Centrosolar America DP48 185 is a 185.0 W STC (163.5 W PTC) Multi-c-Si solar module ranking #21,185 of 21,677 CEC listings (below all-CEC median; higher than 2.1% of peers). It delivers 13.96% efficiency, 29.49 V Voc at 25 C, and 33.21 V cold Voc at -10 C (18 panels max per 600 V string).
- STC Wattage
- 185.0 W
- PTC Wattage
- 163.5 W
- Voc @ 25C
- 29.49 V
- Efficiency
- 13.96%
How Does Centrosolar America DP48 185 Compare Against Peer CEC Listings?
Solar engineering breakdown for Centrosolar America DP48 185: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 185.0 W STC and 163.5 W PTC, Centrosolar America DP48 185 sits -200.0 W vs all-CEC median (below all-CEC median; higher than 2.1% of peers) among 21,677 listed modules. Power density reaches 139.6 W/m2 (5.95 percentage points below 19.91% CEC median). Lower 29.49 V string voltage fits 18 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 30 panels in series. Alternative peer Solartech Energy ASC-6P-48-185 rates 185.0 W.
Where Does Centrosolar America DP48 185 Fall Across Listed CEC Models?
Distribution marker showing Centrosolar America DP48 185 (185.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Centrosolar America DP48 185?
Dataset percentiles tracking Centrosolar America DP48 185 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Centrosolar America DP48 185?
Benchmark highlights for Centrosolar America DP48 185 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
185.0 W STC · Higher Than 2.1%
185.0 W STC (-200.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.96% Aperture Efficiency
Power density 139.6 W/m2 (5.95 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).
18 Panels Max @ -10 C (600 V)
Cold Voc reaches 33.21 V at -10 C (597.8 V string) and 34.27 V at -20 C (17 max).
44 Panels = 8,140 W STC
Occupies 58.3 m2 (628 sq ft) producing 7,194 W PTC; NEC 690.8 OCPD floor is 13.31 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 29.49 * (1 + (-0.36/100) * (-10 - 25)) = 33.21 V | OCPD = 1.56 * 8.53 = 13.31 A
Inputs from CEC Modules.csv for Centrosolar America DP48 185: Voc=29.49 V, beta_Voc=-0.36%/C, Isc=8.53 A, STC=185.0 W, Area=1.325 m2.
Result: 18 panels max on 600 V (597.8 V); 44 panels for 8 kW (628 sq ft).
What Are the Published CEC Specifications for Centrosolar America DP48 185?
Official CEC datasheet figures for Centrosolar America DP48 185 (Multi-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 185.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 163.5 W (88.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 29.49 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.53 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 23.04 V / 8.03 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.36 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.96% (1.325 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Multi-c-Si) | Monofacial backsheet |
How Many Centrosolar America DP48 185 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Centrosolar America DP48 185 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 33 | 6.11 kW | 471 sq ft | $1,529 | $2,586 |
| 8 kW Class | 44 | 8.14 kW | 628 sq ft | $2,037 | $3,445 |
| 10 kW Class | 55 | 10.18 kW | 784 sq ft | $2,548 | $4,308 |
Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?
Consolidated Centrosolar America wattage variants sharing the Centrosolar America DP48 185 mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Centrosolar America DP48 175 | 175.0 W | 154.5 W | 29.01 V | 22.1 V | 13.2% |
| Centrosolar America DP48 180 | 180.0 W | 159.0 W | 29.2 V | 22.56 V | 13.58% |
| Centrosolar America DP48 185 | 185.0 W | 163.5 W | 29.49 V | 23.04 V | 13.96% |
| Centrosolar America DP48 190 | 190.0 W | 168.1 W | 29.73 V | 23.54 V | 14.34% |
| Centrosolar America DP48 195 | 195.0 W | 172.7 W | 29.92 V | 24.07 V | 14.71% |
How Many Centrosolar America DP48 185 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Centrosolar America DP48 185 (33.21 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 34.27 V | 17 panels | 582.6 V | 29 panels |
| -10 C (14 F) | 33.21 V | 18 panels | 597.8 V | 30 panels |
| 0 C (32 F) | 32.14 V | 18 panels | 578.5 V | 31 panels |
| 25 C (77 F STC) | 29.49 V | 20 panels | 589.8 V | 33 panels |
Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DP48 185?
Competing CEC solar panels closest to Centrosolar America DP48 185 in nameplate wattage and Voc, starting with Solartech Energy ASC-6P-48-185.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Solartech Energy ASC-6P-48-185 Solartech Energy |
185.0 W | Tie (0 W) | 29.49 V | 13.96% | 88.4% |
| US Solar USS-QCMI2-48-185 US Solar |
185.0 W | Tie (0 W) | 29.49 V | 13.96% | 88.4% |
| APOS Energy AS185 APOS Energy |
185.0 W | Tie (0 W) | 29.78 V | 13.8% | 89.6% |
| Lightway Green New Energy LW185(23)P1310x990 Lightway Green New Energy |
185.0 W | Tie (0 W) | 30.0 V | 14.41% | 89.6% |
What Are the Design Limits and Best-Fit Uses for Centrosolar America DP48 185?
Evaluate Centrosolar America DP48 185 (185.0 W STC, 29.49 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DP48 185 reaches 34.27 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
- Footprint constraint: 44 panels for an 8 kW build require 628 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 44 panels (628 sq ft).
- 2026 tax credit baseline: cash residential installs of Centrosolar America DP48 185 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Centrosolar America DP48 185 8 kW Residential Fit
Needs 44 modules (628 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 18 panels (-10 C) or 17 panels (-20 C), or compare Solartech Energy ASC-6P-48-185.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 163.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Centrosolar America DP48 185 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.
How many Centrosolar America DP48 185 panels fit on a 600 V winter solar string?
At -10 C (14 F), Centrosolar America DP48 185 cold Voc rises from 29.49 V to 33.21 V (beta_Voc -0.36%/C), capping a 600 V string at 18 panels (597.8 V).
How much roof area does an 8 kW array of Centrosolar America DP48 185 need?
An 8 kW DC system uses 44 Centrosolar America DP48 185 modules (8,140 W STC / 7,194 W PTC), covering roughly 628 sq ft and saving ~$2,037/yr at 18.54 c/kWh.
How does Centrosolar America DP48 185 compare against Solartech Energy ASC-6P-48-185?
Centrosolar America DP48 185 outputs 185.0 W STC (29.49 V Voc, rank #21,185 of 21,677), while Solartech Energy ASC-6P-48-185 delivers 185.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)