Thornova Solar TS-BGT66(730)-G12 is a 730.0 W STC (694.6 W PTC) Mono-c-Si solar module ranking #31 of 21,677 CEC listings (top 0.2%; higher than 99.8% of peers). It delivers 23.7% efficiency, 49.8 V Voc at 25 C, and 53.74 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 730.0 W
- PTC Wattage
- 694.6 W
- Voc @ 25C
- 49.8 V
- Efficiency
- 23.7%
How Does Thornova Solar TS-BGT66(730)-G12 Compare Against Peer CEC Listings?
Solar engineering breakdown for Thornova Solar TS-BGT66(730)-G12: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Thornova Solar and peers, Thornova Solar TS-BGT66(730)-G12 stands 320.0 W above the 410.0 W Mono-c-Si median and strong 95.2% PTC-to-STC heat retention (#399 of 21,677). Sizing 6 kW (9 panels) to 10 kW (14 panels) yields $1,644-$2,558/yr in baseline US bill offset. Higher 49.8 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Thornova Solar TS-BGT66(730)-G12 Fall Across Listed CEC Models?
Distribution marker showing Thornova Solar TS-BGT66(730)-G12 (730.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Thornova Solar TS-BGT66(730)-G12?
Dataset percentiles tracking Thornova Solar TS-BGT66(730)-G12 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Thornova Solar TS-BGT66(730)-G12?
Benchmark highlights for Thornova Solar TS-BGT66(730)-G12 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 0.2% STC Output
730.0 W STC (+345.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.7% Aperture Efficiency
Power density 237.0 W/m2 (3.79 percentage points above 19.91% CEC median). PTC/STC ratio: 95.2% (rank #399).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.74 V at -10 C (591.1 V string) and 54.86 V at -20 C (10 max).
11 Panels = 8,030 W STC
Occupies 33.9 m2 (365 sq ft) producing 7,641 W PTC; NEC 690.8 OCPD floor is 28.95 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.8 * (1 + (-0.226/100) * (-10 - 25)) = 53.74 V | OCPD = 1.56 * 18.56 = 28.95 A
Inputs from CEC Modules.csv for Thornova Solar TS-BGT66(730)-G12: Voc=49.8 V, beta_Voc=-0.226%/C, Isc=18.56 A, STC=730.0 W, Area=3.08 m2.
Result: 11 panels max on 600 V (591.1 V); 11 panels for 8 kW (365 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-BGT66(730)-G12?
Official CEC datasheet figures for Thornova Solar TS-BGT66(730)-G12 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 730.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 694.6 W (95.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.7 V / 17.48 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.226 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.7% (3.08 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Thornova Solar TS-BGT66(730)-G12 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Thornova Solar TS-BGT66(730)-G12 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 9 | 6.57 kW | 298 sq ft | $1,644 | $2,781 |
| 8 kW Class | 11 | 8.03 kW | 365 sq ft | $2,010 | $3,398 |
| 10 kW Class | 14 | 10.22 kW | 464 sq ft | $2,558 | $4,325 |
How Many Thornova Solar TS-BGT66(730)-G12 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Thornova Solar TS-BGT66(730)-G12 (53.74 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.86 V | 10 panels | 548.6 V | 18 panels |
| -10 C (14 F) | 53.74 V | 11 panels | 591.1 V | 18 panels |
| 0 C (32 F) | 52.61 V | 11 panels | 578.7 V | 19 panels |
| 25 C (77 F STC) | 49.8 V | 12 panels | 597.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-BGT66(730)-G12?
Competing CEC solar panels closest to Thornova Solar TS-BGT66(730)-G12 in nameplate wattage and Voc, starting with JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD132N-730.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD132N-730 JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD |
730.0 W | Tie (0 W) | 49.8 V | 23.7% | 94.5% |
| Suzhou Talesun Solar Technologies Co Ltd TM8G66M-730 Suzhou Talesun Solar Technologies Co Ltd |
730.0 W | Tie (0 W) | 49.8 V | 23.7% | 94.5% |
| Risen Energy Co Ltd RSM132-8-730BHDG Risen Energy Co Ltd |
730.0 W | Tie (0 W) | 50.33 V | 23.47% | 94.9% |
| CSI Solar Co Ltd CS7N-730TB-AG CSI Solar Co Ltd |
730.0 W | Tie (0 W) | 49.1 V | 24.09% | 94.9% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-BGT66(730)-G12?
Evaluate Thornova Solar TS-BGT66(730)-G12 (730.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-BGT66(730)-G12 reaches 54.86 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 11 panels for an 8 kW build require 365 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-BGT66(730)-G12 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-BGT66(730)-G12 8 kW Residential Fit
Needs 11 modules (365 sq ft) with a 30 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare JOLYWOOD (TAIZHOU) SOLAR TECHNOLOGY CO LTD JW-HD132N-730.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 694.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-BGT66(730)-G12 by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Thornova Solar TS-BGT66(730)-G12?
Multiplying Thornova Solar TS-BGT66(730)-G12's 18.56 A short-circuit current by 1.56 equals 28.95 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.
Can Thornova Solar TS-BGT66(730)-G12 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.74 V cold Voc at 14 F and handles 18.56 A Isc; string inverters cap Thornova Solar TS-BGT66(730)-G12 at 11 panels on 600 V.
Is Thornova Solar TS-BGT66(730)-G12 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Thornova Solar TS-BGT66(730)-G12 rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)