PEIMAR SM310M (FB) is a 310.0 W STC (285.8 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 19.02% efficiency, 40.94 V Voc at 25 C, and 45.0 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 285.8 W
- Voc @ 25C
- 40.94 V
- Efficiency
- 19.02%
How Does PEIMAR SM310M (FB) Compare Against Peer CEC Listings?
How PEIMAR PEIMAR SM310M (FB) handles rooftop heat (285.8 W PTC), 8 kW sizing, and cold winter string voltage.
PEIMAR builds the PEIMAR SM310M (FB) (Mono-c-Si) as a compact residential or specialty off-grid module delivering 190.2 W/m2 (0.89 percentage points below 19.91% CEC median). Compared against Auxin Solar AXN6M610T310 (310.0 W), this model holds strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677). Mid-range 40.94 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 15.27 A overcurrent floor served by a 20 A breaker.
Where Does PEIMAR SM310M (FB) Fall Across Listed CEC Models?
Where PEIMAR SM310M (FB) (310.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define PEIMAR SM310M (FB)?
Percentile placement of PEIMAR SM310M (FB) across power density (190.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for PEIMAR SM310M (FB)?
Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SM310M (FB) specifications. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.02% Aperture Efficiency
Power density 190.2 W/m2 (0.89 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.0 V at -10 C (585.0 V string) and 46.15 V at -20 C (13 max).
26 Panels = 8,060 W STC
Occupies 42.4 m2 (456 sq ft) producing 7,431 W PTC; NEC 690.8 OCPD floor is 15.27 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.94 * (1 + (-0.283/100) * (-10 - 25)) = 45.0 V | OCPD = 1.56 * 9.79 = 15.27 A
Inputs from CEC Modules.csv for PEIMAR SM310M (FB): Voc=40.94 V, beta_Voc=-0.283%/C, Isc=9.79 A, STC=310.0 W, Area=1.63 m2.
Result: 13 panels max on 600 V (585.0 V); 26 panels for 8 kW (456 sq ft).
What Are the Published CEC Specifications for PEIMAR SM310M (FB)?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SM310M (FB).
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 285.8 W (92.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.94 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.79 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.55 V / 9.25 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.283 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.02% (1.63 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many PEIMAR SM310M (FB) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SM310M (FB) (310.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 351 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 456 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 579 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?
All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR SM310M (FB) architecture. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PEIMAR SM300M (FB) | 300.0 W | 276.3 W | 40.45 V | 33.15 V | 18.4% |
| PEIMAR SM305M (FB) | 305.0 W | 281.0 W | 40.7 V | 33.35 V | 18.71% |
| PEIMAR SM310M (FB) | 310.0 W | 285.8 W | 40.94 V | 33.55 V | 19.02% |
| PEIMAR SM315M (FB) | 315.0 W | 290.5 W | 41.18 V | 33.75 V | 19.33% |
| PEIMAR SM320M (FB) | 320.0 W | 295.3 W | 41.42 V | 33.95 V | 19.63% |
How Many PEIMAR SM310M (FB) Modules Fit in a Cold-Weather String?
Maximum series module counts for PEIMAR SM310M (FB) from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.15 V | 13 panels | 599.9 V | 21 panels |
| -10 C (14 F) | 45.0 V | 13 panels | 585.0 V | 22 panels |
| 0 C (32 F) | 43.84 V | 13 panels | 569.9 V | 22 panels |
| 25 C (77 F STC) | 40.94 V | 14 panels | 573.2 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to PEIMAR SM310M (FB)?
Alternative CEC solar modules from competing brands near PEIMAR SM310M (FB) (310.0 W), including Auxin Solar AXN6M610T310. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M610T310 Auxin Solar |
310.0 W | Tie (0 W) | 41.14 V | 19.05% | 91.8% |
| CertainTeed CT310M11-02 CertainTeed |
310.0 W | Tie (0 W) | 41.14 V | 19.68% | 91.4% |
| DualSun SAS DualSun 310M-60-00 DualSun SAS |
310.0 W | Tie (0 W) | 40.3 V | 18.9% | 91.4% |
| Bluesun Solar Energy Tech CoLtd BSM310M-60 Bluesun Solar Energy Tech CoLtd |
310.0 W | Tie (0 W) | 40.18 V | 19.02% | 91.9% |
What Are the Design Limits and Best-Fit Uses for PEIMAR SM310M (FB)?
Evaluate PEIMAR SM310M (FB) (310.0 W STC, 40.94 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SM310M (FB) reaches 46.15 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 456 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (456 sq ft).
- 2026 tax credit baseline: cash residential installs of PEIMAR SM310M (FB) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PEIMAR SM310M (FB) 8 kW Residential Fit
Needs 26 modules (456 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Auxin Solar AXN6M610T310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 285.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PEIMAR SM310M (FB) by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for PEIMAR SM310M (FB)?
Multiplying PEIMAR SM310M (FB)'s 9.79 A short-circuit current by 1.56 equals 15.27 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can PEIMAR SM310M (FB) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.0 V cold Voc at 14 F and handles 9.79 A Isc; string inverters cap PEIMAR SM310M (FB) at 13 panels on 600 V.
Is PEIMAR SM310M (FB) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SM310M (FB) rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.