Chint Power Systems America: CPS ECB200KTL/US-800 {800V} require?

At 200,000 W continuous AC (800 V, 3-phase), continuous current is 144.3 A; 125% NEC 690.8/705.12 sizing requires a 200 A breaker and 3/0 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Chint Power Systems America: CPS ECB200KTL/US-800 {800V} require?

At 200,000 W AC and 800 V, 3-phase, continuous line current is 144.3 A, requiring a 200 A OCPD and 1,200A Bus / 1,200A Main (800V) or NEC 705.11 interconnection.

How does Chint Power Systems America: CPS ECB200KTL/US-800 {800V} compare to ABB: PVS-175-TL-POWER-MODULE-1-US {800V}?

Chint Power Systems America: CPS ECB200KTL/US-800 {800V} delivers 200,000 W AC at 97.55% CEC efficiency with a 1,500 V DC ceiling, while ABB: PVS-175-TL-POWER-MODULE-1-US {800V} outputs 179,574 W at 800 V, 3-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.