Skip to main content
WireAndSun
Calculators
CEC PV Module

WAAREE ENERGIES LIMITED WU-140 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED WU-140 is a 140.0 W STC (124.7 W PTC) Multi-c-Si solar module ranking #21,440 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 14.24% efficiency, 21.0 V Voc at 25 C, and 23.63 V cold Voc at -10 C (25 panels max per 600 V string).

STC Wattage
140.0 W
PTC Wattage
124.7 W
Voc @ 25C
21.0 V
Efficiency
14.24%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED WU-140 Compare Against Peer CEC Listings?

Engineering position of WAAREE ENERGIES LIMITED WU-140 (140.0 W STC) vs. Auxin Solar AXN6M409T140 across 1,407 CEC Multi-c-Si solar modules.

Built with 36 Multi-c-Si cells, WAAREE ENERGIES LIMITED WU-140 pairs typical 89.1% PTC-to-STC thermal output (124.7 W real-world rating) with 21.0 V nominal Voc. An 8 kW residential build (8,120 W DC, 7,233 W PTC) saves ~$2,032/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Auxin Solar AXN6M409T140 offers a 140.0 W alternative.

Where Does WAAREE ENERGIES LIMITED WU-140 Fall Across Listed CEC Models?

Plots WAAREE ENERGIES LIMITED WU-140 at 140.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED WU-140 (140.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 140.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED WU-140?

Benchmarks WAAREE ENERGIES LIMITED WU-140 on STC wattage, thermal PTC/STC retention, and 14.24 aperture conversion efficiency against CEC peers.

WAAREE ENERGIES LIMITED WU-140 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED WU-140 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage140.0 WPTC/STC Retention89.1%Module Efficiency14.24%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WU-140?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for WAAREE ENERGIES LIMITED WU-140 by WAAREE ENERGIES LIMITED.

Rank #21,440 / 21,677

140.0 W STC · Higher Than 1.0%

140.0 W STC (-245.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,657

14.24% Aperture Efficiency

Power density 142.4 W/m2 (5.67 percentage points below 19.91% CEC median). PTC/STC ratio: 89.1% (rank #20,440).

NEC 690.7 Limit

25 Panels Max @ -10 C (600 V)

Cold Voc reaches 23.63 V at -10 C (590.8 V string) and 24.38 V at -20 C (24 max).

8 kW Reference Array

58 Panels = 8,120 W STC

Occupies 57.0 m2 (614 sq ft) producing 7,233 W PTC; NEC 690.8 OCPD floor is 14.51 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 21.0 * (1 + (-0.358/100) * (-10 - 25)) = 23.63 V | OCPD = 1.56 * 9.3 = 14.51 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WU-140: Voc=21.0 V, beta_Voc=-0.358%/C, Isc=9.3 A, STC=140.0 W, Area=0.983 m2.

Result: 25 panels max on 600 V (590.8 V); 58 panels for 8 kW (614 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WU-140?

Laboratory test ratings recorded for WAAREE ENERGIES LIMITED WU-140 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WU-140.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 140.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 124.7 W (89.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 21.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.3 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 17.0 V / 8.3 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.358 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.24% (0.983 m2) Array roof footprint density
Cell Count & Technology 36 cells (Multi-c-Si) Monofacial backsheet

How Many WAAREE ENERGIES LIMITED WU-140 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (614 sq ft at 8 kW), and estimated Year-1 electric bill offset for WAAREE ENERGIES LIMITED WU-140.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 43 6.02 kW 455 sq ft $1,507 $2,548
8 kW Class 58 8.12 kW 614 sq ft $2,032 $3,437
10 kW Class 72 10.08 kW 762 sq ft $2,523 $4,266

How Many WAAREE ENERGIES LIMITED WU-140 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for WAAREE ENERGIES LIMITED WU-140 (beta_Voc -0.358%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=21.0V and beta_Voc=-0.358%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 24.38 V 24 panels 585.1 V 41 panels
-10 C (14 F) 23.63 V 25 panels 590.8 V 42 panels
0 C (32 F) 22.88 V 26 panels 594.9 V 43 panels
25 C (77 F STC) 21.0 V 28 panels 588.0 V 47 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WU-140?

Closest cross-brand CEC competitors to WAAREE ENERGIES LIMITED WU-140 matched near 140.0 W STC and 21.0 V Voc, led by Auxin Solar AXN6M409T140.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M409T140
Auxin Solar
140.0 W Tie (0 W) 22.03 V 14.29% 89.3%
Centrosolar America DP36 140
Centrosolar America
140.0 W Tie (0 W) 22.15 V 13.85% 88.4%
Solartech Energy ASC-6P-36-140
Solartech Energy
140.0 W Tie (0 W) 22.15 V 13.85% 88.4%
US Solar USS-QCMI2-36-140
US Solar
140.0 W Tie (0 W) 22.15 V 13.85% 88.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WU-140?

Evaluate WAAREE ENERGIES LIMITED WU-140 (140.0 W STC, 21.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WU-140 reaches 24.38 V per panel—exceeding 24 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 58 panels for an 8 kW build require 614 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 58 panels (614 sq ft).
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WU-140 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED WU-140 8 kW Residential Fit

Needs 58 modules (614 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 25 panels (-10 C) or 24 panels (-20 C), or compare Auxin Solar AXN6M409T140.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 124.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WU-140 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for WAAREE ENERGIES LIMITED WU-140?

Multiplying WAAREE ENERGIES LIMITED WU-140's 9.3 A short-circuit current by 1.56 equals 14.51 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can WAAREE ENERGIES LIMITED WU-140 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 23.63 V cold Voc at 14 F and handles 9.3 A Isc; string inverters cap WAAREE ENERGIES LIMITED WU-140 at 25 panels on 600 V.

Is WAAREE ENERGIES LIMITED WU-140 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of WAAREE ENERGIES LIMITED WU-140 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.