Thornova Solar TS-SB54(415) is a 415.0 W STC (391.4 W PTC) Mono-c-Si solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 21.39% efficiency, 37.79 V Voc at 25 C, and 40.92 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 415.0 W
- PTC Wattage
- 391.4 W
- Voc @ 25C
- 37.79 V
- Efficiency
- 21.39%
How Does Thornova Solar TS-SB54(415) Compare Against Peer CEC Listings?
How Thornova Solar Thornova Solar TS-SB54(415) handles rooftop heat (391.4 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Thornova Solar TS-SB54(415) exhibits 13.72 A short-circuit current, requiring a 21.4 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #8,199 of 21,677 (5.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 38.8 m2 for an 8 kW system (25 panels for 10 kW). Lower 37.79 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Thornova Solar TS-SB54(415) Fall Across Listed CEC Models?
Where Thornova Solar TS-SB54(415) (415.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Thornova Solar TS-SB54(415)?
Percentile placement of Thornova Solar TS-SB54(415) across power density (213.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Thornova Solar TS-SB54(415)?
Four critical engineering numbers homeowners and solar installers check first when reviewing Thornova Solar TS-SB54(415) specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Top 39.4% STC Output
415.0 W STC (+30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.39% Aperture Efficiency
Power density 213.9 W/m2 (1.48 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.92 V at -10 C (572.9 V string) and 41.82 V at -20 C (14 max).
20 Panels = 8,300 W STC
Occupies 38.8 m2 (418 sq ft) producing 7,828 W PTC; NEC 690.8 OCPD floor is 21.4 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.79 * (1 + (-0.237/100) * (-10 - 25)) = 40.92 V | OCPD = 1.56 * 13.72 = 21.4 A
Inputs from CEC Modules.csv for Thornova Solar TS-SB54(415): Voc=37.79 V, beta_Voc=-0.237%/C, Isc=13.72 A, STC=415.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (572.9 V); 20 panels for 8 kW (418 sq ft).
What Are the Published CEC Specifications for Thornova Solar TS-SB54(415)?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Thornova Solar TS-SB54(415).
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 391.4 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.79 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.72 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.94 V / 13.0 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.237 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.39% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Thornova Solar TS-SB54(415) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Thornova Solar TS-SB54(415) (415.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.22 kW | 313 sq ft | $1,557 | $2,632 |
| 8 kW Class | 20 | 8.3 kW | 418 sq ft | $2,077 | $3,513 |
| 10 kW Class | 25 | 10.38 kW | 522 sq ft | $2,598 | $4,393 |
How Many Thornova Solar TS-SB54(415) Modules Fit in a Cold-Weather String?
Maximum series module counts for Thornova Solar TS-SB54(415) from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.82 V | 14 panels | 585.5 V | 23 panels |
| -10 C (14 F) | 40.92 V | 14 panels | 572.9 V | 24 panels |
| 0 C (32 F) | 40.03 V | 14 panels | 560.4 V | 24 panels |
| 25 C (77 F STC) | 37.79 V | 15 panels | 566.9 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Thornova Solar TS-SB54(415)?
Alternative CEC solar modules from competing brands near Thornova Solar TS-SB54(415) (415.0 W), including Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a Aptos Solar Technology LLC |
415.0 W | Tie (0 W) | 37.7 V | 21.39% | 93.0% |
| AXITEC AC-415TGB/108BB AXITEC |
415.0 W | Tie (0 W) | 38.04 V | 21.84% | 94.9% |
| Aptos Solar Technology LLC DNA-108-BF10-415W Aptos Solar Technology LLC |
415.0 W | Tie (0 W) | 37.5 V | 21.28% | 94.3% |
| AXITEC AC-415MH/108V AXITEC |
415.0 W | Tie (0 W) | 37.38 V | 21.5% | 92.7% |
What Are the Design Limits and Best-Fit Uses for Thornova Solar TS-SB54(415)?
Evaluate Thornova Solar TS-SB54(415) (415.0 W STC, 37.79 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Thornova Solar TS-SB54(415) reaches 41.82 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Thornova Solar TS-SB54(415) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Thornova Solar TS-SB54(415) 8 kW Residential Fit
Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,077/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 391.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Thornova Solar TS-SB54(415) by Thornova Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Thornova Solar TS-SB54(415) PTC wattage (391.4 W) lower than STC (415.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 391.4 W PTC (94.3% retention) across Thornova Solar TS-SB54(415)'s 1.94 m2 aperture.
Who should skip Thornova Solar TS-SB54(415) on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 Thornova Solar TS-SB54(415) panels (418 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-108-MF10-415W-USAptos1a.
What is the 1,000 V commercial string limit for Thornova Solar TS-SB54(415)?
On 1,000 V commercial inverters at -10 C (40.92 V cold Voc), Thornova Solar TS-SB54(415) fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Thornova Solar TS-SB54(415).
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)