Centrosolar America DP60 220 is a 220.0 W STC (197.6 W PTC) Multi-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 13.42% efficiency, 36.26 V Voc at 25 C, and 40.46 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 220.0 W
- PTC Wattage
- 197.6 W
- Voc @ 25C
- 36.26 V
- Efficiency
- 13.42%
How Does Centrosolar America DP60 220 Compare Against Peer CEC Listings?
Solar engineering breakdown for Centrosolar America DP60 220: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 220.0 W STC and 197.6 W PTC, Centrosolar America DP60 220 sits -165.0 W vs all-CEC median (below all-CEC median; higher than 3.8% of peers) among 21,677 listed modules. Power density reaches 134.1 W/m2 (6.49 percentage points below 19.91% CEC median). Lower 36.26 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer Anhui Rinengzhongtian Semiconductor Development QJM220-60 rates 220.0 W.
Where Does Centrosolar America DP60 220 Fall Across Listed CEC Models?
Distribution marker showing Centrosolar America DP60 220 (220.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Centrosolar America DP60 220?
Dataset percentiles tracking Centrosolar America DP60 220 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Centrosolar America DP60 220?
Benchmark highlights for Centrosolar America DP60 220 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
220.0 W STC · Higher Than 3.8%
220.0 W STC (-165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.42% Aperture Efficiency
Power density 134.1 W/m2 (6.49 percentage points below 19.91% CEC median). PTC/STC ratio: 89.8% (rank #19,481).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.46 V at -10 C (566.4 V string) and 41.66 V at -20 C (14 max).
37 Panels = 8,140 W STC
Occupies 60.7 m2 (653 sq ft) producing 7,311 W PTC; NEC 690.8 OCPD floor is 13.2 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.26 * (1 + (-0.331/100) * (-10 - 25)) = 40.46 V | OCPD = 1.56 * 8.46 = 13.2 A
Inputs from CEC Modules.csv for Centrosolar America DP60 220: Voc=36.26 V, beta_Voc=-0.331%/C, Isc=8.46 A, STC=220.0 W, Area=1.64 m2.
Result: 14 panels max on 600 V (566.4 V); 37 panels for 8 kW (653 sq ft).
What Are the Published CEC Specifications for Centrosolar America DP60 220?
Official CEC datasheet figures for Centrosolar America DP60 220 (Multi-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 220.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 197.6 W (89.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.26 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.46 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 27.64 V / 7.96 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.331 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.42% (1.64 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Centrosolar America DP60 220 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Centrosolar America DP60 220 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 28 | 6.16 kW | 494 sq ft | $1,542 | $2,607 |
| 8 kW Class | 37 | 8.14 kW | 653 sq ft | $2,037 | $3,445 |
| 10 kW Class | 46 | 10.12 kW | 812 sq ft | $2,533 | $4,283 |
How Many Centrosolar America DP60 220 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Centrosolar America DP60 220 (40.46 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.66 V | 14 panels | 583.2 V | 24 panels |
| -10 C (14 F) | 40.46 V | 14 panels | 566.4 V | 24 panels |
| 0 C (32 F) | 39.26 V | 15 panels | 588.9 V | 25 panels |
| 25 C (77 F STC) | 36.26 V | 16 panels | 580.2 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DP60 220?
Competing CEC solar panels closest to Centrosolar America DP60 220 in nameplate wattage and Voc, starting with Anhui Rinengzhongtian Semiconductor Development QJM220-60.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Anhui Rinengzhongtian Semiconductor Development QJM220-60 Anhui Rinengzhongtian Semiconductor Development |
220.0 W | Tie (0 W) | 36.29 V | 13.52% | 89.8% |
| Alps Technology ATI-M660-220 Alps Technology |
220.0 W | Tie (0 W) | 36.06 V | 13.67% | 86.0% |
| Anji Technology AJP-M660-220 Anji Technology |
220.0 W | Tie (0 W) | 36.06 V | 13.55% | 86.0% |
| Gintung Energy ASEC-220G6S Gintung Energy |
220.0 W | Tie (0 W) | 36.53 V | 13.66% | 89.5% |
What Are the Design Limits and Best-Fit Uses for Centrosolar America DP60 220?
Evaluate Centrosolar America DP60 220 (220.0 W STC, 36.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DP60 220 reaches 41.66 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 37 panels for an 8 kW build require 653 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (653 sq ft).
- 2026 tax credit baseline: cash residential installs of Centrosolar America DP60 220 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Centrosolar America DP60 220 8 kW Residential Fit
Needs 37 modules (653 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM220-60.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 197.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Centrosolar America DP60 220 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.
How many Centrosolar America DP60 220 panels fit on a 600 V winter solar string?
At -10 C (14 F), Centrosolar America DP60 220 cold Voc rises from 36.26 V to 40.46 V (beta_Voc -0.331%/C), capping a 600 V string at 14 panels (566.4 V).
How much roof area does an 8 kW array of Centrosolar America DP60 220 need?
An 8 kW DC system uses 37 Centrosolar America DP60 220 modules (8,140 W STC / 7,311 W PTC), covering roughly 653 sq ft and saving ~$2,037/yr at 18.54 c/kWh.
How does Centrosolar America DP60 220 compare against Anhui Rinengzhongtian Semiconductor Development QJM220-60?
Centrosolar America DP60 220 outputs 220.0 W STC (36.26 V Voc, rank #20,759 of 21,677), while Anhui Rinengzhongtian Semiconductor Development QJM220-60 delivers 220.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)