Skip to main content
WireAndSun
Calculators
CEC PV Module

WAAREE ENERGIES LIMITED WU-130 — CEC Solar Module Specifications

Manufacturer: WAAREE ENERGIES LIMITED Registry: CEC Verified Engineering Specification

WAAREE ENERGIES LIMITED WU-130 is a 130.0 W STC (115.5 W PTC) Multi-c-Si solar module ranking #21,472 of 21,677 CEC listings (below all-CEC median; higher than 0.9% of peers). It delivers 13.22% efficiency, 21.0 V Voc at 25 C, and 23.63 V cold Voc at -10 C (25 panels max per 600 V string).

STC Wattage
130.0 W
PTC Wattage
115.5 W
Voc @ 25C
21.0 V
Efficiency
13.22%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does WAAREE ENERGIES LIMITED WU-130 Compare Against Peer CEC Listings?

Solar engineering breakdown for WAAREE ENERGIES LIMITED WU-130: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 130.0 W STC and 115.5 W PTC, WAAREE ENERGIES LIMITED WU-130 sits -255.0 W vs all-CEC median (below all-CEC median; higher than 0.9% of peers) among 21,677 listed modules. Power density reaches 132.2 W/m2 (6.69 percentage points below 19.91% CEC median). Lower 21.0 V string voltage fits 25 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 42 panels in series. Alternative peer Mitsubishi Electric PV-EE130MF5F rates 130.0 W.

Where Does WAAREE ENERGIES LIMITED WU-130 Fall Across Listed CEC Models?

Distribution marker showing WAAREE ENERGIES LIMITED WU-130 (130.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where WAAREE ENERGIES LIMITED WU-130 (130.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCWAAREE ENERGIES LI: 130.0 W

What Dataset Percentiles Define WAAREE ENERGIES LIMITED WU-130?

Dataset percentiles tracking WAAREE ENERGIES LIMITED WU-130 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

WAAREE ENERGIES LIMITED WU-130 Engineering BenchmarksPercentile comparison of WAAREE ENERGIES LIMITED WU-130 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage130.0 WPTC/STC Retention88.8%Module Efficiency13.22%

What Do the Dataset Ranks Show for WAAREE ENERGIES LIMITED WU-130?

Benchmark highlights for WAAREE ENERGIES LIMITED WU-130 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,472 / 21,677

130.0 W STC · Higher Than 0.9%

130.0 W STC (-255.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,345

13.22% Aperture Efficiency

Power density 132.2 W/m2 (6.69 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

25 Panels Max @ -10 C (600 V)

Cold Voc reaches 23.63 V at -10 C (590.8 V string) and 24.38 V at -20 C (24 max).

8 kW Reference Array

62 Panels = 8,060 W STC

Occupies 60.9 m2 (656 sq ft) producing 7,161 W PTC; NEC 690.8 OCPD floor is 13.42 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 21.0 * (1 + (-0.358/100) * (-10 - 25)) = 23.63 V | OCPD = 1.56 * 8.6 = 13.42 A

Inputs from CEC Modules.csv for WAAREE ENERGIES LIMITED WU-130: Voc=21.0 V, beta_Voc=-0.358%/C, Isc=8.6 A, STC=130.0 W, Area=0.983 m2.

Result: 25 panels max on 600 V (590.8 V); 62 panels for 8 kW (656 sq ft).

What Are the Published CEC Specifications for WAAREE ENERGIES LIMITED WU-130?

Official CEC datasheet figures for WAAREE ENERGIES LIMITED WU-130 (Multi-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for WAAREE ENERGIES LIMITED WU-130.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 130.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 115.5 W (88.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 21.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.6 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 17.0 V / 7.7 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.358 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.22% (0.983 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many WAAREE ENERGIES LIMITED WU-130 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many WAAREE ENERGIES LIMITED WU-130 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 47 6.11 kW 497 sq ft $1,529 $2,586
8 kW Class 62 8.06 kW 656 sq ft $2,017 $3,411
10 kW Class 77 10.01 kW 815 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This WAAREE ENERGIES LIMITED Series?

Consolidated WAAREE ENERGIES LIMITED wattage variants sharing the WAAREE ENERGIES LIMITED WU-130 mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the WAAREE ENERGIES LIMITED WU-130 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
WAAREE ENERGIES LIMITED WU-125 125.0 W 111.0 W 21.0 V 17.0 V 12.71%
WAAREE ENERGIES LIMITED WU-130 130.0 W 115.5 W 21.0 V 17.0 V 13.22%

How Many WAAREE ENERGIES LIMITED WU-130 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on WAAREE ENERGIES LIMITED WU-130 (23.63 V at 14 F).

Computed from Voc=21.0V and beta_Voc=-0.358%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 24.38 V 24 panels 585.1 V 41 panels
-10 C (14 F) 23.63 V 25 panels 590.8 V 42 panels
0 C (32 F) 22.88 V 26 panels 594.9 V 43 panels
25 C (77 F STC) 21.0 V 28 panels 588.0 V 47 panels

Which Cross-Brand Solar Modules Compare Closest to WAAREE ENERGIES LIMITED WU-130?

Competing CEC solar panels closest to WAAREE ENERGIES LIMITED WU-130 in nameplate wattage and Voc, starting with Mitsubishi Electric PV-EE130MF5F.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Mitsubishi Electric PV-EE130MF5F
Mitsubishi Electric
130.0 W Tie (0 W) 21.9 V 12.9% 90.0%
Gintung Energy ASEC-135G6M
Gintung Energy
135.0 W +5.0 W 22.1 V 13.74% 89.3%
United Renewable Energy Co Ltd D6P135A1F
United Renewable Energy Co Ltd
135.0 W +5.0 W 22.1 V 13.74% 89.3%
Gintung Energy ASEC-135G6S
Gintung Energy
135.0 W +5.0 W 22.15 V 13.74% 89.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for WAAREE ENERGIES LIMITED WU-130?

Evaluate WAAREE ENERGIES LIMITED WU-130 (130.0 W STC, 21.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), WAAREE ENERGIES LIMITED WU-130 reaches 24.38 V per panel—exceeding 24 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 62 panels for an 8 kW build require 656 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 62 panels (656 sq ft).
  • 2026 tax credit baseline: cash residential installs of WAAREE ENERGIES LIMITED WU-130 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

WAAREE ENERGIES LIMITED WU-130 8 kW Residential Fit

Needs 62 modules (656 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 25 panels (-10 C) or 24 panels (-20 C), or compare Mitsubishi Electric PV-EE130MF5F.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 115.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for WAAREE ENERGIES LIMITED WU-130 by WAAREE ENERGIES LIMITED grounded in CEC test data and NEC 690.7/690.8 limits.

How many WAAREE ENERGIES LIMITED WU-130 panels fit on a 600 V winter solar string?

At -10 C (14 F), WAAREE ENERGIES LIMITED WU-130 cold Voc rises from 21.0 V to 23.63 V (beta_Voc -0.358%/C), capping a 600 V string at 25 panels (590.8 V).

How much roof area does an 8 kW array of WAAREE ENERGIES LIMITED WU-130 need?

An 8 kW DC system uses 62 WAAREE ENERGIES LIMITED WU-130 modules (8,060 W STC / 7,161 W PTC), covering roughly 656 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does WAAREE ENERGIES LIMITED WU-130 compare against Mitsubishi Electric PV-EE130MF5F?

WAAREE ENERGIES LIMITED WU-130 outputs 130.0 W STC (21.0 V Voc, rank #21,472 of 21,677), while Mitsubishi Electric PV-EE130MF5F delivers 130.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.