Skip to main content
WireAndSun
Calculators
CEC PV Module

Auxin Solar AXN6P610T235 — CEC Solar Module Specifications

Manufacturer: Auxin Solar Registry: CEC Verified Engineering Specification

Auxin Solar AXN6P610T235 is a 235.0 W STC (209.6 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.35% efficiency, 36.72 V Voc at 25 C, and 41.01 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
209.6 W
Voc @ 25C
36.72 V
Efficiency
14.35%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN6P610T235 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Auxin Solar AXN6P610T235 (Multi-c-Si) residential solar systems.

Homeowners evaluating Auxin Solar AXN6P610T235 need 26 panels for 6 kW or 35 panels (617 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (617 sq ft). Under NEC 690.7(A), beta_Voc (-0.334%/C) pushes open-circuit voltage to 41.01 V at 14 F and 42.24 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Auxin Solar AXN6P610T235 Fall Across Listed CEC Models?

Comparison of Auxin Solar AXN6P610T235 (235.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN6P610T235 (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN6P6: 235.0 W

What Dataset Percentiles Define Auxin Solar AXN6P610T235?

Relative ranking of Auxin Solar AXN6P610T235 across nameplate watts, 89.2% PTC thermal ratio, and module aperture efficiency. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Auxin Solar AXN6P610T235 Engineering BenchmarksPercentile comparison of Auxin Solar AXN6P610T235 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention89.2%Module Efficiency14.35%

What Do the Dataset Ranks Show for Auxin Solar AXN6P610T235?

Summary of Auxin Solar AXN6P610T235 output rank, 8 kW array size (35 panels), efficiency rating, and 600 V string limit.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,576

14.35% Aperture Efficiency

Power density 143.5 W/m2 (5.56 percentage points below 19.91% CEC median). PTC/STC ratio: 89.2% (rank #20,311).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.01 V at -10 C (574.1 V string) and 42.24 V at -20 C (14 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 57.3 m2 (617 sq ft) producing 7,336 W PTC; NEC 690.8 OCPD floor is 12.84 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.72 * (1 + (-0.334/100) * (-10 - 25)) = 41.01 V | OCPD = 1.56 * 8.23 = 12.84 A

Inputs from CEC Modules.csv for Auxin Solar AXN6P610T235: Voc=36.72 V, beta_Voc=-0.334%/C, Isc=8.23 A, STC=235.0 W, Area=1.638 m2.

Result: 14 panels max on 600 V (574.1 V); 35 panels for 8 kW (617 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN6P610T235?

Complete CEC test sheet for Auxin Solar AXN6P610T235 including Isc (8.23 A), Voc (36.72 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN6P610T235.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 209.6 W (89.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.72 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.23 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.6 V / 7.68 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.334 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.35% (1.638 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Auxin Solar AXN6P610T235 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Auxin Solar AXN6P610T235.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 458 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 617 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 758 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

Related Auxin Solar power steps and black/silver trims consolidated into this Auxin Solar AXN6P610T235 series guide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Auxin Solar AXN6P610T235 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Auxin Solar AXN6P610T225 225.0 W 200.5 W 36.42 V 30.36 V 13.74%
Auxin Solar AXN6P610T230 230.0 W 205.0 W 36.6 V 30.48 V 14.04%
Auxin Solar AXN6P610T235 235.0 W 209.6 W 36.72 V 30.6 V 14.35%
Auxin Solar AXN6P610T240 240.0 W 214.2 W 36.72 V 30.54 V 14.65%
Auxin Solar AXN6P610T245 245.0 W 218.8 W 36.9 V 30.84 V 14.96%

How Many Auxin Solar AXN6P610T235 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Auxin Solar AXN6P610T235 (36.72 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=36.72V and beta_Voc=-0.334%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.24 V 14 panels 591.4 V 23 panels
-10 C (14 F) 41.01 V 14 panels 574.1 V 24 panels
0 C (32 F) 39.79 V 15 panels 596.9 V 25 panels
25 C (77 F STC) 36.72 V 16 panels 587.5 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN6P610T235?

Four comparable CEC modules such as Advance Power API-P235 (235.0 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-P235
Advance Power
235.0 W Tie (0 W) 36.72 V 14.35% 89.2%
Alps Technology ATI-M660-235
Alps Technology
235.0 W Tie (0 W) 36.72 V 14.6% 86.2%
Anji Technology AJP-M660-235
Anji Technology
235.0 W Tie (0 W) 36.72 V 14.47% 88.8%
Eoplly New Energy Technology EP156P/60-235S AC
Eoplly New Energy Technology
235.0 W Tie (0 W) 36.72 V 14.38% 89.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN6P610T235?

Evaluate Auxin Solar AXN6P610T235 (235.0 W STC, 36.72 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN6P610T235 reaches 42.24 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 617 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (617 sq ft).
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN6P610T235 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN6P610T235 8 kW Residential Fit

Needs 35 modules (617 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Advance Power API-P235.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 209.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN6P610T235 by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Auxin Solar AXN6P610T235 PTC wattage (209.6 W) lower than STC (235.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 209.6 W PTC (89.2% retention) across Auxin Solar AXN6P610T235's 1.638 m2 aperture.

Who should skip Auxin Solar AXN6P610T235 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 35 Auxin Solar AXN6P610T235 panels (617 sq ft) leave unusable roof gaps vs. Advance Power API-P235.

What is the 1,000 V commercial string limit for Auxin Solar AXN6P610T235?

On 1,000 V commercial inverters at -10 C (41.01 V cold Voc), Auxin Solar AXN6P610T235 fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Auxin Solar AXN6P610T235.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls