Thornova Solar TS-BGT66(725)-G12 is a 725.0 W STC (689.8 W PTC) Mono-c-Si solar module ranking #52 of 21,677 CEC listings (top 0.4%; higher than 99.6% of peers). It delivers 23.54% efficiency, 49.6 V Voc at 25 C, and 53.52 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 725.0 W
- PTC Wattage
- 689.8 W
- Voc @ 25C
- 49.6 V
- Efficiency
- 23.54%
How Does Thornova Solar TS-BGT66(725)-G12 Compare Against Peer CEC Listings?
Solar engineering breakdown for Thornova Solar TS-BGT66(725)-G12: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 725.0 W STC and 689.8 W PTC, Thornova Solar TS-BGT66(725)-G12 sits +340.0 W vs all-CEC median (top 0.4%; higher than 99.6% of peers) among 21,677 listed modules. Power density reaches 235.4 W/m2 (3.63 percentage points above 19.91% CEC median). Higher 49.6 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Trina Solar CoLtd TSM-725NEG21C20 rates 725.0 W.
Where Does Thornova Solar TS-BGT66(725)-G12 Fall Across Listed CEC Models?
Distribution marker showing Thornova Solar TS-BGT66(725)-G12 (725.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Thornova Solar TS-BGT66(725)-G12?
Dataset percentiles tracking Thornova Solar TS-BGT66(725)-G12 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Thornova Solar TS-BGT66(725)-G12?
Benchmark highlights for Thornova Solar TS-BGT66(725)-G12 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 0.4% STC Output
725.0 W STC (+340.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.54% Aperture Efficiency
Power density 235.4 W/m2 (3.63 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.52 V at -10 C (588.7 V string) and 54.64 V at -20 C (10 max).
12 Panels = 8,700 W STC
Occupies 37.0 m2 (398 sq ft) producing 8,278 W PTC; NEC 690.8 OCPD floor is 28.89 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.6 * (1 + (-0.226/100) * (-10 - 25)) = 53.52 V | OCPD = 1.56 * 18.52 = 28.89 A
Inputs from CEC Modules.csv for Thornova Solar TS-BGT66(725)-G12: Voc=49.6 V, beta_Voc=-0.226%/C, Isc=18.52 A, STC=725.0 W, Area=3.08 m2.
Result: 11 panels max on 600 V (588.7 V); 12 panels for 8 kW (398 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BGT66(725)-G12?
Official CEC datasheet figures for Thornova Solar TS-BGT66(725)-G12 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 725.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 689.8 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.52 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.5 V / 17.45 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.226 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.54% (3.08 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BGT66(725)-G12 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Thornova Solar TS-BGT66(725)-G12 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 9 | 6.53 kW | 298 sq ft | $1,634 | $2,764 |
| 8 kW Class | 12 | 8.7 kW | 398 sq ft | $2,178 | $3,682 |
| 10 kW Class | 14 | 10.15 kW | 464 sq ft | $2,540 | $4,296 |
How Many Thornova Solar TS-BGT66(725)-G12 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-BGT66(725)-G12 (53.52 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.64 V | 10 panels | 546.4 V | 18 panels |
| -10 C (14 F) | 53.52 V | 11 panels | 588.7 V | 18 panels |
| 0 C (32 F) | 52.4 V | 11 panels | 576.4 V | 19 panels |
| 25 C (77 F STC) | 49.6 V | 12 panels | 595.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BGT66(725)-G12?
Competing CEC solar panels closest to Thornova Solar TS-BGT66(725)-G12 in nameplate wattage and Voc, starting with Trina Solar CoLtd TSM-725NEG21C20.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Trina Solar CoLtd TSM-725NEG21C20 Trina Solar CoLtd |
725.0 W | Tie (0 W) | 49.6 V | 23.31% | 95.3% |
| Boviet Solar Technology Co Ltd BVM8611M-725-H-HC-BF Boviet Solar Technology Co Ltd |
725.0 W | Tie (0 W) | 49.44 V | 24.91% | 95.4% |
| Boviet Solar Technology Co Ltd BVM8611M-725-H-HC-BF-DG Boviet Solar Technology Co Ltd |
725.0 W | Tie (0 W) | 49.44 V | 24.91% | 95.4% |
| SKYCELL USA SKY 725-BHDG24-USA SKYCELL USA |
725.0 W | Tie (0 W) | 50.88 V | 23.31% | 95.3% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BGT66(725)-G12?
Evaluate Thornova Solar TS-BGT66(725)-G12 (725.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BGT66(725)-G12 reaches 54.64 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 12 panels for an 8 kW build require 398 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BGT66(725)-G12 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BGT66(725)-G12 8 kW Residential Fit
Needs 12 modules (398 sq ft) with a 30 A string OCPD, offsetting ~$2,178/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Trina Solar CoLtd TSM-725NEG21C20.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 689.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BGT66(725)-G12 by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Thornova Solar TS-BGT66(725)-G12 panels fit on a 600 V winter solar string?
At -10 C (14 F), Thornova Solar TS-BGT66(725)-G12 cold Voc rises from 49.6 V to 53.52 V (beta_Voc -0.226%/C), capping a 600 V string at 11 panels (588.7 V).
How much roof area does an 8 kW array of Thornova Solar TS-BGT66(725)-G12 need?
An 8 kW DC system uses 12 Thornova Solar TS-BGT66(725)-G12 modules (8,700 W STC / 8,278 W PTC), covering roughly 398 sq ft and saving ~$2,178/yr at 18.54 c/kWh.
How does Thornova Solar TS-BGT66(725)-G12 compare against Trina Solar CoLtd TSM-725NEG21C20?
Thornova Solar TS-BGT66(725)-G12 outputs 725.0 W STC (49.6 V Voc, rank #52 of 21,677), while Trina Solar CoLtd TSM-725NEG21C20 delivers 725.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)