Northern Electric & Power Co Ltd: BDM-1200-LV {120V} outputs 1,194 W AC at 120 V (9.9 A continuous, 15 A OCPD), ranking #1,825 of 2,343 CEC inverters at 96.23% efficiency with a 22-55 V MPPT window and 55 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 1,194 W
- AC Voltage
- 120 V
- Min PV Breaker
- 15 A (14 AWG Cu)
- CEC Efficiency
- 96.23%
How Does Northern Electric & Power Co Ltd: BDM-1200-LV {120V} Compare Against Peer CEC Listings?
CEC efficiency rank (#1,825), 22-55 V MPPT tracking, and panel fit for Northern Electric & Power Co Ltd: BDM-1200-LV {120V}.
Northern Electric & Power Co Ltd: BDM-1200-LV {120V} from Northern Electric & Power Co Ltd outputs 9.9 A continuous AC at 120 V (1,194 W AC, rank #1,815). Paired with 14 AWG Cu conductors and a 15 A OCPD, its 96.23% CEC efficiency compares closely with Altenergy Power System Inc: DS3-LV {120V} (915 W). Keep NEC 690.7 winter string Voc below 55 V DC.
Where Does Northern Electric & Power Co Ltd: BDM-1200-LV {120V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Northern Electric & Power Co Ltd: BDM-1200-LV {120V} at 1,194 W continuous AC output.
What Dataset Percentiles Define Northern Electric & Power Co Ltd: BDM-1200-LV {120V}?
Dataset percentiles comparing Northern Electric & Power Co Ltd: BDM-1200-LV {120V} against 2,343 certified grid-support inverters nationwide. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for Northern Electric & Power Co Ltd: BDM-1200-LV {120V}?
Engineering highlights for Northern Electric & Power Co Ltd: BDM-1200-LV {120V} covering efficiency, 14 AWG Cu feeder, and panel compatibility.
96.23% CEC Weighted Efficiency
+1.50 pts vs the 94.73% 120 V median; overall power rank #1,815 (1,194 W, below CEC median; higher than 22.5% of peers).
15 A Required Backfeed OCPD
125% x 9.9 A = 12.4 A -> 15 A standard OCPD using 14 AWG Cu (75 C).
22 V - 55 V (Max 55 V DC)
Tracking span of 33.0 V; listed since 2025-11-12 (grid-tied PV inverter).
120V AC Coupled / Dedicated Transformer
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 1193.5W / 120 V -> 9.9 A | Breaker >= 1.25 * 9.9 = 12.4 A -> 15 A
CEC Inverters.csv for Northern Electric & Power Co Ltd: BDM-1200-LV {120V}: Paco=1193.5 W, Vac=120 V, Vdcmax=55.0 V, Eff=96.23%.
Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: 120V AC Coupled / Dedicated Transformer.
What Are the Published CEC Specifications for Northern Electric & Power Co Ltd: BDM-1200-LV {120V}?
California Energy Commission Solar Equipment List parameters for Northern Electric & Power Co Ltd: BDM-1200-LV {120V} (grid-tied PV inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 1,194 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 120 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 55 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 22 V - 55 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 35.436 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 96.23% | Calculated AC/DC conversion ratio from CEC test protocol |
| CEC Listing Date & Hybrid | 2025-11-12 / Hybrid: No (Grid-Tied PV) | Utility interconnection approval metadata |
Can a Residential Panel Meet 120% Busbar Limits for Northern Electric & Power Co Ltd: BDM-1200-LV {120V}?
Panelboard and switchgear backfeed allowances for Northern Electric & Power Co Ltd: BDM-1200-LV {120V} (15 A OCPD). Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 15 A | 120V AC Coupled / Dedicated Transformer |
| 150A Bus / 150A Main | 30 A | 15 A | 120V AC Coupled / Dedicated Transformer |
| 200A Bus / 200A Main | 40 A | 15 A | 120V AC Coupled / Dedicated Transformer |
| 200A Bus / 175A Main | 65 A | 15 A | 120V AC Coupled / Dedicated Transformer |
| 225A Bus / 200A Main | 70 A | 15 A | 120V AC Coupled / Dedicated Transformer |
Which CEC PV Module Strings Pair With Northern Electric & Power Co Ltd: BDM-1200-LV {120V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Northern Electric & Power Co Ltd: BDM-1200-LV {120V}.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 1 panel (micro/module) | 0.44 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 1 panel (micro/module) | 0.42 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 1 panel (micro/module) | 0.2 kW |
| Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 | 515.0 W | 53.76 V | 1 panel (micro/module) | 0.52 kW |
Which Competing Grid-Support Inverters Compare to Northern Electric & Power Co Ltd: BDM-1200-LV {120V}?
Four alternative CEC inverters matched to Northern Electric & Power Co Ltd: BDM-1200-LV {120V} (1,194 W AC), led by Altenergy Power System Inc: DS3-LV {120V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Altenergy Power System Inc: DS3-LV {120V} Altenergy Power System Inc |
915 W | -278 W | 120.0 V | 45.0 V | 94.08% |
| Altenergy Power System Inc: EZ1-LV {120V} Altenergy Power System Inc |
915 W | -278 W | 120.0 V | 45.0 V | 94.08% |
| Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} Apparent Inc |
326 W | -868 W | 120.0 V | 52.0 V | 90.97% |
| Apparent Inc: SG424U CA 120VAC 60Hz {120V} Apparent Inc |
250 W | -944 W | 120.0 V | 48.9 V | 91.11% |
What Are the Interconnection Limits and Best-Fit Uses for Northern Electric & Power Co Ltd: BDM-1200-LV {120V}?
Check Northern Electric & Power Co Ltd: BDM-1200-LV {120V} (1,194 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Requires a 15 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 55 V DC on Northern Electric & Power Co Ltd: BDM-1200-LV {120V}.
Northern Electric & Power Co Ltd: BDM-1200-LV {120V} Panel & Wire Spec
Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (9.9 A continuous).
Alternative Inverter Comparison
Compare efficiency (96.23%) and MPPT window (22-55 V) directly against Altenergy Power System Inc: DS3-LV {120V} (915 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Northern Electric & Power Co Ltd: BDM-1200-LV {120V} by Northern Electric & Power Co Ltd covering breaker sizing, MPPT limits, and 120 V interconnection.
What breaker and wire size does Northern Electric & Power Co Ltd: BDM-1200-LV {120V} require?
At 1,194 W continuous AC (120 V), continuous current is 9.9 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.
Does Northern Electric & Power Co Ltd: BDM-1200-LV {120V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 120 V means 120V AC Coupled / Dedicated Transformer.
How does Northern Electric & Power Co Ltd: BDM-1200-LV {120V} compare to Altenergy Power System Inc: DS3-LV {120V}?
Northern Electric & Power Co Ltd: BDM-1200-LV {120V} delivers 1,194 W AC at 96.23% CEC efficiency with a 55 V DC ceiling, while Altenergy Power System Inc: DS3-LV {120V} outputs 915 W at 120 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)