Skip to main content
WireAndSun
Calculators
CEC PV Module

Mitsubishi Electric PV-EE130MF5F — CEC Solar Module Specifications

Manufacturer: Mitsubishi Electric Registry: CEC Verified Engineering Specification

Mitsubishi Electric PV-EE130MF5F is a 130.0 W STC (117.0 W PTC) Multi-c-Si solar module ranking #21,472 of 21,677 CEC listings (below all-CEC median; higher than 0.9% of peers). It delivers 12.9% efficiency, 21.9 V Voc at 25 C, and 24.69 V cold Voc at -10 C (24 panels max per 600 V string).

STC Wattage
130.0 W
PTC Wattage
117.0 W
Voc @ 25C
21.9 V
Efficiency
12.9%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Mitsubishi Electric PV-EE130MF5F Compare Against Peer CEC Listings?

How Mitsubishi Electric Mitsubishi Electric PV-EE130MF5F handles rooftop heat (117.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Mitsubishi Electric PV-EE130MF5F exhibits 8.05 A short-circuit current, requiring a 12.56 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,472 of 21,677 (148.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 62.5 m2 for an 8 kW system (77 panels for 10 kW). Lower 21.9 V string voltage fits 24 panels in series at 14 F and pairs easily with microinverters.

Where Does Mitsubishi Electric PV-EE130MF5F Fall Across Listed CEC Models?

Where Mitsubishi Electric PV-EE130MF5F (130.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Mitsubishi Electric PV-EE130MF5F (130.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMitsubishi Electri: 130.0 W

What Dataset Percentiles Define Mitsubishi Electric PV-EE130MF5F?

Percentile placement of Mitsubishi Electric PV-EE130MF5F across power density (129.0 W/m2), thermal retention, and nameplate STC wattage.

Mitsubishi Electric PV-EE130MF5F Engineering BenchmarksPercentile comparison of Mitsubishi Electric PV-EE130MF5F wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage130.0 WPTC/STC Retention90.0%Module Efficiency12.9%

What Do the Dataset Ranks Show for Mitsubishi Electric PV-EE130MF5F?

Four critical engineering numbers homeowners and solar installers check first when reviewing Mitsubishi Electric PV-EE130MF5F specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #21,472 / 21,677

130.0 W STC · Higher Than 0.9%

130.0 W STC (-255.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,440

12.9% Aperture Efficiency

Power density 129.0 W/m2 (7.01 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).

NEC 690.7 Limit

24 Panels Max @ -10 C (600 V)

Cold Voc reaches 24.69 V at -10 C (592.6 V string) and 25.49 V at -20 C (23 max).

8 kW Reference Array

62 Panels = 8,060 W STC

Occupies 62.5 m2 (673 sq ft) producing 7,254 W PTC; NEC 690.8 OCPD floor is 12.56 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 21.9 * (1 + (-0.364/100) * (-10 - 25)) = 24.69 V | OCPD = 1.56 * 8.05 = 12.56 A

Inputs from CEC Modules.csv for Mitsubishi Electric PV-EE130MF5F: Voc=21.9 V, beta_Voc=-0.364%/C, Isc=8.05 A, STC=130.0 W, Area=1.008 m2.

Result: 24 panels max on 600 V (592.6 V); 62 panels for 8 kW (673 sq ft).

What Are the Published CEC Specifications for Mitsubishi Electric PV-EE130MF5F?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Mitsubishi Electric PV-EE130MF5F.

Official California Energy Commission (NREL SAM) test parameters for Mitsubishi Electric PV-EE130MF5F.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 130.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 117.0 W (90.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 21.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.05 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 17.4 V / 7.47 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.364 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 12.9% (1.008 m2) Array roof footprint density
Cell Count & Technology 36 cells (Multi-c-Si) Monofacial backsheet

How Many Mitsubishi Electric PV-EE130MF5F Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Mitsubishi Electric PV-EE130MF5F (130.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 47 6.11 kW 510 sq ft $1,529 $2,586
8 kW Class 62 8.06 kW 673 sq ft $2,017 $3,411
10 kW Class 77 10.01 kW 835 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Mitsubishi Electric Series?

All closely matched Mitsubishi Electric wattages and cosmetic trims sharing the Mitsubishi Electric PV-EE130MF5F architecture. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Mitsubishi Electric PV-EE130MF5F wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Mitsubishi Electric PV-EE125MF5F 125.0 W 112.4 W 21.8 V 17.3 V 12.41%
Mitsubishi Electric PV-EE130MF5F 130.0 W 117.0 W 21.9 V 17.4 V 12.9%

How Many Mitsubishi Electric PV-EE130MF5F Modules Fit in a Cold-Weather String?

Maximum series module counts for Mitsubishi Electric PV-EE130MF5F from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=21.9V and beta_Voc=-0.364%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 25.49 V 23 panels 586.3 V 39 panels
-10 C (14 F) 24.69 V 24 panels 592.6 V 40 panels
0 C (32 F) 23.89 V 25 panels 597.2 V 41 panels
25 C (77 F STC) 21.9 V 27 panels 591.3 V 45 panels

Which Cross-Brand Solar Modules Compare Closest to Mitsubishi Electric PV-EE130MF5F?

Alternative CEC solar modules from competing brands near Mitsubishi Electric PV-EE130MF5F (130.0 W), including WAAREE ENERGIES LIMITED WU-130.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
WAAREE ENERGIES LIMITED WU-130
WAAREE ENERGIES LIMITED
130.0 W Tie (0 W) 21.0 V 13.22% 88.8%
Gintung Energy ASEC-135G6M
Gintung Energy
135.0 W +5.0 W 22.1 V 13.74% 89.3%
United Renewable Energy Co Ltd D6P135A1F
United Renewable Energy Co Ltd
135.0 W +5.0 W 22.1 V 13.74% 89.3%
Gintung Energy ASEC-135G6S
Gintung Energy
135.0 W +5.0 W 22.15 V 13.74% 89.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Mitsubishi Electric PV-EE130MF5F?

Evaluate Mitsubishi Electric PV-EE130MF5F (130.0 W STC, 21.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Mitsubishi Electric PV-EE130MF5F reaches 25.49 V per panel—exceeding 23 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 62 panels for an 8 kW build require 673 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 62 panels (673 sq ft).
  • 2026 tax credit baseline: cash residential installs of Mitsubishi Electric PV-EE130MF5F carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Mitsubishi Electric PV-EE130MF5F 8 kW Residential Fit

Needs 62 modules (673 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 24 panels (-10 C) or 23 panels (-20 C), or compare WAAREE ENERGIES LIMITED WU-130.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 117.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Mitsubishi Electric PV-EE130MF5F by Mitsubishi Electric grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Mitsubishi Electric PV-EE130MF5F PTC wattage (117.0 W) lower than STC (130.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 117.0 W PTC (90.0% retention) across Mitsubishi Electric PV-EE130MF5F's 1.008 m2 aperture.

Who should skip Mitsubishi Electric PV-EE130MF5F on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 62 Mitsubishi Electric PV-EE130MF5F panels (673 sq ft) leave unusable roof gaps vs. WAAREE ENERGIES LIMITED WU-130.

What is the 1,000 V commercial string limit for Mitsubishi Electric PV-EE130MF5F?

On 1,000 V commercial inverters at -10 C (24.69 V cold Voc), Mitsubishi Electric PV-EE130MF5F fits up to 40 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Mitsubishi Electric PV-EE130MF5F.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.