Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} outputs 320,000 W AC at 800 V, 3-phase (230.9 A continuous, 300 A OCPD), ranking #188 of 2,343 CEC inverters at 98.3% efficiency with a 880-1,300 V MPPT window and 1,300 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 320,000 W
- AC Voltage
- 800 V, 3-phase
- Min PV Breaker
- 300 A (parallel Cu feeders)
- CEC Efficiency
- 98.3%
How Does Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} Compare Against Peer CEC Listings?
CEC efficiency rank (#188), 880-1,300 V MPPT tracking, and panel fit for Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V}.
Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} from Chint Power Systems America outputs 230.9 A continuous AC at 800 V, 3-phase (320,000 W AC, rank #214). Paired with parallel Cu feeders conductors and a 300 A OCPD, its 98.3% CEC efficiency compares closely with Sungrow Power Supply Co Ltd: SG350HX-US {800V} (320,865 W). Keep NEC 690.7 winter string Voc below 1,300 V DC.
Where Does Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} at 320,000 W continuous AC output.
What Dataset Percentiles Define Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V}?
Dataset percentiles comparing Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} against 2,343 certified grid-support inverters nationwide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V}?
Engineering highlights for Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} covering efficiency, parallel Cu feeders feeder, and panel compatibility.
98.3% CEC Weighted Efficiency
equal to the 98.3% 800 V median; overall power rank #214 (320,000 W, top 9.1%; higher than 90.9% of peers).
300 A Required Backfeed OCPD
125% x 230.9 A = 288.6 A -> 300 A standard OCPD using parallel Cu feeders (75 C).
880 V - 1,300 V (Max 1,300 V DC)
Tracking span of 420.0 V; listed since 2024-07-01 (grid-tied PV inverter).
Supply-Side Tap (705.11) / Dedicated Switchboard
Evaluated for 800 V, 3-phase switchgear (200A Bus / 200A Main (800V) to 1,200A Bus / 1,200A Main (800V)) under NEC 705.12 / 705.11.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 320000.0W / 800 V 3-phase -> 230.9 A | Breaker >= 1.25 * 230.9 = 288.6 A -> 300 A
CEC Inverters.csv for Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V}: Paco=320000.0 W, Vac=800 V, Vdcmax=1300.0 V, Eff=98.3%.
Result: Min 300 A breaker & parallel Cu feeders (75 C); 1,200A Bus / 1,200A Main (800V): Supply-Side Tap (705.11) / Dedicated Switchboard.
What Are the Published CEC Specifications for Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V}?
California Energy Commission Solar Equipment List parameters for Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} (grid-tied PV inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 320,000 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 800 V, 3-phase | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 1,300 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 880 V - 1,300 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 273.567 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 98.3% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2024-07-01 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
What Switchgear Limits Apply to Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} (800 V, 3-phase)?
Panelboard and switchgear backfeed allowances for Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} (300 A OCPD). Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Switchboard / Interconnect | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 200A Bus / 200A Main (800V) | 40 A | 300 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 400A Bus / 400A Main (800V) | 80 A | 300 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 600A Bus / 600A Main (800V) | 120 A | 300 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 800A Bus / 800A Main (800V) | 160 A | 300 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
| 1,200A Bus / 1,200A Main (800V) | 240 A | 300 A | Supply-Side Tap (705.11) / Dedicated Switchboard |
Which CEC PV Module Strings Pair With Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V}.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 21 to 23 panels | 13.57 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 27 to 30 panels | 13.2 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 26 to 29 panels | 12.32 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 31 to 32 panels | 6.4 kW |
Which Competing Grid-Support Inverters Compare to Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V}?
Four alternative CEC inverters matched to Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} (320,000 W AC), led by Sungrow Power Supply Co Ltd: SG350HX-US {800V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Sungrow Power Supply Co Ltd: SG350HX-US {800V} Sungrow Power Supply Co Ltd |
320,865 W | +865 W | 800.0 V | 1330.0 V | 98.28% |
| Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M12 {800V} Ginlong Technologies Co Ltd |
348,153 W | +28153 W | 800.0 V | 1300.0 V | 98.47% |
| Ginlong Technologies Co Ltd: S6-GU350K-EHV-US-M16 {800V} Ginlong Technologies Co Ltd |
348,488 W | +28488 W | 800.0 V | 1300.0 V | 98.47% |
| Delta Electronics: DP350U-US-XX {800V} Delta Electronics |
352,401 W | +32401 W | 800.0 V | 1330.0 V | 98.48% |
What Are the Interconnection Limits and Best-Fit Uses for Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V}?
Check Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} (320,000 W AC, 300 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Commercial 800 V, 3-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (800V) or NEC 705.11 supply-side tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 1,300 V DC on Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V}.
Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} Panel & Wire Spec
Size 75 C copper conductors at parallel Cu feeders on a 300 A OCPD breaker (230.9 A continuous).
Alternative Inverter Comparison
Compare efficiency (98.3%) and MPPT window (880-1,300 V) directly against Sungrow Power Supply Co Ltd: SG350HX-US {800V} (320,865 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} by Chint Power Systems America covering breaker sizing, MPPT limits, and 800 V, 3-phase interconnection.
What breaker and wire size does Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} require?
At 320,000 W continuous AC (800 V, 3-phase), continuous current is 230.9 A; 125% NEC 690.8/705.12 sizing requires a 300 A breaker and parallel Cu feeders (75 C) wire.
What commercial switchgear or feeder sizing does Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} require?
At 320,000 W AC and 800 V, 3-phase, continuous line current is 230.9 A, requiring a 300 A OCPD and 1,200A Bus / 1,200A Main (800V) or NEC 705.11 interconnection.
How does Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} compare to Sungrow Power Supply Co Ltd: SG350HX-US {800V}?
Chint Power Systems America: CPS SCH320KTL-DO/US-800 {800V} delivers 320,000 W AC at 98.3% CEC efficiency with a 1,300 V DC ceiling, while Sungrow Power Supply Co Ltd: SG350HX-US {800V} outputs 320,865 W at 800 V, 3-phase.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)