US Solar USS-QCMI2-60-220 is a 220.0 W STC (197.6 W PTC) Multi-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 13.42% efficiency, 36.26 V Voc at 25 C, and 40.46 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 220.0 W
- PTC Wattage
- 197.6 W
- Voc @ 25C
- 36.26 V
- Efficiency
- 13.42%
How Does US Solar USS-QCMI2-60-220 Compare Against Peer CEC Listings?
Solar engineering breakdown for US Solar USS-QCMI2-60-220: PTC thermal retention, roof footprint, and cold Voc string bounds. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Measured at 220.0 W STC and 197.6 W PTC, US Solar USS-QCMI2-60-220 sits -165.0 W vs all-CEC median (below all-CEC median; higher than 3.8% of peers) among 21,677 listed modules. Power density reaches 134.1 W/m2 (6.49 percentage points below 19.91% CEC median). Lower 36.26 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer Centrosolar America DP60 220 rates 220.0 W.
Where Does US Solar USS-QCMI2-60-220 Fall Across Listed CEC Models?
Distribution marker showing US Solar USS-QCMI2-60-220 (220.0 W) relative to the 385.0 W all-CEC solar panel median. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Dataset Percentiles Define US Solar USS-QCMI2-60-220?
Dataset percentiles tracking US Solar USS-QCMI2-60-220 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Do the Dataset Ranks Show for US Solar USS-QCMI2-60-220?
Benchmark highlights for US Solar USS-QCMI2-60-220 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
220.0 W STC · Higher Than 3.8%
220.0 W STC (-165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.42% Aperture Efficiency
Power density 134.1 W/m2 (6.49 percentage points below 19.91% CEC median). PTC/STC ratio: 89.8% (rank #19,481).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.46 V at -10 C (566.4 V string) and 41.66 V at -20 C (14 max).
37 Panels = 8,140 W STC
Occupies 60.7 m2 (653 sq ft) producing 7,311 W PTC; NEC 690.8 OCPD floor is 13.2 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.26 * (1 + (-0.331/100) * (-10 - 25)) = 40.46 V | OCPD = 1.56 * 8.46 = 13.2 A
Inputs from CEC Modules.csv for US Solar USS-QCMI2-60-220: Voc=36.26 V, beta_Voc=-0.331%/C, Isc=8.46 A, STC=220.0 W, Area=1.64 m2.
Result: 14 panels max on 600 V (566.4 V); 37 panels for 8 kW (653 sq ft).
What Are the Published CEC Specifications for US Solar USS-QCMI2-60-220?
Official CEC datasheet figures for US Solar USS-QCMI2-60-220 (Multi-c-Si) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 220.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 197.6 W (89.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.26 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.46 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 27.64 V / 7.96 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.331 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.42% (1.64 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many US Solar USS-QCMI2-60-220 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many US Solar USS-QCMI2-60-220 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 28 | 6.16 kW | 494 sq ft | $1,542 | $2,607 |
| 8 kW Class | 37 | 8.14 kW | 653 sq ft | $2,037 | $3,445 |
| 10 kW Class | 46 | 10.12 kW | 812 sq ft | $2,533 | $4,283 |
How Many US Solar USS-QCMI2-60-220 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on US Solar USS-QCMI2-60-220 (40.46 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.66 V | 14 panels | 583.2 V | 24 panels |
| -10 C (14 F) | 40.46 V | 14 panels | 566.4 V | 24 panels |
| 0 C (32 F) | 39.26 V | 15 panels | 588.9 V | 25 panels |
| 25 C (77 F STC) | 36.26 V | 16 panels | 580.2 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI2-60-220?
Competing CEC solar panels closest to US Solar USS-QCMI2-60-220 in nameplate wattage and Voc, starting with Centrosolar America DP60 220.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP60 220 Centrosolar America |
220.0 W | Tie (0 W) | 36.26 V | 13.42% | 89.8% |
| Anhui Rinengzhongtian Semiconductor Development QJM220-60 Anhui Rinengzhongtian Semiconductor Development |
220.0 W | Tie (0 W) | 36.29 V | 13.52% | 89.8% |
| Alps Technology ATI-M660-220 Alps Technology |
220.0 W | Tie (0 W) | 36.06 V | 13.67% | 86.0% |
| Anji Technology AJP-M660-220 Anji Technology |
220.0 W | Tie (0 W) | 36.06 V | 13.55% | 86.0% |
What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI2-60-220?
Evaluate US Solar USS-QCMI2-60-220 (220.0 W STC, 36.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI2-60-220 reaches 41.66 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 37 panels for an 8 kW build require 653 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (653 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI2-60-220 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
US Solar USS-QCMI2-60-220 8 kW Residential Fit
Needs 37 modules (653 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Centrosolar America DP60 220.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 197.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for US Solar USS-QCMI2-60-220 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many US Solar USS-QCMI2-60-220 panels fit on a 600 V winter solar string?
At -10 C (14 F), US Solar USS-QCMI2-60-220 cold Voc rises from 36.26 V to 40.46 V (beta_Voc -0.331%/C), capping a 600 V string at 14 panels (566.4 V).
How much roof area does an 8 kW array of US Solar USS-QCMI2-60-220 need?
An 8 kW DC system uses 37 US Solar USS-QCMI2-60-220 modules (8,140 W STC / 7,311 W PTC), covering roughly 653 sq ft and saving ~$2,037/yr at 18.54 c/kWh.
How does US Solar USS-QCMI2-60-220 compare against Centrosolar America DP60 220?
US Solar USS-QCMI2-60-220 outputs 220.0 W STC (36.26 V Voc, rank #20,759 of 21,677), while Centrosolar America DP60 220 delivers 220.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)