Shanghai ST Solar STP300-72 is a 300.0 W STC (269.2 W PTC) Multi-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 15.26% efficiency, 45.0 V Voc at 25 C, and 50.04 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 300.0 W
- PTC Wattage
- 269.2 W
- Voc @ 25C
- 45.0 V
- Efficiency
- 15.26%
How Does Shanghai ST Solar STP300-72 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Shanghai ST Solar STP300-72 (Multi-c-Si) residential solar systems.
Homeowners evaluating Shanghai ST Solar STP300-72 need 20 panels for 6 kW or 27 panels (571 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (571 sq ft). Under NEC 690.7(A), beta_Voc (-0.32%/C) pushes open-circuit voltage to 50.04 V at 14 F and 51.48 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Shanghai ST Solar STP300-72 Fall Across Listed CEC Models?
Comparison of Shanghai ST Solar STP300-72 (300.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Shanghai ST Solar STP300-72?
Relative ranking of Shanghai ST Solar STP300-72 across nameplate watts, 89.7% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Shanghai ST Solar STP300-72?
Summary of Shanghai ST Solar STP300-72 output rank, 8 kW array size (27 panels), efficiency rating, and 600 V string limit.
300.0 W STC · Higher Than 22.1%
300.0 W STC (-85.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.26% Aperture Efficiency
Power density 152.6 W/m2 (4.65 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.04 V at -10 C (550.4 V string) and 51.48 V at -20 C (11 max).
27 Panels = 8,100 W STC
Occupies 53.1 m2 (571 sq ft) producing 7,268 W PTC; NEC 690.8 OCPD floor is 14.45 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.0 * (1 + (-0.32/100) * (-10 - 25)) = 50.04 V | OCPD = 1.56 * 9.26 = 14.45 A
Inputs from CEC Modules.csv for Shanghai ST Solar STP300-72: Voc=45.0 V, beta_Voc=-0.32%/C, Isc=9.26 A, STC=300.0 W, Area=1.966 m2.
Result: 11 panels max on 600 V (550.4 V); 27 panels for 8 kW (571 sq ft).
What Are the Published CEC Specifications for Shanghai ST Solar STP300-72?
Complete CEC test sheet for Shanghai ST Solar STP300-72 including Isc (9.26 A), Voc (45.0 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 269.2 W (89.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.26 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.0 V / 8.33 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.32 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.26% (1.966 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Shanghai ST Solar STP300-72 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Shanghai ST Solar STP300-72.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.0 kW | 423 sq ft | $1,502 | $2,539 |
| 8 kW Class | 27 | 8.1 kW | 571 sq ft | $2,027 | $3,428 |
| 10 kW Class | 34 | 10.2 kW | 720 sq ft | $2,553 | $4,317 |
How Many Shanghai ST Solar STP300-72 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Shanghai ST Solar STP300-72 (45.0 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.48 V | 11 panels | 566.3 V | 19 panels |
| -10 C (14 F) | 50.04 V | 11 panels | 550.4 V | 19 panels |
| 0 C (32 F) | 48.6 V | 12 panels | 583.2 V | 20 panels |
| 25 C (77 F STC) | 45.0 V | 13 panels | 585.0 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Shanghai ST Solar STP300-72?
Four comparable CEC modules such as Auxin Solar AXN6P612T305G (305.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6P612T305G Auxin Solar |
305.0 W | +5.0 W | 45.0 V | 15.63% | 90.3% |
| Auxin Solar AXN6M612T310 Auxin Solar |
310.0 W | +10.0 W | 45.0 V | 15.89% | 89.4% |
| AXITEC AC-310P/156-72S AXITEC |
310.0 W | +10.0 W | 45.05 V | 16.01% | 89.0% |
| CSI Solar Co Ltd CS6X-310P CSI Solar Co Ltd |
310.0 W | +10.0 W | 44.9 V | 16.31% | 91.4% |
What Are the Design Limits and Best-Fit Uses for Shanghai ST Solar STP300-72?
Evaluate Shanghai ST Solar STP300-72 (300.0 W STC, 45.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Shanghai ST Solar STP300-72 reaches 51.48 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 571 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (571 sq ft).
- 2026 tax credit baseline: cash residential installs of Shanghai ST Solar STP300-72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Shanghai ST Solar STP300-72 8 kW Residential Fit
Needs 27 modules (571 sq ft) with a 15 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 269.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Shanghai ST Solar STP300-72 by Shanghai ST Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Shanghai ST Solar STP300-72 PTC wattage (269.2 W) lower than STC (300.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 269.2 W PTC (89.7% retention) across Shanghai ST Solar STP300-72's 1.966 m2 aperture.
Who should skip Shanghai ST Solar STP300-72 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 27 Shanghai ST Solar STP300-72 panels (571 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6P612T305G.
What is the 1,000 V commercial string limit for Shanghai ST Solar STP300-72?
On 1,000 V commercial inverters at -10 C (50.04 V cold Voc), Shanghai ST Solar STP300-72 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Shanghai ST Solar STP300-72.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)