Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-180DA01 — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-180DA01 is a 180.0 W STC (163.1 W PTC) Mono-c-Si solar module ranking #21,232 of 21,677 CEC listings (below all-CEC median; higher than 1.8% of peers). It delivers 14.26% efficiency, 44.2 V Voc at 25 C, and 49.15 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
180.0 W
PTC Wattage
163.1 W
Voc @ 25C
44.2 V
Efficiency
14.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-180DA01 Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-180DA01 handles rooftop heat (163.1 W PTC), 8 kW sizing, and cold winter string voltage.

Trina Solar builds the Trina Solar TSM-180DA01 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 142.6 W/m2 (5.65 percentage points below 19.91% CEC median). Compared against Guangdong Golden Glass Technologies GG180S1-36/1589x807 (180.0 W), this model holds typical 90.6% PTC-to-STC thermal output (163.1 W real-world rating). Mid-range 44.2 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 8.35 A overcurrent floor served by a 15 A breaker.

Where Does Trina Solar TSM-180DA01 Fall Across Listed CEC Models?

Where Trina Solar TSM-180DA01 (180.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-180DA01 (180.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-18: 180.0 W

What Dataset Percentiles Define Trina Solar TSM-180DA01?

Percentile placement of Trina Solar TSM-180DA01 across power density (142.6 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-180DA01 Engineering BenchmarksPercentile comparison of Trina Solar TSM-180DA01 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage180.0 WPTC/STC Retention90.6%Module Efficiency14.26%

What Do the Dataset Ranks Show for Trina Solar TSM-180DA01?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-180DA01 specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #21,232 / 21,677

180.0 W STC · Higher Than 1.8%

180.0 W STC (-205.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,651

14.26% Aperture Efficiency

Power density 142.6 W/m2 (5.65 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.15 V at -10 C (589.8 V string) and 50.56 V at -20 C (11 max).

8 kW Reference Array

45 Panels = 8,100 W STC

Occupies 56.8 m2 (611 sq ft) producing 7,340 W PTC; NEC 690.8 OCPD floor is 8.35 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.2 * (1 + (-0.32/100) * (-10 - 25)) = 49.15 V | OCPD = 1.56 * 5.35 = 8.35 A

Inputs from CEC Modules.csv for Trina Solar TSM-180DA01: Voc=44.2 V, beta_Voc=-0.32%/C, Isc=5.35 A, STC=180.0 W, Area=1.262 m2.

Result: 12 panels max on 600 V (589.8 V); 45 panels for 8 kW (611 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-180DA01?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-180DA01.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-180DA01.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 180.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 163.1 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.8 V / 4.9 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.32 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.26% (1.262 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-180DA01 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-180DA01 (180.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 34 6.12 kW 462 sq ft $1,532 $2,590
8 kW Class 45 8.1 kW 611 sq ft $2,027 $3,428
10 kW Class 56 10.08 kW 761 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-180DA01 architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Trina Solar TSM-180DA01 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-175DA01 175.0 W 158.5 W 43.9 V 36.2 V 13.86%
Trina Solar TSM-180DA01 180.0 W 163.1 W 44.2 V 36.8 V 14.26%
Trina Solar TSM-185DA01 185.0 W 164.3 W 44.5 V 37.5 V 14.66%

How Many Trina Solar TSM-180DA01 Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-180DA01 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.2V and beta_Voc=-0.32%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.56 V 11 panels 556.2 V 19 panels
-10 C (14 F) 49.15 V 12 panels 589.8 V 20 panels
0 C (32 F) 47.74 V 12 panels 572.9 V 20 panels
25 C (77 F STC) 44.2 V 13 panels 574.6 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-180DA01?

Alternative CEC solar modules from competing brands near Trina Solar TSM-180DA01 (180.0 W), including Guangdong Golden Glass Technologies GG180S1-36/1589x807.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Guangdong Golden Glass Technologies GG180S1-36/1589x807
Guangdong Golden Glass Technologies
180.0 W Tie (0 W) 44.2 V 14.04% 90.8%
Alps Technology ATI-S572-180
Alps Technology
180.0 W Tie (0 W) 44.06 V 13.98% 86.5%
Anji Technology AJP-S572-180
Anji Technology
180.0 W Tie (0 W) 44.06 V 13.84% 86.5%
Solarbest Energy-Tech (Zhejiang) ZSB-M180(125)
Solarbest Energy-Tech (Zhejiang)
180.0 W Tie (0 W) 44.35 V 14.1% 89.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-180DA01?

Evaluate Trina Solar TSM-180DA01 (180.0 W STC, 44.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-180DA01 reaches 50.56 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 45 panels for an 8 kW build require 611 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 45 panels (611 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-180DA01 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-180DA01 8 kW Residential Fit

Needs 45 modules (611 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Guangdong Golden Glass Technologies GG180S1-36/1589x807.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 163.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-180DA01 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-180DA01?

Multiplying Trina Solar TSM-180DA01's 5.35 A short-circuit current by 1.56 equals 8.35 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Trina Solar TSM-180DA01 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.15 V cold Voc at 14 F and handles 5.35 A Isc; string inverters cap Trina Solar TSM-180DA01 at 12 panels on 600 V.

Is Trina Solar TSM-180DA01 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-180DA01 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.