Skip to main content
WireAndSun
Calculators
CEC PV Module

Gintung Energy ASEC-260G6M — CEC Solar Module Specifications

Manufacturer: Gintung Energy Registry: CEC Verified Engineering Specification

Gintung Energy ASEC-260G6M is a 260.0 W STC (232.1 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 13.29% efficiency, 43.84 V Voc at 25 C, and 48.9 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
232.1 W
Voc @ 25C
43.84 V
Efficiency
13.29%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gintung Energy ASEC-260G6M Compare Against Peer CEC Listings?

Solar engineering breakdown for Gintung Energy ASEC-260G6M: PTC thermal retention, roof footprint, and cold Voc string bounds. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Measured at 260.0 W STC and 232.1 W PTC, Gintung Energy ASEC-260G6M sits -125.0 W vs all-CEC median (below all-CEC median; higher than 10.4% of peers) among 21,677 listed modules. Power density reaches 132.9 W/m2 (6.62 percentage points below 19.91% CEC median). Mid-range 43.84 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer CSI Solar Co Ltd CS6X-265P rates 265.0 W.

Where Does Gintung Energy ASEC-260G6M Fall Across Listed CEC Models?

Distribution marker showing Gintung Energy ASEC-260G6M (260.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Gintung Energy ASEC-260G6M (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGintung Energy ASE: 260.0 W

What Dataset Percentiles Define Gintung Energy ASEC-260G6M?

Dataset percentiles tracking Gintung Energy ASEC-260G6M power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Gintung Energy ASEC-260G6M Engineering BenchmarksPercentile comparison of Gintung Energy ASEC-260G6M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention89.3%Module Efficiency13.29%

What Do the Dataset Ranks Show for Gintung Energy ASEC-260G6M?

Benchmark highlights for Gintung Energy ASEC-260G6M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #21,324

13.29% Aperture Efficiency

Power density 132.9 W/m2 (6.62 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.9 V at -10 C (586.8 V string) and 50.35 V at -20 C (11 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 60.6 m2 (653 sq ft) producing 7,195 W PTC; NEC 690.8 OCPD floor is 12.5 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.84 * (1 + (-0.33/100) * (-10 - 25)) = 48.9 V | OCPD = 1.56 * 8.01 = 12.5 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-260G6M: Voc=43.84 V, beta_Voc=-0.33%/C, Isc=8.01 A, STC=260.0 W, Area=1.956 m2.

Result: 12 panels max on 600 V (586.8 V); 31 panels for 8 kW (653 sq ft).

What Are the Published CEC Specifications for Gintung Energy ASEC-260G6M?

Official CEC datasheet figures for Gintung Energy ASEC-260G6M (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-260G6M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 232.1 W (89.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.84 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.01 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.53 V / 7.53 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.33 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.29% (1.956 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Gintung Energy ASEC-260G6M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Gintung Energy ASEC-260G6M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 505 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 653 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 821 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

Consolidated Gintung Energy wattage variants sharing the Gintung Energy ASEC-260G6M mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Gintung Energy ASEC-260G6M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Gintung Energy ASEC-250G6M 250.0 W 223.0 W 43.53 V 34.3 V 12.78%
Gintung Energy ASEC-255G6M 255.0 W 227.5 W 43.69 V 34.46 V 13.04%
Gintung Energy ASEC-260G6M 260.0 W 232.1 W 43.84 V 34.53 V 13.29%
Gintung Energy ASEC-265G6M 265.0 W 236.7 W 43.99 V 34.65 V 13.55%
Gintung Energy ASEC-270G6M 270.0 W 241.3 W 44.15 V 34.87 V 13.8%

How Many Gintung Energy ASEC-260G6M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Gintung Energy ASEC-260G6M (48.9 V at 14 F).

Computed from Voc=43.84V and beta_Voc=-0.33%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.35 V 11 panels 553.9 V 19 panels
-10 C (14 F) 48.9 V 12 panels 586.8 V 20 panels
0 C (32 F) 47.46 V 12 panels 569.5 V 21 panels
25 C (77 F STC) 43.84 V 13 panels 569.9 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-260G6M?

Competing CEC solar panels closest to Gintung Energy ASEC-260G6M in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS6X-265P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6X-265P
CSI Solar Co Ltd
265.0 W +5.0 W 43.9 V 14.31% 88.8%
Advance Power API-P265
Advance Power
265.0 W +5.0 W 43.27 V 13.58% 89.1%
Auxin Solar AXN6P610T265
Auxin Solar
265.0 W +5.0 W 43.27 V 13.58% 89.1%
BYD Company Limited BYD 265P6C-36
BYD Company Limited
265.0 W +5.0 W 43.11 V 13.66% 90.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-260G6M?

Evaluate Gintung Energy ASEC-260G6M (260.0 W STC, 43.84 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-260G6M reaches 50.35 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 653 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (653 sq ft).
  • 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-260G6M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Gintung Energy ASEC-260G6M 8 kW Residential Fit

Needs 31 modules (653 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS6X-265P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 232.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-260G6M by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

How many Gintung Energy ASEC-260G6M panels fit on a 600 V winter solar string?

At -10 C (14 F), Gintung Energy ASEC-260G6M cold Voc rises from 43.84 V to 48.9 V (beta_Voc -0.33%/C), capping a 600 V string at 12 panels (586.8 V).

How much roof area does an 8 kW array of Gintung Energy ASEC-260G6M need?

An 8 kW DC system uses 31 Gintung Energy ASEC-260G6M modules (8,060 W STC / 7,195 W PTC), covering roughly 653 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does Gintung Energy ASEC-260G6M compare against CSI Solar Co Ltd CS6X-265P?

Gintung Energy ASEC-260G6M outputs 260.0 W STC (43.84 V Voc, rank #19,146 of 21,677), while CSI Solar Co Ltd CS6X-265P delivers 265.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.