Skip to main content
WireAndSun
Calculators
CEC PV Module

AXITEC AC-285P/156-72S — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-285P/156-72S is a 285.0 W STC (256.6 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 14.72% efficiency, 44.51 V Voc at 25 C, and 49.95 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
256.6 W
Voc @ 25C
44.51 V
Efficiency
14.72%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-285P/156-72S Compare Against Peer CEC Listings?

How AXITEC AXITEC AC-285P/156-72S handles rooftop heat (256.6 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, AXITEC AC-285P/156-72S exhibits 8.52 A short-circuit current, requiring a 13.29 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #17,598 of 21,677 (6.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 56.1 m2 for an 8 kW system (36 panels for 10 kW). Mid-range 44.51 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does AXITEC AC-285P/156-72S Fall Across Listed CEC Models?

Where AXITEC AC-285P/156-72S (285.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-285P/156-72S (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-285P/156: 285.0 W

What Dataset Percentiles Define AXITEC AC-285P/156-72S?

Percentile placement of AXITEC AC-285P/156-72S across power density (147.2 W/m2), thermal retention, and nameplate STC wattage.

AXITEC AC-285P/156-72S Engineering BenchmarksPercentile comparison of AXITEC AC-285P/156-72S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention90.0%Module Efficiency14.72%

What Do the Dataset Ranks Show for AXITEC AC-285P/156-72S?

Four critical engineering numbers homeowners and solar installers check first when reviewing AXITEC AC-285P/156-72S specifications. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,142

14.72% Aperture Efficiency

Power density 147.2 W/m2 (5.19 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.95 V at -10 C (599.4 V string) and 51.5 V at -20 C (11 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 56.1 m2 (604 sq ft) producing 7,441 W PTC; NEC 690.8 OCPD floor is 13.29 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.51 * (1 + (-0.349/100) * (-10 - 25)) = 49.95 V | OCPD = 1.56 * 8.52 = 13.29 A

Inputs from CEC Modules.csv for AXITEC AC-285P/156-72S: Voc=44.51 V, beta_Voc=-0.349%/C, Isc=8.52 A, STC=285.0 W, Area=1.936 m2.

Result: 12 panels max on 600 V (599.4 V); 29 panels for 8 kW (604 sq ft).

What Are the Published CEC Specifications for AXITEC AC-285P/156-72S?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AXITEC AC-285P/156-72S.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-285P/156-72S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 256.6 W (90.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.51 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.52 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.6 V / 8.0 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.349 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.72% (1.936 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many AXITEC AC-285P/156-72S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AXITEC AC-285P/156-72S (285.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 458 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 604 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 750 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

All closely matched AXITEC wattages and cosmetic trims sharing the AXITEC AC-285P/156-72S architecture. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the AXITEC AC-285P/156-72S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-275P/156-72S 275.0 W 247.4 W 44.34 V 35.21 V 14.2%
AXITEC AC-280P/156-72S 280.0 W 252.0 W 44.46 V 35.39 V 14.46%
AXITEC AC-285P/156-72S 285.0 W 256.6 W 44.51 V 35.6 V 14.72%
AXITEC AC-290P/156-72S 290.0 W 261.2 W 44.65 V 35.86 V 14.98%
AXITEC AC-295P/156-72S 295.0 W 265.9 W 44.74 V 35.98 V 15.23%

How Many AXITEC AC-285P/156-72S Modules Fit in a Cold-Weather String?

Maximum series module counts for AXITEC AC-285P/156-72S from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.51V and beta_Voc=-0.349%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.5 V 11 panels 566.5 V 19 panels
-10 C (14 F) 49.95 V 12 panels 599.4 V 20 panels
0 C (32 F) 48.39 V 12 panels 580.7 V 20 panels
25 C (77 F STC) 44.51 V 13 panels 578.6 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-285P/156-72S?

Alternative CEC solar modules from competing brands near AXITEC AC-285P/156-72S (285.0 W), including Gintung Energy ASEC-285G6M. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-285G6M
Gintung Energy
285.0 W Tie (0 W) 44.53 V 14.57% 89.5%
Gintung Energy ASEC-285G6S
Gintung Energy
285.0 W Tie (0 W) 44.69 V 14.57% 89.7%
Centrosolar America DP72 285
Centrosolar America
285.0 W Tie (0 W) 44.32 V 14.66% 88.5%
BYD Company Limited BYD 285P6C-36
BYD Company Limited
285.0 W Tie (0 W) 44.3 V 14.69% 91.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-285P/156-72S?

Evaluate AXITEC AC-285P/156-72S (285.0 W STC, 44.51 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-285P/156-72S reaches 51.5 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 604 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (604 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-285P/156-72S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-285P/156-72S 8 kW Residential Fit

Needs 29 modules (604 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Gintung Energy ASEC-285G6M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 256.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-285P/156-72S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

Why is AXITEC AC-285P/156-72S PTC wattage (256.6 W) lower than STC (285.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 256.6 W PTC (90.0% retention) across AXITEC AC-285P/156-72S's 1.936 m2 aperture.

Who should skip AXITEC AC-285P/156-72S on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 29 AXITEC AC-285P/156-72S panels (604 sq ft) leave unusable roof gaps vs. Gintung Energy ASEC-285G6M.

What is the 1,000 V commercial string limit for AXITEC AC-285P/156-72S?

On 1,000 V commercial inverters at -10 C (49.95 V cold Voc), AXITEC AC-285P/156-72S fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AXITEC AC-285P/156-72S.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.