OutBack Power: GS4048A {240V} outputs 3,600 W AC at 240 V (15.0 A continuous, 20 A OCPD), ranking #2,322 of 2,343 CEC inverters at 93.58% efficiency with a 44-56 V MPPT window and 56 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 3,600 W
- AC Voltage
- 240 V
- Min PV Breaker
- 20 A (12 AWG Cu)
- CEC Efficiency
- 93.58%
How Does OutBack Power: GS4048A {240V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for OutBack Power: GS4048A {240V}. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Rated at 3,600 W AC (15.0 A continuous), OutBack Power: GS4048A {240V} ranks #2,322 of 2,343 CEC units at 93.58% efficiency (-3.10 pts vs the 96.68% 240 V median). Minimum 75 C copper conductor sizing for its 20 A circuit is 12 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 56 V DC at record local winter lows.
Where Does OutBack Power: GS4048A {240V} Fall Across Listed CEC Models?
Marks OutBack Power: GS4048A {240V} (3,600 W AC) across the California Energy Commission inverter AC capacity distribution. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Dataset Percentiles Define OutBack Power: GS4048A {240V}?
Benchmarks OutBack Power: GS4048A {240V} continuous AC output, 93.58% CEC weighted efficiency, and 20 A OCPD breaker demand.
What Do the Dataset Ranks Show for OutBack Power: GS4048A {240V}?
Four key NEC 705.12 and California Energy Commission metrics defining OutBack Power: GS4048A {240V} by OutBack Power. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
93.58% CEC Weighted Efficiency
-3.10 pts vs the 96.68% 240 V median; overall power rank #1,685 (3,600 W, below CEC median; higher than 27.6% of peers).
20 A Required Backfeed OCPD
125% x 15.0 A = 18.8 A -> 20 A standard OCPD using 12 AWG Cu (75 C).
44 V - 56 V (Max 56 V DC)
Tracking span of 12.0 V; listed since 2020-12-01 (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 3600.0W / 240 V -> 15.0 A | Breaker >= 1.25 * 15.0 = 18.8 A -> 20 A
CEC Inverters.csv for OutBack Power: GS4048A {240V}: Paco=3600.0 W, Vac=240 V, Vdcmax=56.0 V, Eff=93.58%.
Result: Min 20 A breaker & 12 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for OutBack Power: GS4048A {240V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for OutBack Power: GS4048A {240V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 3,600 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 56 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 44 V - 56 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 80.1444 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 93.58% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2020-12-01 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for OutBack Power: GS4048A {240V}?
Evaluates OutBack Power: GS4048A {240V} (20 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 20 A | PASS (120% Rule) |
| 150A Bus / 150A Main | 30 A | 20 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 20 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 20 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 20 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With OutBack Power: GS4048A {240V}?
Sample PV string lengths aligned within 44-56 V MPPT and 56 V DC max at -10 C. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 | 515.0 W | 53.76 V | 1 panel (micro/module) | 0.52 kW |
Which Competing Grid-Support Inverters Compare to OutBack Power: GS4048A {240V}?
Competing CEC grid-support inverters near 3,600 W AC and 240 V, led by ABB: PVI-36-OUTD-S-US-A {240V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| ABB: PVI-36-OUTD-S-US-A {240V} ABB |
3,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.26% |
| ABB: PVI-36-OUTD-S-US-Z-A {240V} ABB |
3,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.26% |
| ABB: PVI-36-OUTD-S-US-Z-M-A {240V} ABB |
3,600 W | Tie (0 W) | 240.0 V | 480.0 V | 96.26% |
| Altenergy Power System Inc: ELS-3K {240V} Altenergy Power System Inc |
3,685 W | +85 W | 240.0 V | 60.0 V | 94.4% |
What Are the Interconnection Limits and Best-Fit Uses for OutBack Power: GS4048A {240V}?
Check OutBack Power: GS4048A {240V} (3,600 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 56 V DC on OutBack Power: GS4048A {240V}.
OutBack Power: GS4048A {240V} Panel & Wire Spec
Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (15.0 A continuous).
Alternative Inverter Comparison
Compare efficiency (93.58%) and MPPT window (44-56 V) directly against ABB: PVI-36-OUTD-S-US-A {240V} (3,600 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for OutBack Power: GS4048A {240V} by OutBack Power covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does OutBack Power: GS4048A {240V} require?
At 3,600 W continuous AC (240 V), continuous current is 15.0 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.
Does OutBack Power: GS4048A {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 20 A at 240 V means PASS (120% Rule).
How does OutBack Power: GS4048A {240V} compare to ABB: PVI-36-OUTD-S-US-A {240V}?
OutBack Power: GS4048A {240V} delivers 3,600 W AC at 93.58% CEC efficiency with a 56 V DC ceiling, while ABB: PVI-36-OUTD-S-US-A {240V} outputs 3,600 W at 240 V.