Shanghai ST Solar STP260-72 is a 260.0 W STC (232.4 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 13.22% efficiency, 43.2 V Voc at 25 C, and 48.04 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 232.4 W
- Voc @ 25C
- 43.2 V
- Efficiency
- 13.22%
How Does Shanghai ST Solar STP260-72 Compare Against Peer CEC Listings?
Solar engineering breakdown for Shanghai ST Solar STP260-72: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Shanghai ST Solar and peers, Shanghai ST Solar STP260-72 stands 18.8 W below the 278.8 W Multi-c-Si median and typical 89.4% PTC-to-STC thermal output (232.4 W real-world rating). Sizing 6 kW (24 panels) to 10 kW (39 panels) yields $1,562-$2,538/yr in baseline US bill offset. Mid-range 43.2 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does Shanghai ST Solar STP260-72 Fall Across Listed CEC Models?
Distribution marker showing Shanghai ST Solar STP260-72 (260.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Shanghai ST Solar STP260-72?
Dataset percentiles tracking Shanghai ST Solar STP260-72 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Shanghai ST Solar STP260-72?
Benchmark highlights for Shanghai ST Solar STP260-72 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
13.22% Aperture Efficiency
Power density 132.2 W/m2 (6.69 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 48.04 V at -10 C (576.5 V string) and 49.42 V at -20 C (12 max).
31 Panels = 8,060 W STC
Occupies 60.9 m2 (656 sq ft) producing 7,204 W PTC; NEC 690.8 OCPD floor is 13.04 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.2 * (1 + (-0.32/100) * (-10 - 25)) = 48.04 V | OCPD = 1.56 * 8.36 = 13.04 A
Inputs from CEC Modules.csv for Shanghai ST Solar STP260-72: Voc=43.2 V, beta_Voc=-0.32%/C, Isc=8.36 A, STC=260.0 W, Area=1.966 m2.
Result: 12 panels max on 600 V (576.5 V); 31 panels for 8 kW (656 sq ft).
What Are the Published CEC Specifications for Shanghai ST Solar STP260-72?
Official CEC datasheet figures for Shanghai ST Solar STP260-72 (Multi-c-Si) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 232.4 W (89.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.36 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.56 V / 7.52 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.32 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 13.22% (1.966 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Shanghai ST Solar STP260-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Shanghai ST Solar STP260-72 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 508 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 656 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 825 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Shanghai ST Solar Series?
Consolidated Shanghai ST Solar wattage variants sharing the Shanghai ST Solar STP260-72 mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Shanghai ST Solar STP250-72 | 250.0 W | 223.3 W | 43.2 V | 34.56 V | 12.72% |
| Shanghai ST Solar STP255-72 | 255.0 W | 227.8 W | 43.2 V | 34.56 V | 12.97% |
| Shanghai ST Solar STP260-72 | 260.0 W | 232.4 W | 43.2 V | 34.56 V | 13.22% |
| Shanghai ST Solar STP265-72 | 265.0 W | 237.0 W | 44.1 V | 35.28 V | 13.48% |
| Shanghai ST Solar STP270-72 | 270.0 W | 241.6 W | 44.1 V | 35.28 V | 13.73% |
How Many Shanghai ST Solar STP260-72 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Shanghai ST Solar STP260-72 (48.04 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 49.42 V | 12 panels | 593.0 V | 20 panels |
| -10 C (14 F) | 48.04 V | 12 panels | 576.5 V | 20 panels |
| 0 C (32 F) | 46.66 V | 12 panels | 559.9 V | 21 panels |
| 25 C (77 F STC) | 43.2 V | 13 panels | 561.6 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to Shanghai ST Solar STP260-72?
Competing CEC solar panels closest to Shanghai ST Solar STP260-72 in nameplate wattage and Voc, starting with Gintung Energy ASEC-260G6M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-260G6M Gintung Energy |
260.0 W | Tie (0 W) | 43.84 V | 13.29% | 89.3% |
| Advance Power API-P265 Advance Power |
265.0 W | +5.0 W | 43.27 V | 13.58% | 89.1% |
| Auxin Solar AXN6P610T265 Auxin Solar |
265.0 W | +5.0 W | 43.27 V | 13.58% | 89.1% |
| BYD Company Limited BYD 265P6C-36 BYD Company Limited |
265.0 W | +5.0 W | 43.11 V | 13.66% | 90.9% |
What Are the Design Limits and Best-Fit Uses for Shanghai ST Solar STP260-72?
Evaluate Shanghai ST Solar STP260-72 (260.0 W STC, 43.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Shanghai ST Solar STP260-72 reaches 49.42 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 656 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (656 sq ft).
- 2026 tax credit baseline: cash residential installs of Shanghai ST Solar STP260-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Shanghai ST Solar STP260-72 8 kW Residential Fit
Needs 31 modules (656 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Gintung Energy ASEC-260G6M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 232.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Shanghai ST Solar STP260-72 by Shanghai ST Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Shanghai ST Solar STP260-72?
Multiplying Shanghai ST Solar STP260-72's 8.36 A short-circuit current by 1.56 equals 13.04 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Shanghai ST Solar STP260-72 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 48.04 V cold Voc at 14 F and handles 8.36 A Isc; string inverters cap Shanghai ST Solar STP260-72 at 12 panels on 600 V.
Is Shanghai ST Solar STP260-72 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Shanghai ST Solar STP260-72 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)