Skip to main content
WireAndSun
Calculators
CEC PV Module

Anji Technology AJP-M660-235 — CEC Solar Module Specifications

Manufacturer: Anji Technology Registry: CEC Verified Engineering Specification

Anji Technology AJP-M660-235 is a 235.0 W STC (208.7 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.47% efficiency, 36.72 V Voc at 25 C, and 41.33 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
208.7 W
Voc @ 25C
36.72 V
Efficiency
14.47%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Anji Technology AJP-M660-235 Compare Against Peer CEC Listings?

Engineering position of Anji Technology AJP-M660-235 (235.0 W STC) vs. Advance Power API-P235 across 1,407 CEC Multi-c-Si solar modules.

Ranking #20,368 across 21,677 CEC solar panels (below all-CEC median; higher than 5.4% of peers), Anji Technology AJP-M660-235 operates as a compact residential or specialty off-grid module sitting 43.8 W below the 278.8 W Multi-c-Si median. Lower 36.72 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters. With typical 88.8% PTC-to-STC thermal output (208.7 W real-world rating), 35 panels occupy 612 sq ft and offset roughly $2,057/yr at average US rates (or $3,479/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Anji Technology AJP-M660-235 Fall Across Listed CEC Models?

Plots Anji Technology AJP-M660-235 at 235.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Anji Technology AJP-M660-235 (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAnji Technology AJ: 235.0 W

What Dataset Percentiles Define Anji Technology AJP-M660-235?

Benchmarks Anji Technology AJP-M660-235 on STC wattage, thermal PTC/STC retention, and 14.47 aperture conversion efficiency against CEC peers.

Anji Technology AJP-M660-235 Engineering BenchmarksPercentile comparison of Anji Technology AJP-M660-235 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention88.8%Module Efficiency14.47%

What Do the Dataset Ranks Show for Anji Technology AJP-M660-235?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Anji Technology AJP-M660-235 by Anji Technology.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,451

14.47% Aperture Efficiency

Power density 144.7 W/m2 (5.44 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.33 V at -10 C (578.6 V string) and 42.65 V at -20 C (14 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 56.8 m2 (612 sq ft) producing 7,304 W PTC; NEC 690.8 OCPD floor is 12.84 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.72 * (1 + (-0.359/100) * (-10 - 25)) = 41.33 V | OCPD = 1.56 * 8.23 = 12.84 A

Inputs from CEC Modules.csv for Anji Technology AJP-M660-235: Voc=36.72 V, beta_Voc=-0.359%/C, Isc=8.23 A, STC=235.0 W, Area=1.624 m2.

Result: 14 panels max on 600 V (578.6 V); 35 panels for 8 kW (612 sq ft).

What Are the Published CEC Specifications for Anji Technology AJP-M660-235?

Laboratory test ratings recorded for Anji Technology AJP-M660-235 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Anji Technology AJP-M660-235.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 208.7 W (88.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.72 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.23 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.6 V / 7.68 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.359 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.47% (1.624 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Anji Technology AJP-M660-235 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (612 sq ft at 8 kW), and estimated Year-1 electric bill offset for Anji Technology AJP-M660-235.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 454 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 612 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 752 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This Anji Technology Series?

Sibling wattage bins and frame colors grouped with Anji Technology AJP-M660-235 under Anji Technology to prevent duplicate spec pages.

Sibling CEC listings grouped into the Anji Technology AJP-M660-235 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Anji Technology AJP-M660-225 225.0 W 193.5 W 36.24 V 30.24 V 13.86%
Anji Technology AJP-M660-230 230.0 W 204.1 W 36.42 V 30.36 V 14.16%
Anji Technology AJP-M660-235 235.0 W 208.7 W 36.72 V 30.6 V 14.47%
Anji Technology AJP-M660-240 240.0 W 213.3 W 36.84 V 30.72 V 14.78%
Anji Technology AJP-M660-245 245.0 W 217.9 W 37.08 V 30.84 V 15.09%

How Many Anji Technology AJP-M660-235 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Anji Technology AJP-M660-235 (beta_Voc -0.359%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=36.72V and beta_Voc=-0.359%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.65 V 14 panels 597.1 V 23 panels
-10 C (14 F) 41.33 V 14 panels 578.6 V 24 panels
0 C (32 F) 40.02 V 14 panels 560.3 V 24 panels
25 C (77 F STC) 36.72 V 16 panels 587.5 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Anji Technology AJP-M660-235?

Closest cross-brand CEC competitors to Anji Technology AJP-M660-235 matched near 235.0 W STC and 36.72 V Voc, led by Advance Power API-P235.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-P235
Advance Power
235.0 W Tie (0 W) 36.72 V 14.35% 89.2%
Alps Technology ATI-M660-235
Alps Technology
235.0 W Tie (0 W) 36.72 V 14.6% 86.2%
Auxin Solar AXN6P610T235
Auxin Solar
235.0 W Tie (0 W) 36.72 V 14.35% 89.2%
Eoplly New Energy Technology EP156P/60-235S AC
Eoplly New Energy Technology
235.0 W Tie (0 W) 36.72 V 14.38% 89.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Anji Technology AJP-M660-235?

Evaluate Anji Technology AJP-M660-235 (235.0 W STC, 36.72 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Anji Technology AJP-M660-235 reaches 42.65 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 612 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (612 sq ft).
  • 2026 tax credit baseline: cash residential installs of Anji Technology AJP-M660-235 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Anji Technology AJP-M660-235 8 kW Residential Fit

Needs 35 modules (612 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Advance Power API-P235.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 208.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Anji Technology AJP-M660-235 by Anji Technology grounded in CEC test data and NEC 690.7/690.8 limits.

How many Anji Technology AJP-M660-235 panels fit on a 600 V winter solar string?

At -10 C (14 F), Anji Technology AJP-M660-235 cold Voc rises from 36.72 V to 41.33 V (beta_Voc -0.359%/C), capping a 600 V string at 14 panels (578.6 V).

How much roof area does an 8 kW array of Anji Technology AJP-M660-235 need?

An 8 kW DC system uses 35 Anji Technology AJP-M660-235 modules (8,225 W STC / 7,304 W PTC), covering roughly 612 sq ft and saving ~$2,057/yr at 18.54 c/kWh.

How does Anji Technology AJP-M660-235 compare against Advance Power API-P235?

Anji Technology AJP-M660-235 outputs 235.0 W STC (36.72 V Voc, rank #20,368 of 21,677), while Advance Power API-P235 delivers 235.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.