Auxin Solar AXN6P610T235 is a 235.0 W STC (209.6 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.35% efficiency, 36.72 V Voc at 25 C, and 41.01 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 235.0 W
- PTC Wattage
- 209.6 W
- Voc @ 25C
- 36.72 V
- Efficiency
- 14.35%
How Does Auxin Solar AXN6P610T235 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Auxin Solar AXN6P610T235 (Multi-c-Si) residential solar systems.
Homeowners evaluating Auxin Solar AXN6P610T235 need 26 panels for 6 kW or 35 panels (617 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (617 sq ft). Under NEC 690.7(A), beta_Voc (-0.334%/C) pushes open-circuit voltage to 41.01 V at 14 F and 42.24 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Auxin Solar AXN6P610T235 Fall Across Listed CEC Models?
Comparison of Auxin Solar AXN6P610T235 (235.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Dataset Percentiles Define Auxin Solar AXN6P610T235?
Relative ranking of Auxin Solar AXN6P610T235 across nameplate watts, 89.2% PTC thermal ratio, and module aperture efficiency. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Do the Dataset Ranks Show for Auxin Solar AXN6P610T235?
Summary of Auxin Solar AXN6P610T235 output rank, 8 kW array size (35 panels), efficiency rating, and 600 V string limit.
235.0 W STC · Higher Than 5.4%
235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.35% Aperture Efficiency
Power density 143.5 W/m2 (5.56 percentage points below 19.91% CEC median). PTC/STC ratio: 89.2% (rank #20,311).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.01 V at -10 C (574.1 V string) and 42.24 V at -20 C (14 max).
35 Panels = 8,225 W STC
Occupies 57.3 m2 (617 sq ft) producing 7,336 W PTC; NEC 690.8 OCPD floor is 12.84 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.72 * (1 + (-0.334/100) * (-10 - 25)) = 41.01 V | OCPD = 1.56 * 8.23 = 12.84 A
Inputs from CEC Modules.csv for Auxin Solar AXN6P610T235: Voc=36.72 V, beta_Voc=-0.334%/C, Isc=8.23 A, STC=235.0 W, Area=1.638 m2.
Result: 14 panels max on 600 V (574.1 V); 35 panels for 8 kW (617 sq ft).
What Are the Published CEC Specifications for Auxin Solar AXN6P610T235?
Complete CEC test sheet for Auxin Solar AXN6P610T235 including Isc (8.23 A), Voc (36.72 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 235.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 209.6 W (89.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.72 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.23 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.6 V / 7.68 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.334 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.35% (1.638 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Auxin Solar AXN6P610T235 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Auxin Solar AXN6P610T235.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 26 | 6.11 kW | 458 sq ft | $1,529 | $2,586 |
| 8 kW Class | 35 | 8.22 kW | 617 sq ft | $2,057 | $3,479 |
| 10 kW Class | 43 | 10.11 kW | 758 sq ft | $2,530 | $4,279 |
Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?
Related Auxin Solar power steps and black/silver trims consolidated into this Auxin Solar AXN6P610T235 series guide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Auxin Solar AXN6P610T225 | 225.0 W | 200.5 W | 36.42 V | 30.36 V | 13.74% |
| Auxin Solar AXN6P610T230 | 230.0 W | 205.0 W | 36.6 V | 30.48 V | 14.04% |
| Auxin Solar AXN6P610T235 | 235.0 W | 209.6 W | 36.72 V | 30.6 V | 14.35% |
| Auxin Solar AXN6P610T240 | 240.0 W | 214.2 W | 36.72 V | 30.54 V | 14.65% |
| Auxin Solar AXN6P610T245 | 245.0 W | 218.8 W | 36.9 V | 30.84 V | 14.96% |
How Many Auxin Solar AXN6P610T235 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Auxin Solar AXN6P610T235 (36.72 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.24 V | 14 panels | 591.4 V | 23 panels |
| -10 C (14 F) | 41.01 V | 14 panels | 574.1 V | 24 panels |
| 0 C (32 F) | 39.79 V | 15 panels | 596.9 V | 25 panels |
| 25 C (77 F STC) | 36.72 V | 16 panels | 587.5 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN6P610T235?
Four comparable CEC modules such as Advance Power API-P235 (235.0 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-P235 Advance Power |
235.0 W | Tie (0 W) | 36.72 V | 14.35% | 89.2% |
| Alps Technology ATI-M660-235 Alps Technology |
235.0 W | Tie (0 W) | 36.72 V | 14.6% | 86.2% |
| Anji Technology AJP-M660-235 Anji Technology |
235.0 W | Tie (0 W) | 36.72 V | 14.47% | 88.8% |
| Eoplly New Energy Technology EP156P/60-235S AC Eoplly New Energy Technology |
235.0 W | Tie (0 W) | 36.72 V | 14.38% | 89.3% |
What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN6P610T235?
Evaluate Auxin Solar AXN6P610T235 (235.0 W STC, 36.72 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN6P610T235 reaches 42.24 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 35 panels for an 8 kW build require 617 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (617 sq ft).
- 2026 tax credit baseline: cash residential installs of Auxin Solar AXN6P610T235 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Auxin Solar AXN6P610T235 8 kW Residential Fit
Needs 35 modules (617 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Advance Power API-P235.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 209.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Auxin Solar AXN6P610T235 by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Auxin Solar AXN6P610T235 PTC wattage (209.6 W) lower than STC (235.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 209.6 W PTC (89.2% retention) across Auxin Solar AXN6P610T235's 1.638 m2 aperture.
Who should skip Auxin Solar AXN6P610T235 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 Auxin Solar AXN6P610T235 panels (617 sq ft) leave unusable roof gaps vs. Advance Power API-P235.
What is the 1,000 V commercial string limit for Auxin Solar AXN6P610T235?
On 1,000 V commercial inverters at -10 C (41.01 V cold Voc), Auxin Solar AXN6P610T235 fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Auxin Solar AXN6P610T235.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)