Thornova Solar TS-SBT60(490) is a 490.0 W STC (466.2 W PTC) Mono-c-Si solar module ranking #4,659 of 21,677 CEC listings (top 21.8%; higher than 78.2% of peers). It delivers 22.9% efficiency, 43.42 V Voc at 25 C, and 46.93 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 490.0 W
- PTC Wattage
- 466.2 W
- Voc @ 25C
- 43.42 V
- Efficiency
- 22.9%
How Does Thornova Solar TS-SBT60(490) Compare Against Peer CEC Listings?
How Thornova Solar Thornova Solar TS-SBT60(490) handles rooftop heat (466.2 W PTC), 8 kW sizing, and cold winter string voltage.
Thornova Solar builds the Thornova Solar TS-SBT60(490) (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 229.0 W/m2 (2.99 percentage points above 19.91% CEC median). Compared against DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M (490.0 W), this model holds strong 95.1% PTC-to-STC heat retention (#713 of 21,677). Mid-range 43.42 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 21.43 A overcurrent floor served by a 25 A breaker.
Where Does Thornova Solar TS-SBT60(490) Fall Across Listed CEC Models?
Where Thornova Solar TS-SBT60(490) (490.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Thornova Solar TS-SBT60(490)?
Percentile placement of Thornova Solar TS-SBT60(490) across power density (229.0 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Thornova Solar TS-SBT60(490)?
Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-SBT60(490) specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
Top 21.8% STC Output
490.0 W STC (+105.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.9% Aperture Efficiency
Power density 229.0 W/m2 (2.99 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 46.93 V at -10 C (563.2 V string) and 47.93 V at -20 C (12 max).
17 Panels = 8,330 W STC
Occupies 36.4 m2 (392 sq ft) producing 7,925 W PTC; NEC 690.8 OCPD floor is 21.43 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.42 * (1 + (-0.231/100) * (-10 - 25)) = 46.93 V | OCPD = 1.56 * 13.74 = 21.43 A
Inputs from CEC Modules.csv for Thornova Solar TS-SBT60(490): Voc=43.42 V, beta_Voc=-0.231%/C, Isc=13.74 A, STC=490.0 W, Area=2.14 m2.
Result: 12 panels max on 600 V (563.2 V); 17 panels for 8 kW (392 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-SBT60(490)?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-SBT60(490).
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 490.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 466.2 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.42 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.74 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.2 V / 13.18 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.231 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.9% (2.14 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Thornova Solar TS-SBT60(490) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-SBT60(490) (490.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.37 kW | 299 sq ft | $1,594 | $2,696 |
| 8 kW Class | 17 | 8.33 kW | 392 sq ft | $2,085 | $3,525 |
| 10 kW Class | 21 | 10.29 kW | 484 sq ft | $2,575 | $4,355 |
How Many Thornova Solar TS-SBT60(490) Modules Fit in a Cold-Weather String?
Maximum series module counts for Thornova Solar TS-SBT60(490) from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 47.93 V | 12 panels | 575.2 V | 20 panels |
| -10 C (14 F) | 46.93 V | 12 panels | 563.2 V | 21 panels |
| 0 C (32 F) | 45.93 V | 13 panels | 597.1 V | 21 panels |
| 25 C (77 F STC) | 43.42 V | 13 panels | 564.5 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-SBT60(490)?
Alternative CEC solar modules from competing brands near Thornova Solar TS-SBT60(490) (490.0 W), including DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M DONGGUAN SUNWORTH SOLAR ENERGY CO LTD |
490.0 W | Tie (0 W) | 44.21 V | 25.79% | 95.0% |
| Hanersun Energy Co Ltd HN18N-60HT485W Hanersun Energy Co Ltd |
485.0 W | -5.0 W | 43.0 V | 22.99% | 94.9% |
| Auxin Solar AXN10M485B Auxin Solar |
485.0 W | -5.0 W | 43.98 V | 22.56% | 92.0% |
| Auxin Solar AXN10M485W Auxin Solar |
485.0 W | -5.0 W | 43.98 V | 22.56% | 91.8% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-SBT60(490)?
Evaluate Thornova Solar TS-SBT60(490) (490.0 W STC, 43.42 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-SBT60(490) reaches 47.93 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 392 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (392 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-SBT60(490) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-SBT60(490) 8 kW Residential Fit
Needs 17 modules (392 sq ft) with a 25 A string OCPD, offsetting ~$2,085/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare DONGGUAN SUNWORTH SOLAR ENERGY CO LTD SW490M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 466.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-SBT60(490) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-SBT60(490)?
Multiplying Thornova Solar TS-SBT60(490)'s 13.74 A short-circuit current by 1.56 equals 21.43 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Thornova Solar TS-SBT60(490) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 46.93 V cold Voc at 14 F and handles 13.74 A Isc; string inverters cap Thornova Solar TS-SBT60(490) at 12 panels on 600 V.
Is Thornova Solar TS-SBT60(490) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-SBT60(490) rely on utility bill offset (~$2,085/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)