Shanghai ST Solar STM335-130 is a 335.0 W STC (299.1 W PTC) Mono-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 14.76% efficiency, 81.25 V Voc at 25 C, and 90.92 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 335.0 W
- PTC Wattage
- 299.1 W
- Voc @ 25C
- 81.25 V
- Efficiency
- 14.76%
How Does Shanghai ST Solar STM335-130 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Shanghai ST Solar STM335-130 (Mono-c-Si) residential solar systems.
Homeowners evaluating Shanghai ST Solar STM335-130 need 18 panels for 6 kW or 24 panels (586 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (586 sq ft). Under NEC 690.7(A), beta_Voc (-0.34%/C) pushes open-circuit voltage to 90.92 V at 14 F and 93.68 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Shanghai ST Solar STM335-130 Fall Across Listed CEC Models?
Comparison of Shanghai ST Solar STM335-130 (335.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Shanghai ST Solar STM335-130?
Relative ranking of Shanghai ST Solar STM335-130 across nameplate watts, 89.3% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Shanghai ST Solar STM335-130?
Summary of Shanghai ST Solar STM335-130 output rank, 8 kW array size (24 panels), efficiency rating, and 600 V string limit.
335.0 W STC · Higher Than 34.7%
335.0 W STC (-50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
14.76% Aperture Efficiency
Power density 147.6 W/m2 (5.15 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 90.92 V at -10 C (545.5 V string) and 93.68 V at -20 C (6 max).
24 Panels = 8,040 W STC
Occupies 54.5 m2 (586 sq ft) producing 7,178 W PTC; NEC 690.8 OCPD floor is 8.94 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 81.25 * (1 + (-0.34/100) * (-10 - 25)) = 90.92 V | OCPD = 1.56 * 5.73 = 8.94 A
Inputs from CEC Modules.csv for Shanghai ST Solar STM335-130: Voc=81.25 V, beta_Voc=-0.34%/C, Isc=5.73 A, STC=335.0 W, Area=2.269 m2.
Result: 6 panels max on 600 V (545.5 V); 24 panels for 8 kW (586 sq ft).
What Are the Published CEC Specifications for Shanghai ST Solar STM335-130?
Complete CEC test sheet for Shanghai ST Solar STM335-130 including Isc (5.73 A), Voc (81.25 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 335.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 299.1 W (89.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 81.25 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 5.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 65.0 V / 5.15 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.76% (2.269 m2) | Array roof footprint density |
| Cell Count & Technology | 130 cells (Mono-c-Si) | Monofacial backsheet |
How Many Shanghai ST Solar STM335-130 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Shanghai ST Solar STM335-130.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.03 kW | 440 sq ft | $1,509 | $2,552 |
| 8 kW Class | 24 | 8.04 kW | 586 sq ft | $2,012 | $3,403 |
| 10 kW Class | 30 | 10.05 kW | 733 sq ft | $2,515 | $4,253 |
Which Sibling Wattage & Trim Variants Belong to This Shanghai ST Solar Series?
Related Shanghai ST Solar power steps and black/silver trims consolidated into this Shanghai ST Solar STM335-130 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Shanghai ST Solar STM325-130 | 325.0 W | 289.9 W | 81.25 V | 65.0 V | 14.32% |
| Shanghai ST Solar STM330-130 | 330.0 W | 294.5 W | 81.25 V | 65.0 V | 14.54% |
| Shanghai ST Solar STM335-130 | 335.0 W | 299.1 W | 81.25 V | 65.0 V | 14.76% |
| Shanghai ST Solar STM340-130 | 340.0 W | 303.7 W | 81.25 V | 65.0 V | 14.99% |
| Shanghai ST Solar STM345-130 | 345.0 W | 308.3 W | 81.25 V | 65.0 V | 15.21% |
How Many Shanghai ST Solar STM335-130 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Shanghai ST Solar STM335-130 (81.25 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 93.68 V | 6 panels | 562.1 V | 10 panels |
| -10 C (14 F) | 90.92 V | 6 panels | 545.5 V | 10 panels |
| 0 C (32 F) | 88.16 V | 6 panels | 529.0 V | 11 panels |
| 25 C (77 F STC) | 81.25 V | 7 panels | 568.8 V | 12 panels |
Which Cross-Brand Solar Modules Compare Closest to Shanghai ST Solar STM335-130?
Four comparable CEC modules such as DEHUI SOLAR POWER INC DH-72P-335W (335.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| DEHUI SOLAR POWER INC DH-72P-335W DEHUI SOLAR POWER INC |
335.0 W | Tie (0 W) | 47.8 V | 17.42% | 90.7% |
| BYD Company Limited BYD335P6K-36 BYD Company Limited |
335.0 W | Tie (0 W) | 47.28 V | 17.27% | 91.8% |
| Auxin Solar AXN6M612T335 Auxin Solar |
335.0 W | Tie (0 W) | 47.04 V | 17.26% | 91.7% |
| Bluesun Solar Energy Tech CoLtd BSM335P-72 Bluesun Solar Energy Tech CoLtd |
335.0 W | Tie (0 W) | 46.76 V | 17.29% | 91.4% |
What Are the Design Limits and Best-Fit Uses for Shanghai ST Solar STM335-130?
Evaluate Shanghai ST Solar STM335-130 (335.0 W STC, 81.25 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Shanghai ST Solar STM335-130 reaches 93.68 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 586 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (586 sq ft).
- 2026 tax credit baseline: cash residential installs of Shanghai ST Solar STM335-130 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Shanghai ST Solar STM335-130 8 kW Residential Fit
Needs 24 modules (586 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare DEHUI SOLAR POWER INC DH-72P-335W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 299.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Shanghai ST Solar STM335-130 by Shanghai ST Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Shanghai ST Solar STM335-130 PTC wattage (299.1 W) lower than STC (335.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 299.1 W PTC (89.3% retention) across Shanghai ST Solar STM335-130's 2.269 m2 aperture.
Who should skip Shanghai ST Solar STM335-130 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 Shanghai ST Solar STM335-130 panels (586 sq ft) leave unusable roof gaps vs. DEHUI SOLAR POWER INC DH-72P-335W.
What is the 1,000 V commercial string limit for Shanghai ST Solar STM335-130?
On 1,000 V commercial inverters at -10 C (90.92 V cold Voc), Shanghai ST Solar STM335-130 fits up to 10 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Shanghai ST Solar STM335-130.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)