WAAREE ENERGIES LIMITED WU-130 is a 130.0 W STC (115.5 W PTC) Multi-c-Si solar module ranking #21,472 of 21,677 CEC listings (below all-CEC median; higher than 0.9% of peers). It delivers 13.22% efficiency, 21.0 V Voc at 25 C, and 23.63 V cold Voc at -10 C (25 panels max per 600 V string).
- STC Wattage
- 130.0 W
- PTC Wattage
- 115.5 W
- Voc @ 25C
- 21.0 V
- Efficiency
- 13.22%
How Does WAAREE ENERGIES LIMITED WU-130 Compare Against Peer CEC Listings?
Solar engineering breakdown for WAAREE ENERGIES LIMITED WU-130: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 130.0 W STC and 115.5 W PTC, WAAREE ENERGIES LIMITED WU-130 sits -255.0 W vs all-CEC median (below all-CEC median; higher than 0.9% of peers) among 21,677 listed modules. Power density reaches 132.2 W/m2 (6.69 percentage points below 19.91% CEC median). Lower 21.0 V string voltage fits 25 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 42 panels in series. Alternative peer Mitsubishi Electric PV-EE130MF5F rates 130.0 W.
Where Does WAAREE ENERGIES LIMITED WU-130 Fall Across Listed CEC Models?
Distribution marker showing WAAREE ENERGIES LIMITED WU-130 (130.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define WAAREE ENERGIES LIMITED WU-130?
Dataset percentiles tracking WAAREE ENERGIES LIMITED WU-130 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WU-130?
Benchmark highlights for WAAREE ENERGIES LIMITED WU-130 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
130.0 W STC · Higher Than 0.9%
130.0 W STC (-255.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.22% Aperture Efficiency
Power density 132.2 W/m2 (6.69 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).
25 Panels Max @ -10 C (600 V)
Cold Voc reaches 23.63 V at -10 C (590.8 V string) and 24.38 V at -20 C (24 max).
62 Panels = 8,060 W STC
Occupies 60.9 m2 (656 sq ft) producing 7,161 W PTC; NEC 690.8 OCPD floor is 13.42 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 21.0 * (1 + (-0.358/100) * (-10 - 25)) = 23.63 V | OCPD = 1.56 * 8.6 = 13.42 A
Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WU-130: Voc=21.0 V, beta_Voc=-0.358%/C, Isc=8.6 A, STC=130.0 W, Area=0.983 m2.
Result: 25 panels max on 600 V (590.8 V); 62 panels for 8 kW (656 sq ft).
What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WU-130?
Official CEC datasheet figures for WAAREE ENERGIES LIMITED WU-130 (Multi-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 130.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 115.5 W (88.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 21.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 17.0 V / 7.7 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.358 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.22% (0.983 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many WAAREE ENERGIES LIMITED WU-130 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many WAAREE ENERGIES LIMITED WU-130 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 47 | 6.11 kW | 497 sq ft | $1,529 | $2,586 |
| 8 kW Class | 62 | 8.06 kW | 656 sq ft | $2,017 | $3,411 |
| 10 kW Class | 77 | 10.01 kW | 815 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?
Consolidated WAAREE ENERGIES LIMITED wattage variants sharing the WAAREE ENERGIES LIMITED WU-130 mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| WAAREE ENERGIES LIMITED WU-125 | 125.0 W | 111.0 W | 21.0 V | 17.0 V | 12.71% |
| WAAREE ENERGIES LIMITED WU-130 | 130.0 W | 115.5 W | 21.0 V | 17.0 V | 13.22% |
How Many WAAREE ENERGIES LIMITED WU-130 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED WU-130 (23.63 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 24.38 V | 24 panels | 585.1 V | 41 panels |
| -10 C (14 F) | 23.63 V | 25 panels | 590.8 V | 42 panels |
| 0 C (32 F) | 22.88 V | 26 panels | 594.9 V | 43 panels |
| 25 C (77 F STC) | 21.0 V | 28 panels | 588.0 V | 47 panels |
Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WU-130?
Competing CEC solar panels closest to WAAREE ENERGIES LIMITED WU-130 in nameplate wattage and Voc, starting with Mitsubishi Electric PV-EE130MF5F.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Mitsubishi Electric PV-EE130MF5F Mitsubishi Electric |
130.0 W | Tie (0 W) | 21.9 V | 12.9% | 90.0% |
| Gintung Energy ASEC-135G6M Gintung Energy |
135.0 W | +5.0 W | 22.1 V | 13.74% | 89.3% |
| United Renewable Energy Co Ltd D6P135A1F United Renewable Energy Co Ltd |
135.0 W | +5.0 W | 22.1 V | 13.74% | 89.3% |
| Gintung Energy ASEC-135G6S Gintung Energy |
135.0 W | +5.0 W | 22.15 V | 13.74% | 89.6% |
What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WU-130?
Evaluate WAAREE ENERGIES LIMITED WU-130 (130.0 W STC, 21.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WU-130 reaches 24.38 V per panel—exceeding 24 panels in series voids 600 V inverter warranties.
- Footprint constraint: 62 panels for an 8 kW build require 656 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 62 panels (656 sq ft).
- 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WU-130 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
WAAREE ENERGIES LIMITED WU-130 8 kW Residential Fit
Needs 62 modules (656 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 25 panels (-10 C) or 24 panels (-20 C), or compare Mitsubishi Electric PV-EE130MF5F.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 115.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for WAAREE ENERGIES LIMITED WU-130 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.
How many WAAREE ENERGIES LIMITED WU-130 panels fit on a 600 V winter solar string?
At -10 C (14 F), WAAREE ENERGIES LIMITED WU-130 cold Voc rises from 21.0 V to 23.63 V (beta_Voc -0.358%/C), capping a 600 V string at 25 panels (590.8 V).
How much roof area does an 8 kW array of WAAREE ENERGIES LIMITED WU-130 need?
An 8 kW DC system uses 62 WAAREE ENERGIES LIMITED WU-130 modules (8,060 W STC / 7,161 W PTC), covering roughly 656 sq ft and saving ~$2,017/yr at 18.54 c/kWh.
How does WAAREE ENERGIES LIMITED WU-130 compare against Mitsubishi Electric PV-EE130MF5F?
WAAREE ENERGIES LIMITED WU-130 outputs 130.0 W STC (21.0 V Voc, rank #21,472 of 21,677), while Mitsubishi Electric PV-EE130MF5F delivers 130.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)