Manufacturer: OutBack Power Registry: CEC Verified Engineering Specification

OutBack Power: OGHI8048A {240V} outputs 7,638 W AC at 240 V (31.8 A continuous, 40 A OCPD), ranking #2,339 of 2,343 CEC inverters at 90.41% efficiency with a 44-52 V MPPT window and 52 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
7,638 W
AC Voltage
240 V
Min PV Breaker
40 A (8 AWG Cu)
CEC Efficiency
90.41%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does OutBack Power: OGHI8048A {240V} Compare Against Peer CEC Listings?

How OutBack Power OutBack Power: OGHI8048A {240V} compares on 90.41% efficiency, MPPT span, and 120% busbar interconnection. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

With a 44-52 V MPPT tracking band and 52 V DC ceiling, OutBack Power: OGHI8048A {240V} handles 7,638 W continuous AC (1,862 W above the 5,776 W 240 V median). Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Installers comparing OutBack Power against Dyness Digital Energy Technology Co LTD: TX76K-HM {240V} (7,640 W) should verify whether listed since 2023-10-11 grid-support firmware meets local IEEE 1547 utility rules.

Where Does OutBack Power: OGHI8048A {240V} Fall Across Listed CEC Models?

Position of OutBack Power: OGHI8048A {240V} (7,638 W AC) relative to the 7,680 W CEC median inverter. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where OutBack Power: OGHI8048A {240V} (7,638 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACOutBack Power: OGH: 7,638 W

What Dataset Percentiles Define OutBack Power: OGHI8048A {240V}?

Percentile placement of OutBack Power: OGHI8048A {240V} across AC power class, conversion efficiency, and backfeed breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

OutBack Power: OGHI8048A {240V} Technical ThresholdsPercentile comparison for OutBack Power: OGHI8048A {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output7,638 WCEC Efficiency90.41%Backfeed Breaker40 A

What Do the Dataset Ranks Show for OutBack Power: OGHI8048A {240V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for OutBack Power: OGHI8048A {240V}. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Eff #2,339 / 2,343

90.41% CEC Weighted Efficiency

-6.27 pts vs the 96.68% 240 V median; overall power rank #1,206 (7,638 W, below CEC median; higher than 48.5% of peers).

NEC 705.12 Check

40 A Required Backfeed OCPD

125% x 31.8 A = 39.8 A -> 40 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

44 V - 52 V (Max 52 V DC)

Tracking span of 8.0 V; listed since 2023-10-11 (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 7638.0W / 240 V -> 31.8 A | Breaker >= 1.25 * 31.8 = 39.8 A -> 40 A

CEC Inverters.csv for OutBack Power: OGHI8048A {240V}: Paco=7638.0 W, Vac=240 V, Vdcmax=52.0 V, Eff=90.41%.

Result: Min 40 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for OutBack Power: OGHI8048A {240V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for OutBack Power: OGHI8048A {240V}. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for OutBack Power: OGHI8048A {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 7,638 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 52 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 44 V - 52 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 176.005 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 90.41% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2023-10-11 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for OutBack Power: OGHI8048A {240V}?

Check whether OutBack Power: OGHI8048A {240V} (40 A breaker) fits without main breaker derate or supply-side taps. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates OutBack Power: OGHI8048A {240V} (40 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 40 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 40 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 40 A PASS (120% Rule)
200A Bus / 175A Main 65 A 40 A PASS (120% Rule)
225A Bus / 200A Main 70 A 40 A PASS (120% Rule)

Which CEC PV Module Strings Pair With OutBack Power: OGHI8048A {240V}?

Verified cold-weather (-10 C) series module counts matched to OutBack Power: OGHI8048A {240V}'s 52 V DC ceiling.

Sampled CEC PV modules aligned within 44.0-52.0 V MPPT and 52.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW 270.0 W 42.56 V 1 panel (micro/module) 0.27 kW

Which Competing Grid-Support Inverters Compare to OutBack Power: OGHI8048A {240V}?

Alternative CEC inverters comparable to OutBack Power: OGHI8048A {240V}, including Dyness Digital Energy Technology Co LTD: TX76K-HM {240V} (7,640 W) at 240 V.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Dyness Digital Energy Technology Co LTD: TX76K-HM {240V}
Dyness Digital Energy Technology Co LTD
7,640 W +2 W 240.0 V 500.0 V 96.84%
Dyness Digital Energy Technology Co LTD: TX76K-AM {240V}
Dyness Digital Energy Technology Co LTD
7,636 W -2 W 240.0 V 490.0 V 96.56%
Alpha ESS Co Ltd: SMILE-SP76-INV {240V}
Alpha ESS Co Ltd
7,644 W +6 W 240.0 V 480.0 V 97.02%
Alpha ESS Co Ltd: SMILE-SPB76-INV {240V}
Alpha ESS Co Ltd
7,648 W +10 W 240.0 V 495.0 V 96.36%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for OutBack Power: OGHI8048A {240V}?

Check OutBack Power: OGHI8048A {240V} (7,638 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 52 V DC on OutBack Power: OGHI8048A {240V}.

OutBack Power: OGHI8048A {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (31.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (90.41%) and MPPT window (44-52 V) directly against Dyness Digital Energy Technology Co LTD: TX76K-HM {240V} (7,640 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for OutBack Power: OGHI8048A {240V} by OutBack Power covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does OutBack Power: OGHI8048A {240V} require?

At 7,638 W continuous AC (240 V), continuous current is 31.8 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.

Does OutBack Power: OGHI8048A {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 40 A at 240 V means PASS (120% Rule).

How does OutBack Power: OGHI8048A {240V} compare to Dyness Digital Energy Technology Co LTD: TX76K-HM {240V}?

OutBack Power: OGHI8048A {240V} delivers 7,638 W AC at 90.41% CEC efficiency with a 52 V DC ceiling, while Dyness Digital Energy Technology Co LTD: TX76K-HM {240V} outputs 7,640 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.