US Solar USS-QCMI2-54-210 is a 210.0 W STC (185.7 W PTC) Multi-c-Si solar module ranking #20,916 of 21,677 CEC listings (below all-CEC median; higher than 3.2% of peers). It delivers 14.16% efficiency, 33.23 V Voc at 25 C, and 37.42 V cold Voc at -10 C (16 panels max per 600 V string).
- STC Wattage
- 210.0 W
- PTC Wattage
- 185.7 W
- Voc @ 25C
- 33.23 V
- Efficiency
- 14.16%
How Does US Solar USS-QCMI2-54-210 Compare Against Peer CEC Listings?
How US Solar US Solar USS-QCMI2-54-210 handles rooftop heat (185.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, US Solar USS-QCMI2-54-210 exhibits 8.5 A short-circuit current, requiring a 13.26 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,916 of 21,677 (68.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 57.8 m2 for an 8 kW system (48 panels for 10 kW). Lower 33.23 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters.
Where Does US Solar USS-QCMI2-54-210 Fall Across Listed CEC Models?
Where US Solar USS-QCMI2-54-210 (210.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define US Solar USS-QCMI2-54-210?
Percentile placement of US Solar USS-QCMI2-54-210 across power density (141.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for US Solar USS-QCMI2-54-210?
Four critical engineering numbers homeowners and solar installers check first when reviewing US Solar USS-QCMI2-54-210 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
210.0 W STC · Higher Than 3.2%
210.0 W STC (-175.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.16% Aperture Efficiency
Power density 141.6 W/m2 (5.75 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).
16 Panels Max @ -10 C (600 V)
Cold Voc reaches 37.42 V at -10 C (598.7 V string) and 38.61 V at -20 C (15 max).
39 Panels = 8,190 W STC
Occupies 57.8 m2 (623 sq ft) producing 7,242 W PTC; NEC 690.8 OCPD floor is 13.26 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 33.23 * (1 + (-0.36/100) * (-10 - 25)) = 37.42 V | OCPD = 1.56 * 8.5 = 13.26 A
Inputs from CEC Modules.csv for US Solar USS-QCMI2-54-210: Voc=33.23 V, beta_Voc=-0.36%/C, Isc=8.5 A, STC=210.0 W, Area=1.483 m2.
Result: 16 panels max on 600 V (598.7 V); 39 panels for 8 kW (623 sq ft).
What Are the Published CEC Specifications for US Solar USS-QCMI2-54-210?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for US Solar USS-QCMI2-54-210.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 210.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 185.7 W (88.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 33.23 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.5 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 26.25 V / 8.0 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.16% (1.483 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Multi-c-Si) | Monofacial backsheet |
How Many US Solar USS-QCMI2-54-210 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using US Solar USS-QCMI2-54-210 (210.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 29 | 6.09 kW | 463 sq ft | $1,524 | $2,577 |
| 8 kW Class | 39 | 8.19 kW | 623 sq ft | $2,050 | $3,466 |
| 10 kW Class | 48 | 10.08 kW | 766 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This US Solar Series?
All closely matched US Solar wattages and cosmetic trims sharing the US Solar USS-QCMI2-54-210 architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| US Solar USS-QCMI2-54-200 | 200.0 W | 176.6 W | 32.8 V | 25.25 V | 13.49% |
| US Solar USS-QCMI2-54-205 | 205.0 W | 181.2 W | 33.01 V | 25.72 V | 13.82% |
| US Solar USS-QCMI2-54-210 | 210.0 W | 185.7 W | 33.23 V | 26.25 V | 14.16% |
| US Solar USS-QCMI2-54-215 | 215.0 W | 190.3 W | 33.44 V | 26.81 V | 14.5% |
| US Solar USS-QCMI2-54-220 | 220.0 W | 194.8 W | 33.66 V | 27.33 V | 14.83% |
How Many US Solar USS-QCMI2-54-210 Modules Fit in a Cold-Weather String?
Maximum series module counts for US Solar USS-QCMI2-54-210 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 38.61 V | 15 panels | 579.1 V | 25 panels |
| -10 C (14 F) | 37.42 V | 16 panels | 598.7 V | 26 panels |
| 0 C (32 F) | 36.22 V | 16 panels | 579.5 V | 27 panels |
| 25 C (77 F STC) | 33.23 V | 18 panels | 598.1 V | 30 panels |
Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI2-54-210?
Alternative CEC solar modules from competing brands near US Solar USS-QCMI2-54-210 (210.0 W), including Centrosolar America DP54 210.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP54 210 Centrosolar America |
210.0 W | Tie (0 W) | 33.23 V | 14.16% | 88.4% |
| APOS Energy AS210 APOS Energy |
210.0 W | Tie (0 W) | 33.5 V | 14.0% | 89.7% |
| Guangdong Golden Glass Technologies GG205M2-27/1482x992 Guangdong Golden Glass Technologies |
205.0 W | -5.0 W | 33.2 V | 13.94% | 89.9% |
| Hanwha Qcells (Qidong) Co Ltd SF190-27-M205 Hanwha Qcells (Qidong) Co Ltd |
205.0 W | -5.0 W | 33.1 V | 13.72% | 88.9% |
What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI2-54-210?
Evaluate US Solar USS-QCMI2-54-210 (210.0 W STC, 33.23 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI2-54-210 reaches 38.61 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
- Footprint constraint: 39 panels for an 8 kW build require 623 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (623 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI2-54-210 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
US Solar USS-QCMI2-54-210 8 kW Residential Fit
Needs 39 modules (623 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 16 panels (-10 C) or 15 panels (-20 C), or compare Centrosolar America DP54 210.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 185.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for US Solar USS-QCMI2-54-210 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is US Solar USS-QCMI2-54-210 PTC wattage (185.7 W) lower than STC (210.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 185.7 W PTC (88.4% retention) across US Solar USS-QCMI2-54-210's 1.483 m2 aperture.
Who should skip US Solar USS-QCMI2-54-210 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 39 US Solar USS-QCMI2-54-210 panels (623 sq ft) leave unusable roof gaps vs. Centrosolar America DP54 210.
What is the 1,000 V commercial string limit for US Solar USS-QCMI2-54-210?
On 1,000 V commercial inverters at -10 C (37.42 V cold Voc), US Solar USS-QCMI2-54-210 fits up to 26 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting US Solar USS-QCMI2-54-210.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)