Shanghai ST Solar STM280-104 is a 280.0 W STC (250.2 W PTC) Mono-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 15.29% efficiency, 65.0 V Voc at 25 C, and 72.73 V cold Voc at -10 C (8 panels max per 600 V string).
- STC Wattage
- 280.0 W
- PTC Wattage
- 250.2 W
- Voc @ 25C
- 65.0 V
- Efficiency
- 15.29%
How Does Shanghai ST Solar STM280-104 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Shanghai ST Solar STM280-104 (Mono-c-Si) residential solar systems.
Homeowners evaluating Shanghai ST Solar STM280-104 need 22 panels for 6 kW or 29 panels (572 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (572 sq ft). Under NEC 690.7(A), beta_Voc (-0.34%/C) pushes open-circuit voltage to 72.73 V at 14 F and 74.95 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Shanghai ST Solar STM280-104 Fall Across Listed CEC Models?
Comparison of Shanghai ST Solar STM280-104 (280.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Shanghai ST Solar STM280-104?
Relative ranking of Shanghai ST Solar STM280-104 across nameplate watts, 89.4% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Shanghai ST Solar STM280-104?
Summary of Shanghai ST Solar STM280-104 output rank, 8 kW array size (29 panels), efficiency rating, and 600 V string limit.
280.0 W STC · Higher Than 15.8%
280.0 W STC (-105.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.29% Aperture Efficiency
Power density 152.8 W/m2 (4.62 percentage points below 19.91% CEC median). PTC/STC ratio: 89.4% (rank #20,078).
8 Panels Max @ -10 C (600 V)
Cold Voc reaches 72.73 V at -10 C (581.8 V string) and 74.95 V at -20 C (8 max).
29 Panels = 8,120 W STC
Occupies 53.1 m2 (572 sq ft) producing 7,256 W PTC; NEC 690.8 OCPD floor is 9.33 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 65.0 * (1 + (-0.34/100) * (-10 - 25)) = 72.73 V | OCPD = 1.56 * 5.98 = 9.33 A
Inputs from CEC Modules.csv for Shanghai ST Solar STM280-104: Voc=65.0 V, beta_Voc=-0.34%/C, Isc=5.98 A, STC=280.0 W, Area=1.832 m2.
Result: 8 panels max on 600 V (581.8 V); 29 panels for 8 kW (572 sq ft).
What Are the Published CEC Specifications for Shanghai ST Solar STM280-104?
Complete CEC test sheet for Shanghai ST Solar STM280-104 including Isc (5.98 A), Voc (65.0 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 280.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 250.2 W (89.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 65.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 5.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 52.0 V / 5.38 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.29% (1.832 m2) | Array roof footprint density |
| Cell Count & Technology | 104 cells (Mono-c-Si) | Monofacial backsheet |
How Many Shanghai ST Solar STM280-104 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Shanghai ST Solar STM280-104.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.16 kW | 434 sq ft | $1,542 | $2,607 |
| 8 kW Class | 29 | 8.12 kW | 572 sq ft | $2,032 | $3,437 |
| 10 kW Class | 36 | 10.08 kW | 710 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Shanghai ST Solar Series?
Related Shanghai ST Solar power steps and black/silver trims consolidated into this Shanghai ST Solar STM280-104 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Shanghai ST Solar STM275-104 | 275.0 W | 245.6 W | 65.0 V | 52.0 V | 15.01% |
| Shanghai ST Solar STM280-104 | 280.0 W | 250.2 W | 65.0 V | 52.0 V | 15.29% |
| Shanghai ST Solar STM285-104 | 285.0 W | 254.8 W | 65.0 V | 52.0 V | 15.56% |
How Many Shanghai ST Solar STM280-104 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Shanghai ST Solar STM280-104 (65.0 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 74.95 V | 8 panels | 599.6 V | 13 panels |
| -10 C (14 F) | 72.73 V | 8 panels | 581.8 V | 13 panels |
| 0 C (32 F) | 70.52 V | 8 panels | 564.2 V | 14 panels |
| 25 C (77 F STC) | 65.0 V | 9 panels | 585.0 V | 15 panels |
Which Cross-Brand Solar Modules Compare Closest to Shanghai ST Solar STM280-104?
Four comparable CEC modules such as Gintung Energy ASEC-285G6S (285.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gintung Energy ASEC-285G6S Gintung Energy |
285.0 W | +5.0 W | 44.69 V | 14.57% | 89.7% |
| Gintung Energy ASEC-285G6M Gintung Energy |
285.0 W | +5.0 W | 44.53 V | 14.57% | 89.5% |
| AXITEC AC-285P/156-72S AXITEC |
285.0 W | +5.0 W | 44.51 V | 14.72% | 90.0% |
| Centrosolar America DP72 285 Centrosolar America |
285.0 W | +5.0 W | 44.32 V | 14.66% | 88.5% |
What Are the Design Limits and Best-Fit Uses for Shanghai ST Solar STM280-104?
Evaluate Shanghai ST Solar STM280-104 (280.0 W STC, 65.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Shanghai ST Solar STM280-104 reaches 74.95 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 572 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (572 sq ft).
- 2026 tax credit baseline: cash residential installs of Shanghai ST Solar STM280-104 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Shanghai ST Solar STM280-104 8 kW Residential Fit
Needs 29 modules (572 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Gintung Energy ASEC-285G6S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 250.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Shanghai ST Solar STM280-104 by Shanghai ST Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Shanghai ST Solar STM280-104 PTC wattage (250.2 W) lower than STC (280.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 250.2 W PTC (89.4% retention) across Shanghai ST Solar STM280-104's 1.832 m2 aperture.
Who should skip Shanghai ST Solar STM280-104 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 Shanghai ST Solar STM280-104 panels (572 sq ft) leave unusable roof gaps vs. Gintung Energy ASEC-285G6S.
What is the 1,000 V commercial string limit for Shanghai ST Solar STM280-104?
On 1,000 V commercial inverters at -10 C (72.73 V cold Voc), Shanghai ST Solar STM280-104 fits up to 13 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Shanghai ST Solar STM280-104.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)