US Solar USS-QCMI2-48-185 is a 185.0 W STC (163.5 W PTC) Multi-c-Si solar module ranking #21,185 of 21,677 CEC listings (below all-CEC median; higher than 2.1% of peers). It delivers 13.96% efficiency, 29.49 V Voc at 25 C, and 33.21 V cold Voc at -10 C (18 panels max per 600 V string).
- STC Wattage
- 185.0 W
- PTC Wattage
- 163.5 W
- Voc @ 25C
- 29.49 V
- Efficiency
- 13.96%
How Does US Solar USS-QCMI2-48-185 Compare Against Peer CEC Listings?
Solar engineering breakdown for US Solar USS-QCMI2-48-185: PTC thermal retention, roof footprint, and cold Voc string bounds. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
Measured at 185.0 W STC and 163.5 W PTC, US Solar USS-QCMI2-48-185 sits -200.0 W vs all-CEC median (below all-CEC median; higher than 2.1% of peers) among 21,677 listed modules. Power density reaches 139.6 W/m2 (5.95 percentage points below 19.91% CEC median). Lower 29.49 V string voltage fits 18 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 30 panels in series. Alternative peer Centrosolar America DP48 185 rates 185.0 W.
Where Does US Solar USS-QCMI2-48-185 Fall Across Listed CEC Models?
Distribution marker showing US Solar USS-QCMI2-48-185 (185.0 W) relative to the 385.0 W all-CEC solar panel median. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Dataset Percentiles Define US Solar USS-QCMI2-48-185?
Dataset percentiles tracking US Solar USS-QCMI2-48-185 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Do the Dataset Ranks Show for US Solar USS-QCMI2-48-185?
Benchmark highlights for US Solar USS-QCMI2-48-185 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
185.0 W STC · Higher Than 2.1%
185.0 W STC (-200.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.96% Aperture Efficiency
Power density 139.6 W/m2 (5.95 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).
18 Panels Max @ -10 C (600 V)
Cold Voc reaches 33.21 V at -10 C (597.8 V string) and 34.27 V at -20 C (17 max).
44 Panels = 8,140 W STC
Occupies 58.3 m2 (628 sq ft) producing 7,194 W PTC; NEC 690.8 OCPD floor is 13.31 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 29.49 * (1 + (-0.36/100) * (-10 - 25)) = 33.21 V | OCPD = 1.56 * 8.53 = 13.31 A
Inputs from CEC Modules.csv for US Solar USS-QCMI2-48-185: Voc=29.49 V, beta_Voc=-0.36%/C, Isc=8.53 A, STC=185.0 W, Area=1.325 m2.
Result: 18 panels max on 600 V (597.8 V); 44 panels for 8 kW (628 sq ft).
What Are the Published CEC Specifications for US Solar USS-QCMI2-48-185?
Official CEC datasheet figures for US Solar USS-QCMI2-48-185 (Multi-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 185.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 163.5 W (88.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 29.49 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.53 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 23.04 V / 8.03 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.96% (1.325 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Multi-c-Si) | Monofacial backsheet |
How Many US Solar USS-QCMI2-48-185 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many US Solar USS-QCMI2-48-185 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 33 | 6.11 kW | 471 sq ft | $1,529 | $2,586 |
| 8 kW Class | 44 | 8.14 kW | 628 sq ft | $2,037 | $3,445 |
| 10 kW Class | 55 | 10.18 kW | 784 sq ft | $2,548 | $4,308 |
Which Sibling Wattage & Trim Variants Belong to This US Solar Series?
Consolidated US Solar wattage variants sharing the US Solar USS-QCMI2-48-185 mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| US Solar USS-QCMI2-48-175 | 175.0 W | 154.5 W | 29.01 V | 22.1 V | 13.2% |
| US Solar USS-QCMI2-48-180 | 180.0 W | 159.0 W | 29.2 V | 22.56 V | 13.58% |
| US Solar USS-QCMI2-48-185 | 185.0 W | 163.5 W | 29.49 V | 23.04 V | 13.96% |
| US Solar USS-QCMI2-48-190 | 190.0 W | 168.1 W | 29.73 V | 23.54 V | 14.34% |
| US Solar USS-QCMI2-48-195 | 195.0 W | 172.7 W | 29.92 V | 24.07 V | 14.71% |
How Many US Solar USS-QCMI2-48-185 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on US Solar USS-QCMI2-48-185 (33.21 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 34.27 V | 17 panels | 582.6 V | 29 panels |
| -10 C (14 F) | 33.21 V | 18 panels | 597.8 V | 30 panels |
| 0 C (32 F) | 32.14 V | 18 panels | 578.5 V | 31 panels |
| 25 C (77 F STC) | 29.49 V | 20 panels | 589.8 V | 33 panels |
Which Cross-Brand Solar Modules Compare Closest to US Solar USS-QCMI2-48-185?
Competing CEC solar panels closest to US Solar USS-QCMI2-48-185 in nameplate wattage and Voc, starting with Centrosolar America DP48 185.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America DP48 185 Centrosolar America |
185.0 W | Tie (0 W) | 29.49 V | 13.96% | 88.4% |
| Solartech Energy ASC-6P-48-185 Solartech Energy |
185.0 W | Tie (0 W) | 29.49 V | 13.96% | 88.4% |
| APOS Energy AS185 APOS Energy |
185.0 W | Tie (0 W) | 29.78 V | 13.8% | 89.6% |
| Lightway Green New Energy LW185(23)P1310x990 Lightway Green New Energy |
185.0 W | Tie (0 W) | 30.0 V | 14.41% | 89.6% |
What Are the Design Limits and Best-Fit Uses for US Solar USS-QCMI2-48-185?
Evaluate US Solar USS-QCMI2-48-185 (185.0 W STC, 29.49 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), US Solar USS-QCMI2-48-185 reaches 34.27 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
- Footprint constraint: 44 panels for an 8 kW build require 628 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 44 panels (628 sq ft).
- 2026 tax credit baseline: cash residential installs of US Solar USS-QCMI2-48-185 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
US Solar USS-QCMI2-48-185 8 kW Residential Fit
Needs 44 modules (628 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 18 panels (-10 C) or 17 panels (-20 C), or compare Centrosolar America DP48 185.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 163.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for US Solar USS-QCMI2-48-185 by US Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many US Solar USS-QCMI2-48-185 panels fit on a 600 V winter solar string?
At -10 C (14 F), US Solar USS-QCMI2-48-185 cold Voc rises from 29.49 V to 33.21 V (beta_Voc -0.36%/C), capping a 600 V string at 18 panels (597.8 V).
How much roof area does an 8 kW array of US Solar USS-QCMI2-48-185 need?
An 8 kW DC system uses 44 US Solar USS-QCMI2-48-185 modules (8,140 W STC / 7,194 W PTC), covering roughly 628 sq ft and saving ~$2,037/yr at 18.54 c/kWh.
How does US Solar USS-QCMI2-48-185 compare against Centrosolar America DP48 185?
US Solar USS-QCMI2-48-185 outputs 185.0 W STC (29.49 V Voc, rank #21,185 of 21,677), while Centrosolar America DP48 185 delivers 185.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)