OutBack Power: GS8048A {240V} — CEC Inverter Specifications

Manufacturer: OutBack Power Registry: CEC Verified Engineering Specification

OutBack Power: GS8048A {240V} outputs 7,200 W AC at 240 V (30.0 A continuous, 40 A OCPD), ranking #2,343 of 2,343 CEC inverters at 81.44% efficiency with a 44-56 V MPPT window and 56 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
7,200 W
AC Voltage
240 V
Min PV Breaker
40 A (8 AWG Cu)
CEC Efficiency
81.44%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does OutBack Power: GS8048A {240V} Compare Against Peer CEC Listings?

NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for OutBack Power: GS8048A {240V}. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Ranking #1,276 of 2,343 CEC inverters (below CEC median; higher than 45.5% of peers), OutBack Power: GS8048A {240V} is a grid-tied PV inverter delivering 7,200 W continuous AC at 240 V (30.0 A continuous). Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit). Weighted CEC efficiency reaches 81.44% (-15.24 pts vs the 96.68% 240 V median) against peers like Afore New Energy Technology (Shanghai) Co Ltd: AF7K-DH {240V} (6,996 W).

Where Does OutBack Power: GS8048A {240V} Fall Across Listed CEC Models?

Marks OutBack Power: GS8048A {240V} (7,200 W AC) across the California Energy Commission inverter AC capacity distribution. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where OutBack Power: GS8048A {240V} (7,200 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACOutBack Power: GS8: 7,200 W

What Dataset Percentiles Define OutBack Power: GS8048A {240V}?

Benchmarks OutBack Power: GS8048A {240V} continuous AC output, 81.44% CEC weighted efficiency, and 40 A OCPD breaker demand.

OutBack Power: GS8048A {240V} Technical ThresholdsPercentile comparison for OutBack Power: GS8048A {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output7,200 WCEC Efficiency81.44%Backfeed Breaker40 A

What Do the Dataset Ranks Show for OutBack Power: GS8048A {240V}?

Four key NEC 705.12 and California Energy Commission metrics defining OutBack Power: GS8048A {240V} by OutBack Power. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Eff #2,343 / 2,343

81.44% CEC Weighted Efficiency

-15.24 pts vs the 96.68% 240 V median; overall power rank #1,276 (7,200 W, below CEC median; higher than 45.5% of peers).

NEC 705.12 Check

40 A Required Backfeed OCPD

125% x 30.0 A = 37.5 A -> 40 A standard OCPD using 8 AWG Cu (75 C).

MPPT Window

44 V - 56 V (Max 56 V DC)

Tracking span of 12.0 V; listed since 2020-12-01 (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 7200.0W / 240 V -> 30.0 A | Breaker >= 1.25 * 30.0 = 37.5 A -> 40 A

CEC Inverters.csv for OutBack Power: GS8048A {240V}: Paco=7200.0 W, Vac=240 V, Vdcmax=56.0 V, Eff=81.44%.

Result: Min 40 A breaker & 8 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for OutBack Power: GS8048A {240V}?

Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for OutBack Power: GS8048A {240V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for OutBack Power: GS8048A {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 7,200 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 56 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 44 V - 56 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 184.184 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 81.44% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2020-12-01 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for OutBack Power: GS8048A {240V}?

Evaluates OutBack Power: GS8048A {240V} (40 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.

Evaluates OutBack Power: GS8048A {240V} (40 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 40 A Needs Derate / Tap 705.11
150A Bus / 150A Main 30 A 40 A Needs Derate / Tap 705.11
200A Bus / 200A Main 40 A 40 A PASS (120% Rule)
200A Bus / 175A Main 65 A 40 A PASS (120% Rule)
225A Bus / 200A Main 70 A 40 A PASS (120% Rule)

Which CEC PV Module Strings Pair With OutBack Power: GS8048A {240V}?

Sample PV string lengths aligned within 44-56 V MPPT and 56 V DC max at -10 C. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sampled CEC PV modules aligned within 44.0-56.0 V MPPT and 56.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 1 panel (micro/module) 0.52 kW

Which Competing Grid-Support Inverters Compare to OutBack Power: GS8048A {240V}?

Competing CEC grid-support inverters near 7,200 W AC and 240 V, led by Afore New Energy Technology (Shanghai) Co Ltd: AF7K-DH {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Afore New Energy Technology (Shanghai) Co Ltd: AF7K-DH {240V}
Afore New Energy Technology (Shanghai) Co Ltd
6,996 W -204 W 240.0 V 480.0 V 97.92%
Base Power Inc: MIN 7600TL-XH-US {240V}
Base Power Inc
7,524 W +324 W 240.0 V 480.0 V 97.19%
Chint Power Systems America: CPS ECH76KTL/US {240V}
Chint Power Systems America
7,570 W +370 W 240.0 V 480.0 V 96.71%
Afore New Energy Technology (Shanghai) Co Ltd: AF76K-DH {240V}
Afore New Energy Technology (Shanghai) Co Ltd
7,599 W +399 W 240.0 V 480.0 V 97.57%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for OutBack Power: GS8048A {240V}?

Check OutBack Power: GS8048A {240V} (7,200 W AC, 40 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 40 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 56 V DC on OutBack Power: GS8048A {240V}.

OutBack Power: GS8048A {240V} Panel & Wire Spec

Size 75 C copper conductors at 8 AWG Cu on a 40 A OCPD breaker (30.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (81.44%) and MPPT window (44-56 V) directly against Afore New Energy Technology (Shanghai) Co Ltd: AF7K-DH {240V} (6,996 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for OutBack Power: GS8048A {240V} by OutBack Power covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does OutBack Power: GS8048A {240V} require?

At 7,200 W continuous AC (240 V), continuous current is 30.0 A; 125% NEC 690.8/705.12 sizing requires a 40 A breaker and 8 AWG Cu (75 C) wire.

Does OutBack Power: GS8048A {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 40 A at 240 V means PASS (120% Rule).

How does OutBack Power: GS8048A {240V} compare to Afore New Energy Technology (Shanghai) Co Ltd: AF7K-DH {240V}?

OutBack Power: GS8048A {240V} delivers 7,200 W AC at 81.44% CEC efficiency with a 56 V DC ceiling, while Afore New Energy Technology (Shanghai) Co Ltd: AF7K-DH {240V} outputs 6,996 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.