Shanghai ST Solar STM280-104 — CEC Solar Module Specifications

Manufacturer: Shanghai ST Solar Registry: CEC Verified Engineering Specification

Shanghai ST Solar STM280-104 is a 280.0 W STC (250.2 W PTC) Mono-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 15.29% efficiency, 65.0 V Voc at 25 C, and 72.73 V cold Voc at -10 C (8 panels max per 600 V string).

STC Wattage
280.0 W
PTC Wattage
250.2 W
Voc @ 25C
65.0 V
Efficiency
15.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shanghai ST Solar STM280-104 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Shanghai ST Solar STM280-104 (Mono-c-Si) residential solar systems.

Homeowners evaluating Shanghai ST Solar STM280-104 need 22 panels for 6 kW or 29 panels (572 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (572 sq ft). Under NEC 690.7(A), beta_Voc (-0.34%/C) pushes open-circuit voltage to 72.73 V at 14 F and 74.95 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Shanghai ST Solar STM280-104 Fall Across Listed CEC Models?

Comparison of Shanghai ST Solar STM280-104 (280.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Shanghai ST Solar STM280-104 (280.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCShanghai ST Solar : 280.0 W

What Dataset Percentiles Define Shanghai ST Solar STM280-104?

Relative ranking of Shanghai ST Solar STM280-104 across nameplate watts, 89.4% PTC thermal ratio, and module aperture efficiency.

Shanghai ST Solar STM280-104 Engineering BenchmarksPercentile comparison of Shanghai ST Solar STM280-104 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage280.0 WPTC/STC Retention89.4%Module Efficiency15.29%

What Do the Dataset Ranks Show for Shanghai ST Solar STM280-104?

Summary of Shanghai ST Solar STM280-104 output rank, 8 kW array size (29 panels), efficiency rating, and 600 V string limit.

Rank #17,941 / 21,677

280.0 W STC · Higher Than 15.8%

280.0 W STC (-105.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,272

15.29% Aperture Efficiency

Power density 152.8 W/m2 (4.62 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).

NEC 690.7 Limit

8 Panels Max @ -10 C (600 V)

Cold Voc reaches 72.73 V at -10 C (581.8 V string) and 74.95 V at -20 C (8 max).

8 kW Reference Array

29 Panels = 8,120 W STC

Occupies 53.1 m2 (572 sq ft) producing 7,256 W PTC; NEC 690.8 OCPD floor is 9.33 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 65.0 * (1 + (-0.34/100) * (-10 - 25)) = 72.73 V | OCPD = 1.56 * 5.98 = 9.33 A

Inputs from CEC Modules.csv for Shanghai ST Solar STM280-104: Voc=65.0 V, beta_Voc=-0.34%/C, Isc=5.98 A, STC=280.0 W, Area=1.832 m2.

Result: 8 panels max on 600 V (581.8 V); 29 panels for 8 kW (572 sq ft).

What Are the Published CEC Specifications for Shanghai ST Solar STM280-104?

Complete CEC test sheet for Shanghai ST Solar STM280-104 including Isc (5.98 A), Voc (65.0 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Shanghai ST Solar STM280-104.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 280.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 250.2 W (89.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 65.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.98 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 52.0 V / 5.38 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.34 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.29% (1.832 m2) Array roof footprint density
Cell Count & Technology 104 cells (Mono-c-Si) Monofacial backsheet

How Many Shanghai ST Solar STM280-104 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Shanghai ST Solar STM280-104.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.16 kW 434 sq ft $1,542 $2,607
8 kW Class 29 8.12 kW 572 sq ft $2,032 $3,437
10 kW Class 36 10.08 kW 710 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Shanghai ST Solar Series?

Related Shanghai ST Solar power steps and black/silver trims consolidated into this Shanghai ST Solar STM280-104 series guide.

Sibling CEC listings grouped into the Shanghai ST Solar STM280-104 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Shanghai ST Solar STM275-104 275.0 W 245.6 W 65.0 V 52.0 V 15.01%
Shanghai ST Solar STM280-104 280.0 W 250.2 W 65.0 V 52.0 V 15.29%
Shanghai ST Solar STM285-104 285.0 W 254.8 W 65.0 V 52.0 V 15.56%

How Many Shanghai ST Solar STM280-104 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Shanghai ST Solar STM280-104 (65.0 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=65.0V and beta_Voc=-0.34%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 74.95 V 8 panels 599.6 V 13 panels
-10 C (14 F) 72.73 V 8 panels 581.8 V 13 panels
0 C (32 F) 70.52 V 8 panels 564.2 V 14 panels
25 C (77 F STC) 65.0 V 9 panels 585.0 V 15 panels

Which Cross-Brand Solar Modules Compare Closest to Shanghai ST Solar STM280-104?

Four comparable CEC modules such as Gintung Energy ASEC-285G6S (285.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-285G6S
Gintung Energy
285.0 W +5.0 W 44.69 V 14.57% 89.7%
Gintung Energy ASEC-285G6M
Gintung Energy
285.0 W +5.0 W 44.53 V 14.57% 89.5%
AXITEC AC-285P/156-72S
AXITEC
285.0 W +5.0 W 44.51 V 14.72% 90.0%
Centrosolar America DP72 285
Centrosolar America
285.0 W +5.0 W 44.32 V 14.66% 88.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Shanghai ST Solar STM280-104?

Evaluate Shanghai ST Solar STM280-104 (280.0 W STC, 65.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Shanghai ST Solar STM280-104 reaches 74.95 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 572 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (572 sq ft).
  • 2026 tax credit baseline: cash residential installs of Shanghai ST Solar STM280-104 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Shanghai ST Solar STM280-104 8 kW Residential Fit

Needs 29 modules (572 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Gintung Energy ASEC-285G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 250.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Shanghai ST Solar STM280-104 by Shanghai ST Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Shanghai ST Solar STM280-104 PTC wattage (250.2 W) lower than STC (280.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 250.2 W PTC (89.4% retention) across Shanghai ST Solar STM280-104's 1.832 m2 aperture.

Who should skip Shanghai ST Solar STM280-104 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 Shanghai ST Solar STM280-104 panels (572 sq ft) leave unusable roof gaps vs. Gintung Energy ASEC-285G6S.

What is the 1,000 V commercial string limit for Shanghai ST Solar STM280-104?

On 1,000 V commercial inverters at -10 C (72.73 V cold Voc), Shanghai ST Solar STM280-104 fits up to 13 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Shanghai ST Solar STM280-104.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.