Lightway Green New Energy LW185(23)P1310x990 — CEC Solar Module Specifications

Manufacturer: Lightway Green New Energy Registry: CEC Verified Engineering Specification

Lightway Green New Energy LW185(23)P1310x990 is a 185.0 W STC (165.7 W PTC) Multi-c-Si solar module ranking #21,185 of 21,677 CEC listings (below all-CEC median; higher than 2.1% of peers). It delivers 14.41% efficiency, 30.0 V Voc at 25 C, and 33.78 V cold Voc at -10 C (17 panels max per 600 V string).

STC Wattage
185.0 W
PTC Wattage
165.7 W
Voc @ 25C
30.0 V
Efficiency
14.41%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Lightway Green New Energy LW185(23)P1310x990 Compare Against Peer CEC Listings?

How Lightway Green New Energy Lightway Green New Energy LW185(23)P1310x990 handles rooftop heat (165.7 W PTC), 8 kW sizing, and cold winter string voltage.

Lightway Green New Energy builds the Lightway Green New Energy LW185(23)P1310x990 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 144.1 W/m2 (5.50 percentage points below 19.91% CEC median). Compared against APOS Energy AS185 (185.0 W), this model holds typical 89.6% PTC-to-STC thermal output (165.7 W real-world rating). Lower 30.0 V string voltage fits 17 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 13.04 A overcurrent floor served by a 15 A breaker.

Where Does Lightway Green New Energy LW185(23)P1310x990 Fall Across Listed CEC Models?

Where Lightway Green New Energy LW185(23)P1310x990 (185.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Lightway Green New Energy LW185(23)P1310x990 (185.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLightway Green New: 185.0 W

What Dataset Percentiles Define Lightway Green New Energy LW185(23)P1310x990?

Percentile placement of Lightway Green New Energy LW185(23)P1310x990 across power density (144.1 W/m2), thermal retention, and nameplate STC wattage.

Lightway Green New Energy LW185(23)P1310x990 Engineering BenchmarksPercentile comparison of Lightway Green New Energy LW185(23)P1310x990 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage185.0 WPTC/STC Retention89.6%Module Efficiency14.41%

What Do the Dataset Ranks Show for Lightway Green New Energy LW185(23)P1310x990?

Four critical engineering numbers homeowners and solar installers check first when reviewing Lightway Green New Energy LW185(23)P1310x990 specifications.

Rank #21,185 / 21,677

185.0 W STC · Higher Than 2.1%

185.0 W STC (-200.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,524

14.41% Aperture Efficiency

Power density 144.1 W/m2 (5.50 percentage points below 19.91% CEC median). PTC/STC ratio: 89.6% (rank #19,798).

NEC 690.7 Limit

17 Panels Max @ -10 C (600 V)

Cold Voc reaches 33.78 V at -10 C (574.3 V string) and 34.86 V at -20 C (17 max).

8 kW Reference Array

44 Panels = 8,140 W STC

Occupies 56.5 m2 (608 sq ft) producing 7,291 W PTC; NEC 690.8 OCPD floor is 13.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 30.0 * (1 + (-0.36/100) * (-10 - 25)) = 33.78 V | OCPD = 1.56 * 8.36 = 13.04 A

Inputs from CEC Modules.csv for Lightway Green New Energy LW185(23)P1310x990: Voc=30.0 V, beta_Voc=-0.36%/C, Isc=8.36 A, STC=185.0 W, Area=1.284 m2.

Result: 17 panels max on 600 V (574.3 V); 44 panels for 8 kW (608 sq ft).

What Are the Published CEC Specifications for Lightway Green New Energy LW185(23)P1310x990?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Lightway Green New Energy LW185(23)P1310x990.

Official California Energy Commission (NREL SAM) test parameters for Lightway Green New Energy LW185(23)P1310x990.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 185.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 165.7 W (89.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 30.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.36 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 24.0 V / 7.83 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.36 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.41% (1.284 m2) Array roof footprint density
Cell Count & Technology 48 cells (Multi-c-Si) Monofacial backsheet

How Many Lightway Green New Energy LW185(23)P1310x990 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Lightway Green New Energy LW185(23)P1310x990 (185.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 33 6.11 kW 456 sq ft $1,529 $2,586
8 kW Class 44 8.14 kW 608 sq ft $2,037 $3,445
10 kW Class 55 10.18 kW 760 sq ft $2,548 $4,308

How Many Lightway Green New Energy LW185(23)P1310x990 Modules Fit in a Cold-Weather String?

Maximum series module counts for Lightway Green New Energy LW185(23)P1310x990 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=30.0V and beta_Voc=-0.36%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 34.86 V 17 panels 592.6 V 28 panels
-10 C (14 F) 33.78 V 17 panels 574.3 V 29 panels
0 C (32 F) 32.7 V 18 panels 588.6 V 30 panels
25 C (77 F STC) 30.0 V 20 panels 600.0 V 33 panels

Which Cross-Brand Solar Modules Compare Closest to Lightway Green New Energy LW185(23)P1310x990?

Alternative CEC solar modules from competing brands near Lightway Green New Energy LW185(23)P1310x990 (185.0 W), including APOS Energy AS185.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
APOS Energy AS185
APOS Energy
185.0 W Tie (0 W) 29.78 V 13.8% 89.6%
Centrosolar America DP48 185
Centrosolar America
185.0 W Tie (0 W) 29.49 V 13.96% 88.4%
Solartech Energy ASC-6P-48-185
Solartech Energy
185.0 W Tie (0 W) 29.49 V 13.96% 88.4%
US Solar USS-QCMI2-48-185
US Solar
185.0 W Tie (0 W) 29.49 V 13.96% 88.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Lightway Green New Energy LW185(23)P1310x990?

Evaluate Lightway Green New Energy LW185(23)P1310x990 (185.0 W STC, 30.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Lightway Green New Energy LW185(23)P1310x990 reaches 34.86 V per panel—exceeding 17 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 44 panels for an 8 kW build require 608 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 44 panels (608 sq ft).
  • 2026 tax credit baseline: cash residential installs of Lightway Green New Energy LW185(23)P1310x990 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Lightway Green New Energy LW185(23)P1310x990 8 kW Residential Fit

Needs 44 modules (608 sq ft) with a 15 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 17 panels (-10 C) or 17 panels (-20 C), or compare APOS Energy AS185.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 165.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Lightway Green New Energy LW185(23)P1310x990 by Lightway Green New Energy grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Lightway Green New Energy LW185(23)P1310x990?

Multiplying Lightway Green New Energy LW185(23)P1310x990's 8.36 A short-circuit current by 1.56 equals 13.04 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Lightway Green New Energy LW185(23)P1310x990 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 33.78 V cold Voc at 14 F and handles 8.36 A Isc; string inverters cap Lightway Green New Energy LW185(23)P1310x990 at 17 panels on 600 V.

Is Lightway Green New Energy LW185(23)P1310x990 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Lightway Green New Energy LW185(23)P1310x990 rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.