US Solar USS-QCMI3-60-235 is a 235.0 W STC (211.3 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.33% efficiency, 37.5 V Voc at 25 C, and 41.95 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 235.0 W
- PTC Wattage
- 211.3 W
- Voc @ 25C
- 37.5 V
- Efficiency
- 14.33%
How Does US Solar USS-QCMI3-60-235 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for US Solar USS-QCMI3-60-235 (Multi-c-Si) residential solar systems.
Homeowners evaluating US Solar USS-QCMI3-60-235 need 26 panels for 6 kW or 35 panels (618 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (618 sq ft). Under NEC 690.7(A), beta_Voc (-0.339%/C) pushes open-circuit voltage to 41.95 V at 14 F and 43.22 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does US Solar USS-QCMI3-60-235 Fall Across Listed CEC Models?
Comparison of US Solar USS-QCMI3-60-235 (235.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Dataset Percentiles Define US Solar USS-QCMI3-60-235?
Relative ranking of US Solar USS-QCMI3-60-235 across nameplate watts, 89.9% PTC thermal ratio, and module aperture efficiency. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Do the Dataset Ranks Show for US Solar USS-QCMI3-60-235?
Summary of US Solar USS-QCMI3-60-235 output rank, 8 kW array size (35 panels), efficiency rating, and 600 V string limit.
235.0 W STC · Higher Than 5.4%
235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.33% Aperture Efficiency
Power density 143.3 W/m2 (5.58 percentage points below 19.91% CEC median). PTC/STC ratio: 89.9% (rank #19,247).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.95 V at -10 C (587.3 V string) and 43.22 V at -20 C (13 max).
35 Panels = 8,225 W STC
Occupies 57.4 m2 (618 sq ft) producing 7,396 W PTC; NEC 690.8 OCPD floor is 13.03 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.5 * (1 + (-0.339/100) * (-10 - 25)) = 41.95 V | OCPD = 1.56 * 8.35 = 13.03 A
Inputs from CEC Modules.csv for US Solar USS-QCMI3-60-235: Voc=37.5 V, beta_Voc=-0.339%/C, Isc=8.35 A, STC=235.0 W, Area=1.64 m2.
Result: 14 panels max on 600 V (587.3 V); 35 panels for 8 kW (618 sq ft).
What Are the Published CEC Specifications for US Solar USS-QCMI3-60-235?
Complete CEC test sheet for US Solar USS-QCMI3-60-235 including Isc (8.35 A), Voc (37.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 211.3 W (89.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 29.87 V / 7.87 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.339 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.33% (1.64 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many US Solar USS-QCMI3-60-235 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using US Solar USS-QCMI3-60-235.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 26 | 6.11 kW | 459 sq ft | $1,529 | $2,586 |
| 8 kW Class | 35 | 8.22 kW | 618 sq ft | $2,057 | $3,479 |
| 10 kW Class | 43 | 10.11 kW | 759 sq ft | $2,530 | $4,279 |
Which Sibling Wattage & Trim Variants Belong to This US Solar Series?
Related US Solar power steps and black/silver trims consolidated into this US Solar USS-QCMI3-60-235 series guide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| US Solar USS-QCMI3-60-225 | 225.0 W | 202.1 W | 36.8 V | 29.26 V | 13.72% |
| US Solar USS-QCMI3-60-230 | 230.0 W | 206.7 W | 37.34 V | 29.49 V | 14.03% |
| US Solar USS-QCMI3-60-235 | 235.0 W | 211.3 W | 37.5 V | 29.87 V | 14.33% |
| US Solar USS-QCMI3-60-240 | 240.0 W | 215.9 W | 37.82 V | 30.04 V | 14.64% |
| US Solar USS-QCMI3-60-245 | 245.0 W | 220.5 W | 38.0 V | 30.19 V | 14.94% |
How Many US Solar USS-QCMI3-60-235 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for US Solar USS-QCMI3-60-235 (37.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.22 V | 13 panels | 561.9 V | 23 panels |
| -10 C (14 F) | 41.95 V | 14 panels | 587.3 V | 23 panels |
| 0 C (32 F) | 40.68 V | 14 panels | 569.5 V | 24 panels |
| 25 C (77 F STC) | 37.5 V | 16 panels | 600.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI3-60-235?
Four comparable CEC modules such as Advance Power API-M235 (235.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-M235 Advance Power |
235.0 W | Tie (0 W) | 37.5 V | 14.35% | 89.3% |
| Auxin Solar AXN6M610T235 Auxin Solar |
235.0 W | Tie (0 W) | 37.5 V | 14.35% | 89.3% |
| APOS Energy AS235 APOS Energy |
235.0 W | Tie (0 W) | 37.34 V | 14.17% | 89.7% |
| Gintech Energy GTE 235M Gintech Energy |
235.0 W | Tie (0 W) | 37.32 V | 13.97% | 89.5% |
What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI3-60-235?
Evaluate US Solar USS-QCMI3-60-235 (235.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI3-60-235 reaches 43.22 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 618 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (618 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI3-60-235 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
US Solar USS-QCMI3-60-235 8 kW Residential Fit
Needs 35 modules (618 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Advance Power API-M235.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 211.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for US Solar USS-QCMI3-60-235 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is US Solar USS-QCMI3-60-235 PTC wattage (211.3 W) lower than STC (235.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 211.3 W PTC (89.9% retention) across US Solar USS-QCMI3-60-235's 1.64 m2 aperture.
Who should skip US Solar USS-QCMI3-60-235 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 US Solar USS-QCMI3-60-235 panels (618 sq ft) leave unusable roof gaps vs. Advance Power API-M235.
What is the 1,000 V commercial string limit for US Solar USS-QCMI3-60-235?
On 1,000 V commercial inverters at -10 C (41.95 V cold Voc), US Solar USS-QCMI3-60-235 fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting US Solar USS-QCMI3-60-235.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)