Skip to main content
WireAndSun
Calculators
CEC PV Module

Anji Technology AJP-S572-180 — CEC Solar Module Specifications

Manufacturer: Anji Technology Registry: CEC Verified Engineering Specification

Anji Technology AJP-S572-180 is a 180.0 W STC (155.7 W PTC) Mono-c-Si solar module ranking #21,232 of 21,677 CEC listings (below all-CEC median; higher than 1.8% of peers). It delivers 13.84% efficiency, 44.06 V Voc at 25 C, and 49.64 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
180.0 W
PTC Wattage
155.7 W
Voc @ 25C
44.06 V
Efficiency
13.84%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Anji Technology AJP-S572-180 Compare Against Peer CEC Listings?

Solar engineering breakdown for Anji Technology AJP-S572-180: PTC thermal retention, roof footprint, and cold Voc string bounds. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Across 5,889 Mono-c-Si listings from Anji Technology and peers, Anji Technology AJP-S572-180 stands 230.0 W below the 410.0 W Mono-c-Si median and typical 86.5% PTC-to-STC thermal output (155.7 W real-world rating). Sizing 6 kW (34 panels) to 10 kW (56 panels) yields $1,532-$2,523/yr in baseline US bill offset. Mid-range 44.06 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Anji Technology AJP-S572-180 Fall Across Listed CEC Models?

Distribution marker showing Anji Technology AJP-S572-180 (180.0 W) relative to the 385.0 W all-CEC solar panel median. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Anji Technology AJP-S572-180 (180.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAnji Technology AJ: 180.0 W

What Dataset Percentiles Define Anji Technology AJP-S572-180?

Dataset percentiles tracking Anji Technology AJP-S572-180 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Anji Technology AJP-S572-180 Engineering BenchmarksPercentile comparison of Anji Technology AJP-S572-180 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage180.0 WPTC/STC Retention86.5%Module Efficiency13.84%

What Do the Dataset Ranks Show for Anji Technology AJP-S572-180?

Benchmark highlights for Anji Technology AJP-S572-180 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #21,232 / 21,677

180.0 W STC · Higher Than 1.8%

180.0 W STC (-205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #21,017

13.84% Aperture Efficiency

Power density 138.5 W/m2 (6.07 percentage points below 19.91% CEC median). PTC/STC ratio: 86.5% (rank #21,624).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.64 V at -10 C (595.7 V string) and 51.24 V at -20 C (11 max).

8 kW Reference Array

45 Panels = 8,100 W STC

Occupies 58.5 m2 (630 sq ft) producing 7,006 W PTC; NEC 690.8 OCPD floor is 8.28 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.06 * (1 + (-0.362/100) * (-10 - 25)) = 49.64 V | OCPD = 1.56 * 5.31 = 8.28 A

Inputs from CEC Modules.csv for Anji Technology AJP-S572-180: Voc=44.06 V, beta_Voc=-0.362%/C, Isc=5.31 A, STC=180.0 W, Area=1.3 m2.

Result: 12 panels max on 600 V (595.7 V); 45 panels for 8 kW (630 sq ft).

What Are the Published CEC Specifications for Anji Technology AJP-S572-180?

Official CEC datasheet figures for Anji Technology AJP-S572-180 (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Anji Technology AJP-S572-180.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 180.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 155.7 W (86.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.06 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.31 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.72 V / 4.9 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.362 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.84% (1.3 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Anji Technology AJP-S572-180 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Anji Technology AJP-S572-180 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 34 6.12 kW 476 sq ft $1,532 $2,590
8 kW Class 45 8.1 kW 630 sq ft $2,027 $3,428
10 kW Class 56 10.08 kW 784 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Anji Technology Series?

Consolidated Anji Technology wattage variants sharing the Anji Technology AJP-S572-180 mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Anji Technology AJP-S572-180 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Anji Technology AJP-S572-175 175.0 W 151.2 W 43.99 V 36.63 V 13.46%
Anji Technology AJP-S572-180 180.0 W 155.7 W 44.06 V 36.72 V 13.84%
Anji Technology AJP-S572-185 185.0 W 160.2 W 44.14 V 36.72 V 14.23%

How Many Anji Technology AJP-S572-180 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Anji Technology AJP-S572-180 (49.64 V at 14 F).

Computed from Voc=44.06V and beta_Voc=-0.362%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.24 V 11 panels 563.6 V 19 panels
-10 C (14 F) 49.64 V 12 panels 595.7 V 20 panels
0 C (32 F) 48.05 V 12 panels 576.6 V 20 panels
25 C (77 F STC) 44.06 V 13 panels 572.8 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Anji Technology AJP-S572-180?

Competing CEC solar panels closest to Anji Technology AJP-S572-180 in nameplate wattage and Voc, starting with Alps Technology ATI-S572-180.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Alps Technology ATI-S572-180
Alps Technology
180.0 W Tie (0 W) 44.06 V 13.98% 86.5%
Guangdong Golden Glass Technologies GG180S1-36/1589x807
Guangdong Golden Glass Technologies
180.0 W Tie (0 W) 44.2 V 14.04% 90.8%
Trina Solar TSM-180DA01
Trina Solar
180.0 W Tie (0 W) 44.2 V 14.26% 90.6%
Solarbest Energy-Tech (Zhejiang) ZSB-M180(125)
Solarbest Energy-Tech (Zhejiang)
180.0 W Tie (0 W) 44.35 V 14.1% 89.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Anji Technology AJP-S572-180?

Evaluate Anji Technology AJP-S572-180 (180.0 W STC, 44.06 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Anji Technology AJP-S572-180 reaches 51.24 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 45 panels for an 8 kW build require 630 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (630 sq ft).
  • 2026 tax credit baseline: cash residential installs of Anji Technology AJP-S572-180 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Anji Technology AJP-S572-180 8 kW Residential Fit

Needs 45 modules (630 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Alps Technology ATI-S572-180.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 155.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Anji Technology AJP-S572-180 by Anji Technology grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Anji Technology AJP-S572-180?

Multiplying Anji Technology AJP-S572-180's 5.31 A short-circuit current by 1.56 equals 8.28 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Anji Technology AJP-S572-180 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.64 V cold Voc at 14 F and handles 5.31 A Isc; string inverters cap Anji Technology AJP-S572-180 at 12 panels on 600 V.

Is Anji Technology AJP-S572-180 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Anji Technology AJP-S572-180 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.