Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} — CEC Inverter Specifications

Manufacturer: Apparent Inc Registry: CEC Verified Engineering Specification

Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} outputs 326 W AC at 120 V (2.7 A continuous, 15 A OCPD), ranking #2,338 of 2,343 CEC inverters at 90.97% efficiency with a 36-52 V MPPT window and 52 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
326 W
AC Voltage
120 V
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
90.97%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} Compare Against Peer CEC Listings?

Breaker sizing (15 A), 14 AWG Cu wire rules, and DC input limits for Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V}.

For NEC 705.12 solar interconnection, Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} outputs 2.7 A continuous AC at 120 V and needs a 15 A backfeed breaker on 14 AWG Cu (75 C). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit. Conversion efficiency scores 90.97% (#2,338 of 2,343, -5.85 pts vs overall CEC median).

Where Does Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} Fall Across Listed CEC Models?

Output power comparison showing where Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} sits among all 2,343 CEC-listed grid-support inverters. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} (326 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACApparent Inc: SG42: 326 W

What Dataset Percentiles Define Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V}?

Relative ranking of Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} Technical ThresholdsPercentile comparison for Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output326 WCEC Efficiency90.97%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V}?

Snapshot of Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} efficiency rank (#2,338), OCPD breaker size, MPPT span, and busbar verdict. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Eff #2,338 / 2,343

90.97% CEC Weighted Efficiency

-3.76 pts vs the 94.73% 120 V median; overall power rank #2,131 (326 W, below CEC median; higher than 9.0% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 2.7 A = 3.4 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

36 V - 52 V (Max 52 V DC)

Tracking span of 16.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

120V AC Coupled / Dedicated Transformer

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 326.0W / 120 V -> 2.7 A | Breaker >= 1.25 * 2.7 = 3.4 A -> 15 A

CEC Inverters.csv for Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V}: Paco=326.0 W, Vac=120 V, Vdcmax=52.0 V, Eff=90.97%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: 120V AC Coupled / Dedicated Transformer.

What Are the Published CEC Specifications for Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Official California Energy Commission (NREL SAM) test parameters for Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 326 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 120 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 52 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 36 V - 52 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 8.14463 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 90.97% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V}?

NEC 705.12(B)(3)(2) backfeed compliance table for Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} at 120 V. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Evaluates Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} (15 A required OCPD at 120 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 15 A 120V AC Coupled / Dedicated Transformer
150A Bus / 150A Main 30 A 15 A 120V AC Coupled / Dedicated Transformer
200A Bus / 200A Main 40 A 15 A 120V AC Coupled / Dedicated Transformer
200A Bus / 175A Main 65 A 15 A 120V AC Coupled / Dedicated Transformer
225A Bus / 200A Main 70 A 15 A 120V AC Coupled / Dedicated Transformer

Which CEC PV Module Strings Pair With Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V}?

Minimum and maximum series solar module strings fitting Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} MPPT and 52 V limits. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sampled CEC PV modules aligned within 36.0-52.0 V MPPT and 52.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-0-270TW 270.0 W 42.56 V 1 panel (micro/module) 0.27 kW

Which Competing Grid-Support Inverters Compare to Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V}?

Peer 120 V CEC inverters near 326 W AC output such as Altenergy Power System Inc: DS3-LV {120V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Altenergy Power System Inc: DS3-LV {120V}
Altenergy Power System Inc
915 W +589 W 120.0 V 45.0 V 94.08%
Altenergy Power System Inc: EZ1-LV {120V}
Altenergy Power System Inc
915 W +589 W 120.0 V 45.0 V 94.08%
Northern Electric & Power Co Ltd: BDM-1200-LV {120V}
Northern Electric & Power Co Ltd
1,194 W +868 W 120.0 V 55.0 V 96.23%
Northern Electric & Power Co Ltd: BDM-1600-LV {120V}
Northern Electric & Power Co Ltd
1,597 W +1271 W 120.0 V 55.0 V 96.31%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V}?

Check Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} (326 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 52 V DC on Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V}.

Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (2.7 A continuous).

Alternative Inverter Comparison

Compare efficiency (90.97%) and MPPT window (36-52 V) directly against Altenergy Power System Inc: DS3-LV {120V} (915 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} by Apparent Inc covering breaker sizing, MPPT limits, and 120 V interconnection.

What breaker and wire size does Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} require?

At 326 W continuous AC (120 V), continuous current is 2.7 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

Does Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 120 V means 120V AC Coupled / Dedicated Transformer.

How does Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} compare to Altenergy Power System Inc: DS3-LV {120V}?

Apparent Inc: SG424-PLUS-120VAC-60HZ-CA {120V} delivers 326 W AC at 90.97% CEC efficiency with a 52 V DC ceiling, while Altenergy Power System Inc: DS3-LV {120V} outputs 915 W at 120 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.