US Solar USS-QCMI2-54-210 — CEC Solar Module Specifications

Manufacturer: US Solar Registry: CEC Verified Engineering Specification

US Solar USS-QCMI2-54-210 is a 210.0 W STC (185.7 W PTC) Multi-c-Si solar module ranking #20,916 of 21,677 CEC listings (below all-CEC median; higher than 3.2% of peers). It delivers 14.16% efficiency, 33.23 V Voc at 25 C, and 37.42 V cold Voc at -10 C (16 panels max per 600 V string).

STC Wattage
210.0 W
PTC Wattage
185.7 W
Voc @ 25C
33.23 V
Efficiency
14.16%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does US Solar USS-QCMI2-54-210 Compare Against Peer CEC Listings?

How US Solar US Solar USS-QCMI2-54-210 handles rooftop heat (185.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, US Solar USS-QCMI2-54-210 exhibits 8.5 A short-circuit current, requiring a 13.26 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #20,916 of 21,677 (68.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 57.8 m2 for an 8 kW system (48 panels for 10 kW). Lower 33.23 V string voltage fits 16 panels in series at 14 F and pairs easily with microinverters.

Where Does US Solar USS-QCMI2-54-210 Fall Across Listed CEC Models?

Where US Solar USS-QCMI2-54-210 (210.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where US Solar USS-QCMI2-54-210 (210.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCUS Solar USS-QCMI2: 210.0 W

What Dataset Percentiles Define US Solar USS-QCMI2-54-210?

Percentile placement of US Solar USS-QCMI2-54-210 across power density (141.6 W/m2), thermal retention, and nameplate STC wattage.

US Solar USS-QCMI2-54-210 Engineering BenchmarksPercentile comparison of US Solar USS-QCMI2-54-210 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage210.0 WPTC/STC Retention88.4%Module Efficiency14.16%

What Do the Dataset Ranks Show for US Solar USS-QCMI2-54-210?

Four critical engineering numbers homeowners and solar installers check first when reviewing US Solar USS-QCMI2-54-210 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #20,916 / 21,677

210.0 W STC · Higher Than 3.2%

210.0 W STC (-175.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,764

14.16% Aperture Efficiency

Power density 141.6 W/m2 (5.75 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).

NEC 690.7 Limit

16 Panels Max @ -10 C (600 V)

Cold Voc reaches 37.42 V at -10 C (598.7 V string) and 38.61 V at -20 C (15 max).

8 kW Reference Array

39 Panels = 8,190 W STC

Occupies 57.8 m2 (623 sq ft) producing 7,242 W PTC; NEC 690.8 OCPD floor is 13.26 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 33.23 * (1 + (-0.36/100) * (-10 - 25)) = 37.42 V | OCPD = 1.56 * 8.5 = 13.26 A

Inputs from CEC Modules.csv for US Solar USS-QCMI2-54-210: Voc=33.23 V, beta_Voc=-0.36%/C, Isc=8.5 A, STC=210.0 W, Area=1.483 m2.

Result: 16 panels max on 600 V (598.7 V); 39 panels for 8 kW (623 sq ft).

What Are the Published CEC Specifications for US Solar USS-QCMI2-54-210?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for US Solar USS-QCMI2-54-210.

Official California Energy Commission (NREL SAM) test parameters for US Solar USS-QCMI2-54-210.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 210.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 185.7 W (88.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 33.23 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.5 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 26.25 V / 8.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.36 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.16% (1.483 m2) Array roof footprint density
Cell Count & Technology 54 cells (Multi-c-Si) Monofacial backsheet

How Many US Solar USS-QCMI2-54-210 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using US Solar USS-QCMI2-54-210 (210.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 29 6.09 kW 463 sq ft $1,524 $2,577
8 kW Class 39 8.19 kW 623 sq ft $2,050 $3,466
10 kW Class 48 10.08 kW 766 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This US Solar Series?

All closely matched US Solar wattages and cosmetic trims sharing the US Solar USS-QCMI2-54-210 architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the US Solar USS-QCMI2-54-210 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
US Solar USS-QCMI2-54-200 200.0 W 176.6 W 32.8 V 25.25 V 13.49%
US Solar USS-QCMI2-54-205 205.0 W 181.2 W 33.01 V 25.72 V 13.82%
US Solar USS-QCMI2-54-210 210.0 W 185.7 W 33.23 V 26.25 V 14.16%
US Solar USS-QCMI2-54-215 215.0 W 190.3 W 33.44 V 26.81 V 14.5%
US Solar USS-QCMI2-54-220 220.0 W 194.8 W 33.66 V 27.33 V 14.83%

How Many US Solar USS-QCMI2-54-210 Modules Fit in a Cold-Weather String?

Maximum series module counts for US Solar USS-QCMI2-54-210 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=33.23V and beta_Voc=-0.36%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 38.61 V 15 panels 579.1 V 25 panels
-10 C (14 F) 37.42 V 16 panels 598.7 V 26 panels
0 C (32 F) 36.22 V 16 panels 579.5 V 27 panels
25 C (77 F STC) 33.23 V 18 panels 598.1 V 30 panels

Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI2-54-210?

Alternative CEC solar modules from competing brands near US Solar USS-QCMI2-54-210 (210.0 W), including Centrosolar America DP54 210.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DP54 210
Centrosolar America
210.0 W Tie (0 W) 33.23 V 14.16% 88.4%
APOS Energy AS210
APOS Energy
210.0 W Tie (0 W) 33.5 V 14.0% 89.7%
Guangdong Golden Glass Technologies GG205M2-27/1482x992
Guangdong Golden Glass Technologies
205.0 W -5.0 W 33.2 V 13.94% 89.9%
Hanwha Qcells (Qidong) Co Ltd SF190-27-M205
Hanwha Qcells (Qidong) Co Ltd
205.0 W -5.0 W 33.1 V 13.72% 88.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI2-54-210?

Evaluate US Solar USS-QCMI2-54-210 (210.0 W STC, 33.23 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI2-54-210 reaches 38.61 V per panel—exceeding 15 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 39 panels for an 8 kW build require 623 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 39 panels (623 sq ft).
  • 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI2-54-210 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

US Solar USS-QCMI2-54-210 8 kW Residential Fit

Needs 39 modules (623 sq ft) with a 15 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 16 panels (-10 C) or 15 panels (-20 C), or compare Centrosolar America DP54 210.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 185.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for US Solar USS-QCMI2-54-210 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is US Solar USS-QCMI2-54-210 PTC wattage (185.7 W) lower than STC (210.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 185.7 W PTC (88.4% retention) across US Solar USS-QCMI2-54-210's 1.483 m2 aperture.

Who should skip US Solar USS-QCMI2-54-210 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 39 US Solar USS-QCMI2-54-210 panels (623 sq ft) leave unusable roof gaps vs. Centrosolar America DP54 210.

What is the 1,000 V commercial string limit for US Solar USS-QCMI2-54-210?

On 1,000 V commercial inverters at -10 C (37.42 V cold Voc), US Solar USS-QCMI2-54-210 fits up to 26 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting US Solar USS-QCMI2-54-210.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.