Anji Technology AJP-M660-220 is a 220.0 W STC (189.1 W PTC) Multi-c-Si solar module ranking #20,759 of 21,677 CEC listings (below all-CEC median; higher than 3.8% of peers). It delivers 13.55% efficiency, 36.06 V Voc at 25 C, and 40.63 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 220.0 W
- PTC Wattage
- 189.1 W
- Voc @ 25C
- 36.06 V
- Efficiency
- 13.55%
How Does Anji Technology AJP-M660-220 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Anji Technology AJP-M660-220 (Multi-c-Si) residential solar systems.
Homeowners evaluating Anji Technology AJP-M660-220 need 28 panels for 6 kW or 37 panels (647 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (647 sq ft). Under NEC 690.7(A), beta_Voc (-0.362%/C) pushes open-circuit voltage to 40.63 V at 14 F and 41.93 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Anji Technology AJP-M660-220 Fall Across Listed CEC Models?
Comparison of Anji Technology AJP-M660-220 (220.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Dataset Percentiles Define Anji Technology AJP-M660-220?
Relative ranking of Anji Technology AJP-M660-220 across nameplate watts, 86.0% PTC thermal ratio, and module aperture efficiency. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Do the Dataset Ranks Show for Anji Technology AJP-M660-220?
Summary of Anji Technology AJP-M660-220 output rank, 8 kW array size (37 panels), efficiency rating, and 600 V string limit.
220.0 W STC · Higher Than 3.8%
220.0 W STC (-165.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.55% Aperture Efficiency
Power density 135.5 W/m2 (6.36 percentage points below 19.91% CEC median). PTC/STC ratio: 86.0% (rank #21,644).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.63 V at -10 C (568.8 V string) and 41.93 V at -20 C (14 max).
37 Panels = 8,140 W STC
Occupies 60.1 m2 (647 sq ft) producing 6,997 W PTC; NEC 690.8 OCPD floor is 12.4 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.06 * (1 + (-0.362/100) * (-10 - 25)) = 40.63 V | OCPD = 1.56 * 7.95 = 12.4 A
Inputs from CEC Modules.csv for Anji Technology AJP-M660-220: Voc=36.06 V, beta_Voc=-0.362%/C, Isc=7.95 A, STC=220.0 W, Area=1.624 m2.
Result: 14 panels max on 600 V (568.8 V); 37 panels for 8 kW (647 sq ft).
What Are the Published CEC Specifications for Anji Technology AJP-M660-220?
Complete CEC test sheet for Anji Technology AJP-M660-220 including Isc (7.95 A), Voc (36.06 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 220.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 189.1 W (86.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.06 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 7.95 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.12 V / 7.3 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.362 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.55% (1.624 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Anji Technology AJP-M660-220 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Anji Technology AJP-M660-220.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 28 | 6.16 kW | 489 sq ft | $1,542 | $2,607 |
| 8 kW Class | 37 | 8.14 kW | 647 sq ft | $2,037 | $3,445 |
| 10 kW Class | 46 | 10.12 kW | 804 sq ft | $2,533 | $4,283 |
How Many Anji Technology AJP-M660-220 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Anji Technology AJP-M660-220 (36.06 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.93 V | 14 panels | 587.0 V | 23 panels |
| -10 C (14 F) | 40.63 V | 14 panels | 568.8 V | 24 panels |
| 0 C (32 F) | 39.32 V | 15 panels | 589.8 V | 25 panels |
| 25 C (77 F STC) | 36.06 V | 16 panels | 577.0 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Anji Technology AJP-M660-220?
Four comparable CEC modules such as Alps Technology ATI-M660-220 (220.0 W) for side-by-side solar quote checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Alps Technology ATI-M660-220 Alps Technology |
220.0 W | Tie (0 W) | 36.06 V | 13.67% | 86.0% |
| Centrosolar America DP60 220 Centrosolar America |
220.0 W | Tie (0 W) | 36.26 V | 13.42% | 89.8% |
| Anhui Rinengzhongtian Semiconductor Development QJM220-60 Anhui Rinengzhongtian Semiconductor Development |
220.0 W | Tie (0 W) | 36.29 V | 13.52% | 89.8% |
| Gintung Energy ASEC-220G6S Gintung Energy |
220.0 W | Tie (0 W) | 36.53 V | 13.66% | 89.5% |
What Are the Design Limits and Best-Fit Uses for Anji Technology AJP-M660-220?
Evaluate Anji Technology AJP-M660-220 (220.0 W STC, 36.06 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Anji Technology AJP-M660-220 reaches 41.93 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 37 panels for an 8 kW build require 647 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 37 panels (647 sq ft).
- 2026 tax credit baseline: cash residential installs of Anji Technology AJP-M660-220 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Anji Technology AJP-M660-220 8 kW Residential Fit
Needs 37 modules (647 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Alps Technology ATI-M660-220.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 189.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Anji Technology AJP-M660-220 by Anji Technology grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Anji Technology AJP-M660-220 PTC wattage (189.1 W) lower than STC (220.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 189.1 W PTC (86.0% retention) across Anji Technology AJP-M660-220's 1.624 m2 aperture.
Who should skip Anji Technology AJP-M660-220 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 37 Anji Technology AJP-M660-220 panels (647 sq ft) leave unusable roof gaps vs. Alps Technology ATI-M660-220.
What is the 1,000 V commercial string limit for Anji Technology AJP-M660-220?
On 1,000 V commercial inverters at -10 C (40.63 V cold Voc), Anji Technology AJP-M660-220 fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Anji Technology AJP-M660-220.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)