Skip to main content
WireAndSun
Calculators
CEC PV Module

Shanghai ST Solar STP260-72 — CEC Solar Module Specifications

Manufacturer: Shanghai ST Solar Registry: CEC Verified Engineering Specification

Shanghai ST Solar STP260-72 is a 260.0 W STC (232.4 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 13.22% efficiency, 43.2 V Voc at 25 C, and 48.04 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
232.4 W
Voc @ 25C
43.2 V
Efficiency
13.22%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shanghai ST Solar STP260-72 Compare Against Peer CEC Listings?

Solar engineering breakdown for Shanghai ST Solar STP260-72: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Shanghai ST Solar and peers, Shanghai ST Solar STP260-72 stands 18.8 W below the 278.8 W Multi-c-Si median and typical 89.4% PTC-to-STC thermal output (232.4 W real-world rating). Sizing 6 kW (24 panels) to 10 kW (39 panels) yields $1,562-$2,538/yr in baseline US bill offset. Mid-range 43.2 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Shanghai ST Solar STP260-72 Fall Across Listed CEC Models?

Distribution marker showing Shanghai ST Solar STP260-72 (260.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Shanghai ST Solar STP260-72 (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCShanghai ST Solar : 260.0 W

What Dataset Percentiles Define Shanghai ST Solar STP260-72?

Dataset percentiles tracking Shanghai ST Solar STP260-72 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Shanghai ST Solar STP260-72 Engineering BenchmarksPercentile comparison of Shanghai ST Solar STP260-72 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention89.4%Module Efficiency13.22%

What Do the Dataset Ranks Show for Shanghai ST Solar STP260-72?

Benchmark highlights for Shanghai ST Solar STP260-72 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,345

13.22% Aperture Efficiency

Power density 132.2 W/m2 (6.69 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.04 V at -10 C (576.5 V string) and 49.42 V at -20 C (12 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 60.9 m2 (656 sq ft) producing 7,204 W PTC; NEC 690.8 OCPD floor is 13.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.2 * (1 + (-0.32/100) * (-10 - 25)) = 48.04 V | OCPD = 1.56 * 8.36 = 13.04 A

Inputs from CEC Modules.csv for Shanghai ST Solar STP260-72: Voc=43.2 V, beta_Voc=-0.32%/C, Isc=8.36 A, STC=260.0 W, Area=1.966 m2.

Result: 12 panels max on 600 V (576.5 V); 31 panels for 8 kW (656 sq ft).

What Are the Published CEC Specifications for Shanghai ST Solar STP260-72?

Official CEC datasheet figures for Shanghai ST Solar STP260-72 (Multi-c-Si) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Official California Energy Commission (NREL SAM) test parameters for Shanghai ST Solar STP260-72.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 232.4 W (89.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.36 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.56 V / 7.52 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.32 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.22% (1.966 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Shanghai ST Solar STP260-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Shanghai ST Solar STP260-72 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 508 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 656 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 825 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Shanghai ST Solar Series?

Consolidated Shanghai ST Solar wattage variants sharing the Shanghai ST Solar STP260-72 mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Shanghai ST Solar STP260-72 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Shanghai ST Solar STP250-72 250.0 W 223.3 W 43.2 V 34.56 V 12.72%
Shanghai ST Solar STP255-72 255.0 W 227.8 W 43.2 V 34.56 V 12.97%
Shanghai ST Solar STP260-72 260.0 W 232.4 W 43.2 V 34.56 V 13.22%
Shanghai ST Solar STP265-72 265.0 W 237.0 W 44.1 V 35.28 V 13.48%
Shanghai ST Solar STP270-72 270.0 W 241.6 W 44.1 V 35.28 V 13.73%

How Many Shanghai ST Solar STP260-72 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Shanghai ST Solar STP260-72 (48.04 V at 14 F).

Computed from Voc=43.2V and beta_Voc=-0.32%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.42 V 12 panels 593.0 V 20 panels
-10 C (14 F) 48.04 V 12 panels 576.5 V 20 panels
0 C (32 F) 46.66 V 12 panels 559.9 V 21 panels
25 C (77 F STC) 43.2 V 13 panels 561.6 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Shanghai ST Solar STP260-72?

Competing CEC solar panels closest to Shanghai ST Solar STP260-72 in nameplate wattage and Voc, starting with Gintung Energy ASEC-260G6M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-260G6M
Gintung Energy
260.0 W Tie (0 W) 43.84 V 13.29% 89.3%
Advance Power API-P265
Advance Power
265.0 W +5.0 W 43.27 V 13.58% 89.1%
Auxin Solar AXN6P610T265
Auxin Solar
265.0 W +5.0 W 43.27 V 13.58% 89.1%
BYD Company Limited BYD 265P6C-36
BYD Company Limited
265.0 W +5.0 W 43.11 V 13.66% 90.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Shanghai ST Solar STP260-72?

Evaluate Shanghai ST Solar STP260-72 (260.0 W STC, 43.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Shanghai ST Solar STP260-72 reaches 49.42 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 656 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (656 sq ft).
  • 2026 tax credit baseline: cash residential installs of Shanghai ST Solar STP260-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Shanghai ST Solar STP260-72 8 kW Residential Fit

Needs 31 modules (656 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Gintung Energy ASEC-260G6M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 232.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Shanghai ST Solar STP260-72 by Shanghai ST Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Shanghai ST Solar STP260-72?

Multiplying Shanghai ST Solar STP260-72's 8.36 A short-circuit current by 1.56 equals 13.04 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Shanghai ST Solar STP260-72 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 48.04 V cold Voc at 14 F and handles 8.36 A Isc; string inverters cap Shanghai ST Solar STP260-72 at 12 panels on 600 V.

Is Shanghai ST Solar STP260-72 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Shanghai ST Solar STP260-72 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.