OutBack Power: FXR3048A {120V} — CEC Inverter Specifications

Manufacturer: OutBack Power Registry: CEC Verified Engineering Specification

OutBack Power: FXR3048A {120V} outputs 2,560 W AC at 120 V (21.3 A continuous, 30 A OCPD), ranking #2,336 of 2,343 CEC inverters at 91.11% efficiency with a 40-60 V MPPT window and 60 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
2,560 W
AC Voltage
120 V
Min PV Breaker
30 A (10 AWG Cu)
CEC Efficiency
91.11%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does OutBack Power: FXR3048A {120V} Compare Against Peer CEC Listings?

Breaker sizing (30 A), 10 AWG Cu wire rules, and DC input limits for OutBack Power: FXR3048A {120V}.

Classified as a grid-tied PV inverter (listed since 2018-10-15), OutBack Power: FXR3048A {120V} requires 26.6 A design capacity -> 30 A breaker using 10 AWG Cu copper at 75 C terminals. Weighted efficiency sits at 91.11% (-5.71 pts vs overall CEC median) across 2,343 CEC models, while requires a 30 a breaker, passing directly inside a standard 200 a main / 200 a busbar panel (40 a limit).

Where Does OutBack Power: FXR3048A {120V} Fall Across Listed CEC Models?

Output power comparison showing where OutBack Power: FXR3048A {120V} sits among all 2,343 CEC-listed grid-support inverters. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where OutBack Power: FXR3048A {120V} (2,560 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACOutBack Power: FXR: 2,560 W

What Dataset Percentiles Define OutBack Power: FXR3048A {120V}?

Relative ranking of OutBack Power: FXR3048A {120V} on continuous AC power, CEC weighted efficiency, and OCPD breaker current.

OutBack Power: FXR3048A {120V} Technical ThresholdsPercentile comparison for OutBack Power: FXR3048A {120V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output2,560 WCEC Efficiency91.11%Backfeed Breaker30 A

What Do the Dataset Ranks Show for OutBack Power: FXR3048A {120V}?

Snapshot of OutBack Power: FXR3048A {120V} efficiency rank (#2,336), OCPD breaker size, MPPT span, and busbar verdict. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Eff #2,336 / 2,343

91.11% CEC Weighted Efficiency

-3.62 pts vs the 94.73% 120 V median; overall power rank #1,758 (2,560 W, below CEC median; higher than 25.0% of peers).

NEC 705.12 Check

30 A Required Backfeed OCPD

125% x 21.3 A = 26.6 A -> 30 A standard OCPD using 10 AWG Cu (75 C).

MPPT Window

40 V - 60 V (Max 60 V DC)

Tracking span of 20.0 V; listed since 2018-10-15 (grid-tied PV inverter).

Panel Fit (240V)

120V AC Coupled / Dedicated Transformer

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 2560.0W / 120 V -> 21.3 A | Breaker >= 1.25 * 21.3 = 26.6 A -> 30 A

CEC Inverters.csv for OutBack Power: FXR3048A {120V}: Paco=2560.0 W, Vac=120 V, Vdcmax=60.0 V, Eff=91.11%.

Result: Min 30 A breaker & 10 AWG Cu (75 C); 200A Bus / 200A Main: 120V AC Coupled / Dedicated Transformer.

What Are the Published CEC Specifications for OutBack Power: FXR3048A {120V}?

Complete California Energy Commission grid-support inverter ratings and hybrid battery capabilities for OutBack Power: FXR3048A {120V}. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Official California Energy Commission (NREL SAM) test parameters for OutBack Power: FXR3048A {120V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 2,560 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 120 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 60 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 40 V - 60 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 54.0342 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 91.11% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2018-10-15 / Hybrid: No (Grid-Tied PV) Utility interconnection approval metadata

Can a Residential Panel Meet 120% Busbar Limits for OutBack Power: FXR3048A {120V}?

NEC 705.12(B)(3)(2) backfeed compliance table for OutBack Power: FXR3048A {120V} at 120 V. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Evaluates OutBack Power: FXR3048A {120V} (30 A required OCPD at 120 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 30 A 120V AC Coupled / Dedicated Transformer
150A Bus / 150A Main 30 A 30 A 120V AC Coupled / Dedicated Transformer
200A Bus / 200A Main 40 A 30 A 120V AC Coupled / Dedicated Transformer
200A Bus / 175A Main 65 A 30 A 120V AC Coupled / Dedicated Transformer
225A Bus / 200A Main 70 A 30 A 120V AC Coupled / Dedicated Transformer

Which CEC PV Module Strings Pair With OutBack Power: FXR3048A {120V}?

Minimum and maximum series solar module strings fitting OutBack Power: FXR3048A {120V} MPPT and 60 V limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sampled CEC PV modules aligned within 40.0-60.0 V MPPT and 60.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 1 panel (micro/module) 0.59 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW

Which Competing Grid-Support Inverters Compare to OutBack Power: FXR3048A {120V}?

Peer 120 V CEC inverters near 2,560 W AC output such as Northern Electric & Power Co Ltd: BDM-1600-LV {120V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Northern Electric & Power Co Ltd: BDM-1600-LV {120V}
Northern Electric & Power Co Ltd
1,597 W -963 W 120.0 V 55.0 V 96.31%
Northern Electric & Power Co Ltd: BDM-1200-LV {120V}
Northern Electric & Power Co Ltd
1,194 W -1366 W 120.0 V 55.0 V 96.23%
Altenergy Power System Inc: DS3-LV {120V}
Altenergy Power System Inc
915 W -1645 W 120.0 V 45.0 V 94.08%
Altenergy Power System Inc: EZ1-LV {120V}
Altenergy Power System Inc
915 W -1645 W 120.0 V 45.0 V 94.08%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for OutBack Power: FXR3048A {120V}?

Check OutBack Power: FXR3048A {120V} (2,560 W AC, 30 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Requires a 30 A breaker, passing directly inside a standard 200 A main / 200 A busbar panel (40 A limit).
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 60 V DC on OutBack Power: FXR3048A {120V}.

OutBack Power: FXR3048A {120V} Panel & Wire Spec

Size 75 C copper conductors at 10 AWG Cu on a 30 A OCPD breaker (21.3 A continuous).

Alternative Inverter Comparison

Compare efficiency (91.11%) and MPPT window (40-60 V) directly against Northern Electric & Power Co Ltd: BDM-1600-LV {120V} (1,597 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for OutBack Power: FXR3048A {120V} by OutBack Power covering breaker sizing, MPPT limits, and 120 V interconnection.

What breaker and wire size does OutBack Power: FXR3048A {120V} require?

At 2,560 W continuous AC (120 V), continuous current is 21.3 A; 125% NEC 690.8/705.12 sizing requires a 30 A breaker and 10 AWG Cu (75 C) wire.

Does OutBack Power: FXR3048A {120V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 30 A at 120 V means 120V AC Coupled / Dedicated Transformer.

How does OutBack Power: FXR3048A {120V} compare to Northern Electric & Power Co Ltd: BDM-1600-LV {120V}?

OutBack Power: FXR3048A {120V} delivers 2,560 W AC at 91.11% CEC efficiency with a 60 V DC ceiling, while Northern Electric & Power Co Ltd: BDM-1600-LV {120V} outputs 1,597 W at 120 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.