Skip to main content
WireAndSun
Calculators
CEC PV Module

Shanghai ST Solar STP300-72 — CEC Solar Module Specifications

Manufacturer: Shanghai ST Solar Registry: CEC Verified Engineering Specification

Shanghai ST Solar STP300-72 is a 300.0 W STC (269.2 W PTC) Multi-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 15.26% efficiency, 45.0 V Voc at 25 C, and 50.04 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
300.0 W
PTC Wattage
269.2 W
Voc @ 25C
45.0 V
Efficiency
15.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shanghai ST Solar STP300-72 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Shanghai ST Solar STP300-72 (Multi-c-Si) residential solar systems.

Homeowners evaluating Shanghai ST Solar STP300-72 need 20 panels for 6 kW or 27 panels (571 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (571 sq ft). Under NEC 690.7(A), beta_Voc (-0.32%/C) pushes open-circuit voltage to 50.04 V at 14 F and 51.48 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Shanghai ST Solar STP300-72 Fall Across Listed CEC Models?

Comparison of Shanghai ST Solar STP300-72 (300.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Shanghai ST Solar STP300-72 (300.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCShanghai ST Solar : 300.0 W

What Dataset Percentiles Define Shanghai ST Solar STP300-72?

Relative ranking of Shanghai ST Solar STP300-72 across nameplate watts, 89.7% PTC thermal ratio, and module aperture efficiency.

Shanghai ST Solar STP300-72 Engineering BenchmarksPercentile comparison of Shanghai ST Solar STP300-72 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage300.0 WPTC/STC Retention89.7%Module Efficiency15.26%

What Do the Dataset Ranks Show for Shanghai ST Solar STP300-72?

Summary of Shanghai ST Solar STP300-72 output rank, 8 kW array size (27 panels), efficiency rating, and 600 V string limit.

Rank #16,498 / 21,677

300.0 W STC · Higher Than 22.1%

300.0 W STC (-85.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,351

15.26% Aperture Efficiency

Power density 152.6 W/m2 (4.65 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.04 V at -10 C (550.4 V string) and 51.48 V at -20 C (11 max).

8 kW Reference Array

27 Panels = 8,100 W STC

Occupies 53.1 m2 (571 sq ft) producing 7,268 W PTC; NEC 690.8 OCPD floor is 14.45 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.0 * (1 + (-0.32/100) * (-10 - 25)) = 50.04 V | OCPD = 1.56 * 9.26 = 14.45 A

Inputs from CEC Modules.csv for Shanghai ST Solar STP300-72: Voc=45.0 V, beta_Voc=-0.32%/C, Isc=9.26 A, STC=300.0 W, Area=1.966 m2.

Result: 11 panels max on 600 V (550.4 V); 27 panels for 8 kW (571 sq ft).

What Are the Published CEC Specifications for Shanghai ST Solar STP300-72?

Complete CEC test sheet for Shanghai ST Solar STP300-72 including Isc (9.26 A), Voc (45.0 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Shanghai ST Solar STP300-72.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 300.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 269.2 W (89.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.26 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.0 V / 8.33 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.32 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.26% (1.966 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Shanghai ST Solar STP300-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Shanghai ST Solar STP300-72.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.0 kW 423 sq ft $1,502 $2,539
8 kW Class 27 8.1 kW 571 sq ft $2,027 $3,428
10 kW Class 34 10.2 kW 720 sq ft $2,553 $4,317

How Many Shanghai ST Solar STP300-72 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Shanghai ST Solar STP300-72 (45.0 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.0V and beta_Voc=-0.32%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.48 V 11 panels 566.3 V 19 panels
-10 C (14 F) 50.04 V 11 panels 550.4 V 19 panels
0 C (32 F) 48.6 V 12 panels 583.2 V 20 panels
25 C (77 F STC) 45.0 V 13 panels 585.0 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Shanghai ST Solar STP300-72?

Four comparable CEC modules such as Auxin Solar AXN6P612T305G (305.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6P612T305G
Auxin Solar
305.0 W +5.0 W 45.0 V 15.63% 90.3%
Auxin Solar AXN6M612T310
Auxin Solar
310.0 W +10.0 W 45.0 V 15.89% 89.4%
AXITEC AC-310P/156-72S
AXITEC
310.0 W +10.0 W 45.05 V 16.01% 89.0%
CSI Solar Co Ltd CS6X-310P
CSI Solar Co Ltd
310.0 W +10.0 W 44.9 V 16.31% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Shanghai ST Solar STP300-72?

Evaluate Shanghai ST Solar STP300-72 (300.0 W STC, 45.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Shanghai ST Solar STP300-72 reaches 51.48 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 571 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (571 sq ft).
  • 2026 tax credit baseline: cash residential installs of Shanghai ST Solar STP300-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Shanghai ST Solar STP300-72 8 kW Residential Fit

Needs 27 modules (571 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 269.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Shanghai ST Solar STP300-72 by Shanghai ST Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Shanghai ST Solar STP300-72 PTC wattage (269.2 W) lower than STC (300.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 269.2 W PTC (89.7% retention) across Shanghai ST Solar STP300-72's 1.966 m2 aperture.

Who should skip Shanghai ST Solar STP300-72 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 27 Shanghai ST Solar STP300-72 panels (571 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6P612T305G.

What is the 1,000 V commercial string limit for Shanghai ST Solar STP300-72?

On 1,000 V commercial inverters at -10 C (50.04 V cold Voc), Shanghai ST Solar STP300-72 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Shanghai ST Solar STP300-72.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.