Skip to main content
WireAndSun
Calculators
CEC PV Module

SKYCELL USA SKY 725-BHDG24-USA — CEC Solar Module Specifications

Manufacturer: SKYCELL USA Registry: CEC Verified Engineering Specification

SKYCELL USA SKY 725-BHDG24-USA is a 725.0 W STC (691.2 W PTC) Mono-c-Si solar module ranking #52 of 21,677 CEC listings (top 0.4%; higher than 99.6% of peers). It delivers 23.31% efficiency, 50.88 V Voc at 25 C, and 55.01 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
725.0 W
PTC Wattage
691.2 W
Voc @ 25C
50.88 V
Efficiency
23.31%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SKYCELL USA SKY 725-BHDG24-USA Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for SKYCELL USA SKY 725-BHDG24-USA (Mono-c-Si) residential solar systems.

Homeowners evaluating SKYCELL USA SKY 725-BHDG24-USA need 9 panels for 6 kW or 12 panels (402 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.232%/C) pushes open-circuit voltage to 55.01 V at 14 F and 56.19 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does SKYCELL USA SKY 725-BHDG24-USA Fall Across Listed CEC Models?

Comparison of SKYCELL USA SKY 725-BHDG24-USA (725.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SKYCELL USA SKY 725-BHDG24-USA (725.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSKYCELL USA SKY 72: 725.0 W

What Dataset Percentiles Define SKYCELL USA SKY 725-BHDG24-USA?

Relative ranking of SKYCELL USA SKY 725-BHDG24-USA across nameplate watts, 95.3% PTC thermal ratio, and module aperture efficiency.

SKYCELL USA SKY 725-BHDG24-USA Engineering BenchmarksPercentile comparison of SKYCELL USA SKY 725-BHDG24-USA wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage725.0 WPTC/STC Retention95.3%Module Efficiency23.31%

What Do the Dataset Ranks Show for SKYCELL USA SKY 725-BHDG24-USA?

Summary of SKYCELL USA SKY 725-BHDG24-USA output rank, 8 kW array size (12 panels), efficiency rating, and 600 V string limit.

Rank #52 / 21,677

Top 0.4% STC Output

725.0 W STC (+340.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #701

23.31% Aperture Efficiency

Power density 233.1 W/m2 (3.40 percentage points above 19.91% CEC median). PTC/STC ratio: 95.3% (rank #237).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.01 V at -10 C (550.1 V string) and 56.19 V at -20 C (10 max).

8 kW Reference Array

12 Panels = 8,700 W STC

Occupies 37.3 m2 (402 sq ft) producing 8,294 W PTC; NEC 690.8 OCPD floor is 27.66 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.88 * (1 + (-0.232/100) * (-10 - 25)) = 55.01 V | OCPD = 1.56 * 17.73 = 27.66 A

Inputs from CEC Modules.csv for SKYCELL USA SKY 725-BHDG24-USA: Voc=50.88 V, beta_Voc=-0.232%/C, Isc=17.73 A, STC=725.0 W, Area=3.11 m2.

Result: 10 panels max on 600 V (550.1 V); 12 panels for 8 kW (402 sq ft).

What Are the Published CEC Specifications for SKYCELL USA SKY 725-BHDG24-USA?

Complete CEC test sheet for SKYCELL USA SKY 725-BHDG24-USA including Isc (17.73 A), Voc (50.88 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for SKYCELL USA SKY 725-BHDG24-USA.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 725.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 691.2 W (95.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.88 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 17.73 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.83 V / 16.93 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.232 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.31% (3.11 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Bifacial glass-glass

How Many SKYCELL USA SKY 725-BHDG24-USA Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using SKYCELL USA SKY 725-BHDG24-USA.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 9 6.53 kW 301 sq ft $1,634 $2,764
8 kW Class 12 8.7 kW 402 sq ft $2,178 $3,682
10 kW Class 14 10.15 kW 469 sq ft $2,540 $4,296

How Many SKYCELL USA SKY 725-BHDG24-USA Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for SKYCELL USA SKY 725-BHDG24-USA (50.88 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=50.88V and beta_Voc=-0.232%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.19 V 10 panels 561.9 V 17 panels
-10 C (14 F) 55.01 V 10 panels 550.1 V 18 panels
0 C (32 F) 53.83 V 11 panels 592.1 V 18 panels
25 C (77 F STC) 50.88 V 11 panels 559.7 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to SKYCELL USA SKY 725-BHDG24-USA?

Four comparable CEC modules such as Thornova Solar TS-BGT66(725)-G12 (725.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Thornova Solar TS-BGT66(725)-G12
Thornova Solar
725.0 W Tie (0 W) 49.6 V 23.54% 95.1%
Trina Solar CoLtd TSM-725NEG21C20
Trina Solar CoLtd
725.0 W Tie (0 W) 49.6 V 23.31% 95.3%
Boviet Solar Technology Co Ltd BVM8611M-725-H-HC-BF
Boviet Solar Technology Co Ltd
725.0 W Tie (0 W) 49.44 V 24.91% 95.4%
Boviet Solar Technology Co Ltd BVM8611M-725-H-HC-BF-DG
Boviet Solar Technology Co Ltd
725.0 W Tie (0 W) 49.44 V 24.91% 95.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SKYCELL USA SKY 725-BHDG24-USA?

Evaluate SKYCELL USA SKY 725-BHDG24-USA (725.0 W STC, 50.88 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SKYCELL USA SKY 725-BHDG24-USA reaches 56.19 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 12 panels for an 8 kW build require 402 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of SKYCELL USA SKY 725-BHDG24-USA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SKYCELL USA SKY 725-BHDG24-USA 8 kW Residential Fit

Needs 12 modules (402 sq ft) with a 30 A string OCPD, offsetting ~$2,178/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Thornova Solar TS-BGT66(725)-G12.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 691.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SKYCELL USA SKY 725-BHDG24-USA by SKYCELL USA grounded in CEC test data and NEC 690.7/690.8 limits.

Why is SKYCELL USA SKY 725-BHDG24-USA PTC wattage (691.2 W) lower than STC (725.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 691.2 W PTC (95.3% retention) across SKYCELL USA SKY 725-BHDG24-USA's 3.11 m2 aperture.

Who should skip SKYCELL USA SKY 725-BHDG24-USA on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 12 SKYCELL USA SKY 725-BHDG24-USA panels (402 sq ft) leave unusable roof gaps vs. Thornova Solar TS-BGT66(725)-G12.

What is the 1,000 V commercial string limit for SKYCELL USA SKY 725-BHDG24-USA?

On 1,000 V commercial inverters at -10 C (55.01 V cold Voc), SKYCELL USA SKY 725-BHDG24-USA fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting SKYCELL USA SKY 725-BHDG24-USA.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.