ABB: PVI-36-OUTD-S-US-A {240V} outputs 3,600 W AC at 240 V (15.0 A continuous, 20 A OCPD), ranking #1,808 of 2,343 CEC inverters at 96.26% efficiency with a 100-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 3,600 W
- AC Voltage
- 240 V
- Min PV Breaker
- 20 A (12 AWG Cu)
- CEC Efficiency
- 96.26%
How Does ABB: PVI-36-OUTD-S-US-A {240V} Compare Against Peer CEC Listings?
NEC 705.12 breaker requirements, efficiency placement, and 240 V grid-support overview for ABB: PVI-36-OUTD-S-US-A {240V}. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
Rated at 3,600 W AC (15.0 A continuous), ABB: PVI-36-OUTD-S-US-A {240V} ranks #1,808 of 2,343 CEC units at 96.26% efficiency (-0.42 pts vs the 96.68% 240 V median). Minimum 75 C copper conductor sizing for its 20 A circuit is 12 AWG Cu per NEC Table 310.16. Cold-weather string Voc must remain under 480 V DC at record local winter lows.
Where Does ABB: PVI-36-OUTD-S-US-A {240V} Fall Across Listed CEC Models?
Marks ABB: PVI-36-OUTD-S-US-A {240V} (3,600 W AC) across the California Energy Commission inverter AC capacity distribution. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Dataset Percentiles Define ABB: PVI-36-OUTD-S-US-A {240V}?
Benchmarks ABB: PVI-36-OUTD-S-US-A {240V} continuous AC output, 96.26% CEC weighted efficiency, and 20 A OCPD breaker demand. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for ABB: PVI-36-OUTD-S-US-A {240V}?
Four key NEC 705.12 and California Energy Commission metrics defining ABB: PVI-36-OUTD-S-US-A {240V} by ABB. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
96.26% CEC Weighted Efficiency
-0.42 pts vs the 96.68% 240 V median; overall power rank #1,685 (3,600 W, below CEC median; higher than 27.6% of peers).
20 A Required Backfeed OCPD
125% x 15.0 A = 18.8 A -> 20 A standard OCPD using 12 AWG Cu (75 C).
100 V - 480 V (Max 480 V DC)
Tracking span of 380.0 V; listed since 2018-10-15 (grid-tied PV inverter).
PASS (120% Rule)
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 3600.0W / 240 V -> 15.0 A | Breaker >= 1.25 * 15.0 = 18.8 A -> 20 A
CEC Inverters.csv for ABB: PVI-36-OUTD-S-US-A {240V}: Paco=3600.0 W, Vac=240 V, Vdcmax=480.0 V, Eff=96.26%.
Result: Min 20 A breaker & 12 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).
What Are the Published CEC Specifications for ABB: PVI-36-OUTD-S-US-A {240V}?
Official laboratory CEC ratings, MPPT operating window, and DC voltage bounds recorded for ABB: PVI-36-OUTD-S-US-A {240V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 3,600 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 480 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 100 V - 480 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 10.9993 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.26% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2018-10-15 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for ABB: PVI-36-OUTD-S-US-A {240V}?
Evaluates ABB: PVI-36-OUTD-S-US-A {240V} (20 A OCPD) across standard 100 A to 225 A busbars or commercial switchboards.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 20 A | PASS (120% Rule) |
| 150A Bus / 150A Main | 30 A | 20 A | PASS (120% Rule) |
| 200A Bus / 200A Main | 40 A | 20 A | PASS (120% Rule) |
| 200A Bus / 175A Main | 65 A | 20 A | PASS (120% Rule) |
| 225A Bus / 200A Main | 70 A | 20 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With ABB: PVI-36-OUTD-S-US-A {240V}?
Sample PV string lengths aligned within 100-480 V MPPT and 480 V DC max at -10 C. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 3 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 3 to 11 panels | 4.84 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 3 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 4 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to ABB: PVI-36-OUTD-S-US-A {240V}?
Competing CEC grid-support inverters near 3,600 W AC and 240 V, led by Altenergy Power System Inc: ELS-3K {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Altenergy Power System Inc: ELS-3K {240V} Altenergy Power System Inc |
3,685 W | +85 W | 240.0 V | 60.0 V | 94.4% |
| Delta Electronics: SOLIVIA 38 NA G4 TL {240V} Delta Electronics |
3,810 W | +210 W | 240.0 V | 500.0 V | 97.6% |
| Delta Electronics: M4-TL-US {240V} Delta Electronics |
3,840 W | +240 W | 240.0 V | 480.0 V | 97.59% |
| Delta Electronics: E4-TL-US {240V} Delta Electronics |
3,870 W | +270 W | 240.0 V | 400.0 V | 97.99% |
What Are the Interconnection Limits and Best-Fit Uses for ABB: PVI-36-OUTD-S-US-A {240V}?
Check ABB: PVI-36-OUTD-S-US-A {240V} (3,600 W AC, 20 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 20 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on ABB: PVI-36-OUTD-S-US-A {240V}.
ABB: PVI-36-OUTD-S-US-A {240V} Panel & Wire Spec
Size 75 C copper conductors at 12 AWG Cu on a 20 A OCPD breaker (15.0 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.26%) and MPPT window (100-480 V) directly against Altenergy Power System Inc: ELS-3K {240V} (3,685 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for ABB: PVI-36-OUTD-S-US-A {240V} by ABB covering breaker sizing, MPPT limits, and 240 V interconnection. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What breaker and wire size does ABB: PVI-36-OUTD-S-US-A {240V} require?
At 3,600 W continuous AC (240 V), continuous current is 15.0 A; 125% NEC 690.8/705.12 sizing requires a 20 A breaker and 12 AWG Cu (75 C) wire.
Does ABB: PVI-36-OUTD-S-US-A {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 20 A at 240 V means PASS (120% Rule).
How does ABB: PVI-36-OUTD-S-US-A {240V} compare to Altenergy Power System Inc: ELS-3K {240V}?
ABB: PVI-36-OUTD-S-US-A {240V} delivers 3,600 W AC at 96.26% CEC efficiency with a 480 V DC ceiling, while Altenergy Power System Inc: ELS-3K {240V} outputs 3,685 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)