Skip to main content
WireAndSun
Calculators
CEC PV Module

Shanghai ST Solar STM335-130 — CEC Solar Module Specifications

Manufacturer: Shanghai ST Solar Registry: CEC Verified Engineering Specification

Shanghai ST Solar STM335-130 is a 335.0 W STC (299.1 W PTC) Mono-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 14.76% efficiency, 81.25 V Voc at 25 C, and 90.92 V cold Voc at -10 C (6 panels max per 600 V string).

STC Wattage
335.0 W
PTC Wattage
299.1 W
Voc @ 25C
81.25 V
Efficiency
14.76%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shanghai ST Solar STM335-130 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Shanghai ST Solar STM335-130 (Mono-c-Si) residential solar systems.

Homeowners evaluating Shanghai ST Solar STM335-130 need 18 panels for 6 kW or 24 panels (586 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (586 sq ft). Under NEC 690.7(A), beta_Voc (-0.34%/C) pushes open-circuit voltage to 90.92 V at 14 F and 93.68 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Shanghai ST Solar STM335-130 Fall Across Listed CEC Models?

Comparison of Shanghai ST Solar STM335-130 (335.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Shanghai ST Solar STM335-130 (335.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCShanghai ST Solar : 335.0 W

What Dataset Percentiles Define Shanghai ST Solar STM335-130?

Relative ranking of Shanghai ST Solar STM335-130 across nameplate watts, 89.3% PTC thermal ratio, and module aperture efficiency.

Shanghai ST Solar STM335-130 Engineering BenchmarksPercentile comparison of Shanghai ST Solar STM335-130 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage335.0 WPTC/STC Retention89.3%Module Efficiency14.76%

What Do the Dataset Ranks Show for Shanghai ST Solar STM335-130?

Summary of Shanghai ST Solar STM335-130 output rank, 8 kW array size (24 panels), efficiency rating, and 600 V string limit.

Rank #13,844 / 21,677

335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,067

14.76% Aperture Efficiency

Power density 147.6 W/m2 (5.15 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

6 Panels Max @ -10 C (600 V)

Cold Voc reaches 90.92 V at -10 C (545.5 V string) and 93.68 V at -20 C (6 max).

8 kW Reference Array

24 Panels = 8,040 W STC

Occupies 54.5 m2 (586 sq ft) producing 7,178 W PTC; NEC 690.8 OCPD floor is 8.94 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 81.25 * (1 + (-0.34/100) * (-10 - 25)) = 90.92 V | OCPD = 1.56 * 5.73 = 8.94 A

Inputs from CEC Modules.csv for Shanghai ST Solar STM335-130: Voc=81.25 V, beta_Voc=-0.34%/C, Isc=5.73 A, STC=335.0 W, Area=2.269 m2.

Result: 6 panels max on 600 V (545.5 V); 24 panels for 8 kW (586 sq ft).

What Are the Published CEC Specifications for Shanghai ST Solar STM335-130?

Complete CEC test sheet for Shanghai ST Solar STM335-130 including Isc (5.73 A), Voc (81.25 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Shanghai ST Solar STM335-130.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 335.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 299.1 W (89.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 81.25 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.73 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 65.0 V / 5.15 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.34 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.76% (2.269 m2) Array roof footprint density
Cell Count & Technology 130 cells (Mono-c-Si) Monofacial backsheet

How Many Shanghai ST Solar STM335-130 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Shanghai ST Solar STM335-130.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.03 kW 440 sq ft $1,509 $2,552
8 kW Class 24 8.04 kW 586 sq ft $2,012 $3,403
10 kW Class 30 10.05 kW 733 sq ft $2,515 $4,253

Which Sibling Wattage & Trim Variants Belong to This Shanghai ST Solar Series?

Related Shanghai ST Solar power steps and black/silver trims consolidated into this Shanghai ST Solar STM335-130 series guide.

Sibling CEC listings grouped into the Shanghai ST Solar STM335-130 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Shanghai ST Solar STM325-130 325.0 W 289.9 W 81.25 V 65.0 V 14.32%
Shanghai ST Solar STM330-130 330.0 W 294.5 W 81.25 V 65.0 V 14.54%
Shanghai ST Solar STM335-130 335.0 W 299.1 W 81.25 V 65.0 V 14.76%
Shanghai ST Solar STM340-130 340.0 W 303.7 W 81.25 V 65.0 V 14.99%
Shanghai ST Solar STM345-130 345.0 W 308.3 W 81.25 V 65.0 V 15.21%

How Many Shanghai ST Solar STM335-130 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Shanghai ST Solar STM335-130 (81.25 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=81.25V and beta_Voc=-0.34%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 93.68 V 6 panels 562.1 V 10 panels
-10 C (14 F) 90.92 V 6 panels 545.5 V 10 panels
0 C (32 F) 88.16 V 6 panels 529.0 V 11 panels
25 C (77 F STC) 81.25 V 7 panels 568.8 V 12 panels

Which Cross-Brand Solar Modules Compare Closest to Shanghai ST Solar STM335-130?

Four comparable CEC modules such as DEHUI SOLAR POWER INC DH-72P-335W (335.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DEHUI SOLAR POWER INC DH-72P-335W
DEHUI SOLAR POWER INC
335.0 W Tie (0 W) 47.8 V 17.42% 90.7%
BYD Company Limited BYD335P6K-36
BYD Company Limited
335.0 W Tie (0 W) 47.28 V 17.27% 91.8%
Auxin Solar AXN6M612T335
Auxin Solar
335.0 W Tie (0 W) 47.04 V 17.26% 91.7%
Bluesun Solar Energy Tech CoLtd BSM335P-72
Bluesun Solar Energy Tech CoLtd
335.0 W Tie (0 W) 46.76 V 17.29% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Shanghai ST Solar STM335-130?

Evaluate Shanghai ST Solar STM335-130 (335.0 W STC, 81.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Shanghai ST Solar STM335-130 reaches 93.68 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 586 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (586 sq ft).
  • 2026 tax credit baseline: cash residential installs of Shanghai ST Solar STM335-130 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Shanghai ST Solar STM335-130 8 kW Residential Fit

Needs 24 modules (586 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare DEHUI SOLAR POWER INC DH-72P-335W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 299.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Shanghai ST Solar STM335-130 by Shanghai ST Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Shanghai ST Solar STM335-130 PTC wattage (299.1 W) lower than STC (335.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 299.1 W PTC (89.3% retention) across Shanghai ST Solar STM335-130's 2.269 m2 aperture.

Who should skip Shanghai ST Solar STM335-130 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 Shanghai ST Solar STM335-130 panels (586 sq ft) leave unusable roof gaps vs. DEHUI SOLAR POWER INC DH-72P-335W.

What is the 1,000 V commercial string limit for Shanghai ST Solar STM335-130?

On 1,000 V commercial inverters at -10 C (90.92 V cold Voc), Shanghai ST Solar STM335-130 fits up to 10 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Shanghai ST Solar STM335-130.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.